.

Polyester braided suture with needle Ethibond Polyester suture

Maximum security in approximation of tissues under stress conditions permanent support. Silicone coating minimize tissue drag and sawing. Smooth passage through tissue. Unsurpassed strength in critical wound healing. Excellent suture handling and trying. Suture with highly uniform diameter. Sterilised by Cr-60 Radiation. Confirms to the specifications of United States Pharmacopoeia (U.S.P.) DESCRIPTIONNeedle description:304 ss or 420J2 stainless steel are.They are made from tempered surgical steel to ensure strength and durability, as well as to resist corrosion. used in medical procedures for wound closure. All suture needles are strong and extremely sharp. As a leading suture needle manufacture in china, we supply different needlesEnd Type: drilled, rolled, regular, spring and spring doubleShapes: 1/2 circle, 3/8circle, 5/8 circle, J shape, compound curve, 1/4 circle,1/2 curved and straight.Point shape: taper cutting, curved reverse cutting, curved cutting, round bodied, blunt, spatular curved and conventional.Thread description: Polyester suture is a nonabsorbable, braided, sterile, surgical suture composed of Poly (ethylene terephthalate). It is prepared from fibers of high molecular weight, long-chain,linear polyesters having recurrent aromatic rings as an integral component. Polyester sutures are braided for optimal handling properties, and for good visibility in the surgical field, are dyed green.INDICATIONSPolyester suture is indicated for use in general soft tissue approximation and/or ligation,including use in cardiovascular, ophthalmic and neurological procedures.ACTIONSPolyester suture elicits a minimal acute inflammatory reaction in tissue, followed by a gradual encapsulation of the suture by fibrous connective tissue. Implantation studies in animals show no meaningful decline in polyester suture strength over time. The polyester fiber suture material is pharmacologically inactive.CONTRAINDICATIONSNone known.WARNINGSUsers should be familiar with surgical procedures and techniques involving nonabsorbable sutures before employing Ployester suture for wound closure, as risk of wound dehiscence may vary with the site of application and the suture material used.Do not resterilize. Discard opened packages and unused sutures.As with any foreign body, prolonged contact of any suture with salt solutions, such as thosefound in the urinary or biliary tracts, may result in calculus formation. Acceptable surgical practice should be followed for the management of infected or contaminated wounds.PRECAUTIONSIn handling this or any other suture material, care should be taken to avoid damage from handling. Avoid crushing or crimping damage due to application of surgical instruments such as forceps or needle holders. The use of additional throws is particularly appropriate when knotting monofilament sutures.As with any suture material, adequate knot security requires the accepted surgical technique of flat and square ties, with additional throws as warranted by surgical circumstance and the experience of the surgeon.To avoid damaging needle points and swage areas, grasp the needle in an area one-third (1/3) to one-half (1/2) of the distance from the swaged end to the point. Reshaping needles may cause them to lose strength and be less resistant to bending and breaking. Users should exercise caution when handling surgical needles to avoid inadvertent needle sticks. Discard used needles in "sharps" containers.ADVERSE REACTIONSAdverse effects associated with the use of this device include wound dehiscence, calcul information in urinary and biliary tracts when prolonged contact with salt solutions such as urine and bile occurs, infection, minimal acute inflammatory tissue reaction and transitory local irritation at the wound site. Broken needles may result in extended or additional surgeries or residual foreign bodies. Inadvertent needle sticks with contaminated surgical needles may result in the transmission of bloodborne pathogens.HOW SUPPLIEDPolyester sutures are available as sterile, braided, green and undyed (white) strands in sizes 6-0 through 5 (metric sizes 0.7-7) in a variety of lengths, with and without permanently attached needles.Polyester sutures are also available in green monofilament in U.S.P. sizes 10-0 and 11-0(metric sizes 0.2-0.1).Polyester sutures, green, braided in U.S.P. size 0 (metric size 3.5)are also available attached to CONTROL RELEASE removable needles.Polyester sutures are available in one, two and three dozen boxes.

Send product request

To: Huaian Haoyang International Trading Co.,Ltd
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Poliglecaprone suture with needle PGCL suture
Poliglecaprone suture with needle PGCL suture Manufactured by modern technology and made of high quality gut of healthy Chinese goats The body of the suture is smooth, causing no cap...
non absorbable Nylon sutures with needle
non absorbable Nylon sutures with needle Excellent security with snug and flattened knots, Minimal memory. Flexible easy to handle and tie Smooth passage through tissue. Unsurpass...
polyglycolic acid suture with needle PGA sutures
polyglycolic acid suture with needle PGA sutures 1. Synthetic, non-homologous protein, good biocompatibility, the very lowly reaction, and optimum wound healing. 2. Multi-strand woven, stron...
Silk (Braided) nonabsorbable suture black braidd silk sutures surgical silk suture
Silk (Braided) nonabsorbable suture black braidd silk sutures surgical silk suture Made of high quality cocoons of Chinese silk worm, manufactured by modern technology, a special degumming purification process to obtain high elas...
Carbon or Steel Surgical Blades and Scalpels
Carbon or Steel Surgical Blades and Scalpels Detailed introduction to surgical blade: surgical blade: Use: This product is used for the basic surgical surgery for cutting soft tissues. Mate...
All supplier products

Same products

Medical Disposable Iv Infusion Set Iv Drip Set
Medical Disposable Iv Infusion Set Iv Drip Set Seller: Hebei Zongkai Technology Co., LTD Customization options Customized logo(Min. order: 100000 units) Customize...
Air Permeability Tester STD- F8
Air Permeability Tester STD- F8 Seller: Standard International Group (HK) Limited The Air Permeability Tester is designed to quickly and accurately measure the breathability and p...
Surface Performance Tester STD-FB4 - A
Surface Performance Tester STD-FB4 - A Seller: Standard International Group (HK) Limited Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti...
Compression Tester STD - FB3 - A
Compression Tester STD - FB3 - A Seller: Standard International Group (HK) Limited TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar...
Single - Strand Bending Tester STD - FB2 - SH
Single - Strand Bending Tester STD - FB2 - SH Seller: Standard International Group (HK) Limited Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ...