EMI Receiver System
EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for theEMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meetsCISPR15:2018,CISPR16-1,GB17743, FCC,EN55015and EN55022.
System Configurations:
• EMI-9KC Test System includes: EMI-9KC EMI Receiver built-in Attenuator (9K-1GHz), LISN-A Artificial Network Power (16A with RS-232 communicate), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers and cables.
• EMI-9KB Test System includes: EMI-9KB EMI Receiver (9K-300MHz), LISN-A Artificial Network Power (5A), CDNE-M316 Coupling/Decoupling Network for Emission, 3pcs Isolation Transformers, Attenuator and cables.
• EMI-9KA Test System includes: EMI-9KA EMI Receiver (9K-30MHz), LISN-A Artificial Network Power (5A), 3pcs Isolation Transformers, Attenuator and cables.
Option instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers:
•LISUN LSP-500VARC/LSP-1KVARC Pure Sine Wave AC Power Sourcefor EUT
•LISUN SDR-2000B Magnetic Shielding Cabinetfor the EMI Receiver System
•LISUN VVLA-30M Three Loop Antennato test 9k-30MHz Radiation
•LISUN AB-CLP Absorbing Clampto test the Home Applications & motor tools
Specification:
• Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA)
• Frequency stability: 1×10^-6
• Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz
• Test Tolerance: ±2 dB
• Measure and Detection method: PK, QP and AV
• Measure range from 20dBμV to 140dBμV
• Frequency scanning step length: 20Hz~2MHz
• Sweep bandwidth: 200Hz; 9kHz; 120kHz
• Connect PC via USB cable and software can run on Win7, Win8 and Win10, Win11
What is EMI receiver?
Electromagnetic Interference (EMI receiver) is electronic noise that interferes with cable signals and reduces signal integrity. EMI Receiver is usually generated by electromagnetic radiation sources such as motors and machines. EMI Receiver (Electromagnetic Interference) has two types: conducted interference and radiated interference. Conducted interference refers to the coupling (interference) of signals on one electrical network to another electrical network through a conductive medium. Radiated interference refers to the interference source coupling (interference) its signal to another electrical network through space.
How to test EMI Interference?
Electromagnetic disturbance that degrades the performance of electrical equipment or electronic device, works abnormally or fails. It can be divided into conducted interference test and radiated interference test. LISUN EMI-9KB is an automatic EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. It can do both conducted interference test and radiated interference test.
What's the difference between EMI and EMS?
EMC (ElectroMagneticCompatibility) literally translates to "electromagnetic compatibility". EMI (ElectromagneticInterference) "Electromagnetic Interference" can be understood as attack type. There are two types of EMI, conducted interference and radiated interference. EMS (ElectroMagneticSusceptibility) literally translates to "electromagnetic sensitivity", which we can understand as defensive type, which means the ease of performance degradation due to electromagnetic energy.
Noted: According to latestCISPR15:2018standard, you need to use CDNE-M316 (Coupling/Decoupling Network for Emission) to instead the CDN. The CDNE-M316 worked with EMI receiver system is equivalent to test radiated electromagnetic disturbance of electric lighting appliance with frequency from 30M-300mH
Send product request
Other supplier products
High Precision Rotation Luminaire Goniophotometer | What is goniophotometer definition? LSG-1890B/LSG-1800Agoniophotometeris automatic goniophotometric instrument for luminous intensity distribution... | |
Lamp Start, Run-up time and Flicker Test | LSRF-3 Lamp start, Run-up time and Light Flickering Analyzer - Flicker Tester is equipped with Class A fast photometric probe, so the sampling spee... | |
Portable CCD LED Colorimeter Spectroradiometer | The Portable CCD LED Colorimeter Spectroradiometer has the following versions which can measure different parameters: LISUN Model Functio... | |
High Precision Rotation Luminaire Goniospectroradiometer | LSG-1890BCCD/LSG-1800ACCD goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measur... | |
High Voltage Lightning Surge Generator | The SG61000-5 fully automaticsurge generator(also called lightning surge immunity test, combination wave generator, surge current generator/surge v... |
Same products
MECHANIC MEC 4K 2K HD Electronic Eyepiece Camera for Stereo Microscope | Seller: SHENZHEN PHONEFIX TECHNOLOGY CO.,LTD (CHINA PHONEFIX) | Description Mechanic MEC 2K/2K PRO/4K HD Electronic Eyepiece Camera can convert a Binocu... | |
Fluke 15B+ 17B+ 18B+ Digital Multimeter Voltage Frequency Tester | Seller: PHONEFIX technology Co.,Ltd | iFixes 10CC半透明/全透明/乳白/浅黄色无铅焊膏适用于手机主板CPU BGA维修。iFixes Solder Flux注射器注射焊膏焊膏手机修整焊接耗材系列,适用于电路板纳米芯片、手机... | |
HTT-02 Hot Tack Tester | Seller: Cell Instruments Co., Ltd | The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren... | |
SPC-01 Stretch Film Peeling Cling Tester | Seller: Cell Instruments Co., Ltd | The SPC-01 Stretch Film Peeling Cling Testermeasures the adhesion between two layers of stretch f... | |
FTT-01 Film Thickness Tester | Seller: Cell Instruments Co., Ltd | The FTT-01 FilmThickness Testerutilizes a mechanical scanning technique to measure the thickness ... |