Qinsun Dry Cleaning and Washing Cylinder

Dry Cleaning and Washing Cylinder, to determine color fastness to drycleaning and chlorinated pool water(AATCC 162), and applied to prepare samples for flammability testing of standard 16CFR-1610. Dry Cleaning and Washing Cylinder complies with AATCC 162, 16CFR-Part1610, etc.
Dry cleaning and washing cylinder is designed to determine the color fastness for the dry cleaning and chlorinated pool water, with the aim to prepare samples for flammability testing.
Standards
AATCC 162 Colorfastness to water: Chlorinated pool.
16CFR PART 1610 Standard for the flammability of clothing textiles.
Operation
● Clean the dry cleaning cylinder
● prepare the hardness concentrates according to the relevant standards.
● 51 ml of the hardness concentrate was diluted to 5100 ml with distilled or deionized water.
● If necessary, adjust the pH of the solution to 7.0 with sodium carbonate or acetic acid.
● 5000 ml of the solution (made in the above 3) was charged into a dry-cleaning cylinder. The temperature was adjusted to 21 ° C.
● Put the color test sample with the standard test fiber into the cylinder, turn off the barrel, and roll for 60 minutes.
● Get out the sample and remove the excess solution.
Technical Parameters
Items Parameters
Dimension 72L X 49W X 62H (cm)
Structure Stainless steel
Surface treatment Wiredrawing treatment
Transport weight 80kg
Power supply 220V 50HZ max.0.05A
Other supplier products
|
|
MK2 fiber impurity analyzer |
Fiber Impurity Analyzer / MK2 Fiber Impurity Analyzer is a special instrument for measuring the impurity content of fiber. It is mainly used to det... |
|
|
Dry penetration tester |
Dry penetration tester is designed to determine the properties of the material on the dry matter in the size of the human body dander.Standards com... |
|
|
Oxygen Index Test Apparatus |
(Limiting)OxygenIndexTestApparatusTestingStandards:ISO4589-2,ASTMD2863,GB/T2406,GB/T5454Applications:ThisOxygen Index Testerisusedtodeterminethelow... |
|
|
Average Particle Size Analyzer |
The Average Particle Size Analyzer has a simple, fast and reliable technique for measuring average particle size. This measurement can not be easil... |
|
|
Medical Face Mask Air Exchange Pressure Difference Tester |
Products meet the standard requirements, which is YY0469-2004 "Medical surgical mask technical requirements" and YY 0969-2013 "Disposable medical m... |
All supplier products
Same products