Thrombite™ Clot Retriever Device
More efficient choice of recanalization
HELICAL OPEN-SIDE STRUCTURE
HIGHER ACUTE RECANALIZATION RATE
The Thrombite™ Clot RetrieverDevice, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.
PRODUCT FEATURES
HELICAL OPEN-SIDE STRUCTURE
enables Thrombite™ retriever to efficiently entwine and clamp the clot
assures clot retention for confident removal and revascularization
OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE
increases contact surface with thrombus and maximizes clot integration
EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION
optimizes clot retention during smooth navigation through the tortuous anatomies
RADIAL FORCE
High radial force is designed for clot integration at the initial stage of stent expansion
Low radial force at nominal stent diameter ensures atraumatic retrieval
RADIAL FORCE
How a Stent Retriever Procedure Is Performed
Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body.
INDICATIONS
Thrombite™ Clot Retriever Device
The Thrombite™ clot retrieval deviceis intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.
Zyloxton-bridgeprovides endovascular clot retrieval devices, stent retriever devices, clot retrieval, stent retrieval device, etc. Want to know more, contact us.
在线联系供应商
Other supplier products
Thrombite™ Clot Retriever Device | More efficient choice of recanalization HELICAL OPEN-SIDE STRUCTURE HIGHER ACUTE RECANALIZATION RATE The Thrombite™ Clot RetrieverDevice... | |
Drug Coated PTA Balloon Catheter | OVERVIEW Drug Coated PTA Balloon Catheter ENSURE EFFECTIVE DRUG DELIVERY OF A SAFE THERAPEUTIC DOSAGE The Drug-Coated PTA Balloon Catheter, a ve... | |
Aneurysm Coils | OVERVIEW Aneurysm Coils The Ton-Bridge super soft coils are the neurovascular embolization coilsdesigned for the embolization of intracranial ane... | |
PTA Balloon Catheter | EASY ACCESS TO THE MOST CHALLENGING ANATOMIES The Percutaneous Transluminal Angioplasty (PTA) Balloon Catheters are non-reusable semi-compliant co... | |
Glycine™ Microcatheter for Clot Retriever | OVERVIEW Glycine™ Microcatheter for Clot Retriever Designed to provide smooth navigation and ensure accurate deployment of devices PRODU... |
Same products
Blue Non-Woven Fabric Silicone Gel Tape Roll for Scar Treatment | 卖方: Zhejiang Hangbiao Medical Supplies Co., Ltd. | Surgical Tape Factory() Blue Non-Woven Fabric Silicone Gel Tape Roll is a premium scar repair pro... | |
MECHANIC MEC 4K 2K 高清电子目镜相机,适用于立体显微镜 | 卖方: 深圳市维客修科技有限公司 | 描述 美卡尼克MEC 2K/2K PRO/4K高清电子目镜摄像机,可以将双目立体显微镜改装成三目显微镜。采用SONY 1/2.3"进口CMOS传感器,采用优质CMOS传感器,硬... | |
Fluke 15B+ 17B+ 18B+ 数字万用表电压频率测试仪 | 卖方: 深圳市维客修科技有限公司 | iFixes 10CC半透明/全透明/乳白色/浅无铅助焊膏适用于手机主板CPU BGA维修。iFixes助焊剂注射器注射焊膏焊接膏手机整理焊接耗材系列,适用于电路板纳米芯片,手机PCB, SMT... | |
Grey Rubber Stopper For Blood Collection Tube | 卖方: Taizhou KangLong Medical Treatment Technology Co., Ltd. | Medical Grey Rubber Stopper For Blood Collection Tube Good formulation technology guarantees... | |
HTT-02 Hot Tack Tester | 卖方: Cell Instruments Co., Ltd | The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren... |