Thrombite™ Clot Retriever Device
More efficient choice of recanalization
HELICAL OPEN-SIDE STRUCTURE
HIGHER ACUTE RECANALIZATION RATE
The Thrombite™ Clot RetrieverDevice, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.
PRODUCT FEATURES
HELICAL OPEN-SIDE STRUCTURE
enables Thrombite™ retriever to efficiently entwine and clamp the clot
assures clot retention for confident removal and revascularization
OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE
increases contact surface with thrombus and maximizes clot integration
EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION
optimizes clot retention during smooth navigation through the tortuous anatomies
RADIAL FORCE
High radial force is designed for clot integration at the initial stage of stent expansion
Low radial force at nominal stent diameter ensures atraumatic retrieval
RADIAL FORCE
How a Stent Retriever Procedure Is Performed
Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body.
INDICATIONS
Thrombite™ Clot Retriever Device
The Thrombite™ clot retrieval deviceis intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.
Zyloxton-bridgeprovides endovascular clot retrieval devices, stent retriever devices, clot retrieval, stent retrieval device, etc. Want to know more, contact us.
在线联系供应商
Other supplier products
Thrombite™ Clot Retriever Device | More efficient choice of recanalization HELICAL OPEN-SIDE STRUCTURE HIGHER ACUTE RECANALIZATION RATE The Thrombite™ Clot RetrieverDevice... | |
Drug Coated PTA Balloon Catheter | OVERVIEW Drug Coated PTA Balloon Catheter ENSURE EFFECTIVE DRUG DELIVERY OF A SAFE THERAPEUTIC DOSAGE The Drug-Coated PTA Balloon Catheter, a ve... | |
Peripheral Stent System | OVERVIEW Peripheral Stent System The ZENFLEX® Peripheral Stent System is designed to deliver a self-expanding stent to the iliac artery, supe... | |
Matador Distal Access Guiding Catheter | OVERVIEW Matador Distal Access Catheter 95cm/105cm/115cm Working Lengths ”/0.078” inner lumen allows for multiple devices 8... | |
HEALTHCARE PROFESSIONALS Explore our medical solutions | TONBRIDGE DIALOGUE Focus on the latest points in the neurological intervention field with the help of the media platform in neurological intervent... |
Same products
Grey Rubber Stopper For Blood Collection Tube | 卖方: Taizhou KangLong Medical Treatment Technology Co., Ltd. | Medical Grey Rubber Stopper For Blood Collection Tube Good formulation technology guarantees... | |
HTT-02 Hot Tack Tester | 卖方: Cell Instruments Co., Ltd | The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren... | |
SPC-01 Stretch Film Peeling Cling Tester | 卖方: Cell Instruments Co., Ltd | The SPC-01 Stretch Film Peeling Cling Testermeasures the adhesion between two layers of stretch f... | |
FTT-01 Film Thickness Tester | 卖方: Cell Instruments Co., Ltd | The FTT-01 FilmThickness Testerutilizes a mechanical scanning technique to measure the thickness ... | |
TST-01 Tensile Tester | 卖方: Cell Instruments Co., Ltd | TST-01 tensile testers are suitable for conducting a variety of tests, including tensile strength... |