Automatic Reaction Calorimeter/ Fully Automated Calorimetry System/ Fully Automated Calorimetry System
Product Features:
1. It offers three calorimetry methods: heat - flow, power - compensation, and reflux, allowing users to choose according to their needs.
2. It supports multiple operation modes such as isothermal, constant - temperature, and scanning.
3. Optional glass normal - pressure reaction vessels, glass medium - pressure reaction vessels, and metal high - pressure reaction vessels are available.
4. It has an external database, and one system supports the interchange of multiple sets of reaction vessels.
5. With high - power heating and cooling units, it features fast temperature - control response and high - precision exothermic measurement.
6. Automatic feeding control can be achieved by mass or volume measurement.
7. It can accurately measure and obtain process - safety - related data such as reaction heat - flow, reaction enthalpy, conversion rate, specific heat capacity of samples, adiabatic temperature rise, and the maximum temperature that an out - of - control system can reach.
8. The Chinese - language software platform enables flexible programming of experimental procedures, real - time monitoring of key reaction - process data, and online modification of experimental procedures and parameters.
9. It can display the temperature inside the vessel, the temperature of the jacket, the mass of the added materials, and other test status information in real - time.
10. The safety thresholds for key parameters and states can be set. In case of reaction out - of - control, it can be quickly cooled with one click, and it will issue alarms and automatically stop in case of abnormal states, effectively ensuring safety.
11. It can automatically generate and save charts and data, and export experimental analysis reports.
Technical parameters:
|
Calorimetry Method |
Heat Flow, Power Compensation (Option), Reflow (Option) |
|
Temperature Control |
|
|
Kettle Temperature Range |
(-25 to 200)°C |
|
Oil Bath Temperature Range |
(-45 to 250)°C |
|
Control Method |
Isothermal, Constant Temperature, Scanning |
|
Temperature Resolution |
1.0mK |
|
Temperature Control Precision |
±0.1K |
|
Silicone Oil Circulation Speed |
(35 to 76)L/min |
|
Control |
|
|
Driver Voltage Range |
(0 to 50)VDC |
|
Driver Maximum Current |
3.0A |
|
Heater Maximum Power |
120W |
|
Atmospheric Pressure Glass Kettle (Option) |
1000mL, other volumes available |
|
Reactor Volume |
Atmospheric Pressure |
|
Working Pressure |
Glass |
|
Reactor Material |
Medium-Pressure Glass Kettle (Option) |
|
Medium-Pressure Glass Kettle (Option) |
|
|
Reactor Volume |
0.6MPa or 1.2MPa |
|
Working Pressure |
Glass |
|
Kettle Material |
316L Stainless Steel or Hastelloy |
|
Kettle Lid Material |
1000mL, other volumes customizable |
|
High-Pressure Metal Reactor ( (Optional) |
10MPa |
|
Reactor volume |
316L Stainless Steel or Hastelloy |
|
Working pressure |
Stirrer |
|
Reactor material |
2000r/min, 3000r/min optional |
|
Stirrer |
|
|
Maximum speed |
Anchor or Paddle |
|
Maximum torque |
PTFE, 316L, or Hastelloy |
|
Stirrer paddle form |
Sampling system |
|
Stirrer paddle material |
Range 3100g, Accuracy 0.01g |
|
Sampling system |
|
|
Precision balance |
Medium-pressure pump: electromagnetic diaphragm pump, the maximum flow rate of 2L / h; high-pressure pump: precision piston pump, the maximum flow rate of 2.4L / h |
|
Sampling channel |
3*400V/50Hz(±10%)/20A |
|
Sampling pump |
7000VA |
|
Other parameters |
1200mm*600mm*1850mm |
|
Power supply |
600mm*700mm*1300mm |
|
Power |
210kg |
|
Test area size |
300kg |
|
Oil bath size |
Heat Flow, Power Compensation (Option), Reflow (Option) |
|
Oil bath weight |
Temperature Control |
|
Total machine weight |
(-25 to 200)°C |
Send product request
Other supplier products
| Anti Synthetic blood penetration tester | Standards: GB 19083-2010 Technical requirements of medical face masks - Anti-penetration property of 5.5 synthetic blood. YY/T 0691-2008 Clothin... | |
| Seat Belt Abrasion Tester | Standard: ISO 10555(Seat Belt Assemblies - Test Methods for Abrasion Resistance) ECE R16(Uniform Provisions Concerning the Approval of Safety Bel... | |
| DeMessia zigzag tester | Compliance Standards IEC 60695-2-1 (Fire hazard testing) ISO 6722 (Road vehicles - 60 V and 600 V single-core cables) ASTM D5422 (Standard Test ... | |
| Slip Resistance Tester | Standards 1. ASTM F2913standard test method for measuring the coefficient of friction for evaluation of slip performance of footwear and test sur... | |
| Resistance Tester for Protective Clothing/ANSI / ESD STM2.1 | Standards: GB/T 22042 - 2008 Clothing - Anti-static Performance - Test Method for Surface Resistivity GB/T 22043 - 2008 Clothing - Anti-static Per... |
Same products
| KL‑016A Benchtop High‑precision pH Meter | Seller: Kelilong Electron Co.Ltd | Product Description: Large‑screen display with high resolution and precision for con... | |
| Large Naïve VHH Library | Seller: AlpVHHs | Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o... | |
| pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester | Seller: Kelilong Electron Co.,Ltd | Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent... | |
| ORP-2026S Waterproof Soil ORP and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| TDS-2616 Waterproof EC/TDS/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Range EC ~19.9mS TDS Temp 0~50℃ R... |