Yellowing resistance test chamber
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The yellowing resistance test chamber, a key testing device in the field of materials science, accurately evaluates the color stability of materials during long-term use by simulating sunlight ultraviolet radiation and high-temperature environments. This equipment is widely used in industries such as plastics, rubber, textiles, coatings, and electronic products, providing a scientific basis for product quality control and material development.
Applications
Test method for determining the yellowing resistance of light and white products, such as upper and bottom materials for shoes, to approximate sunlight and ultraviolet light. According to the light-colored or white products, the phenomenon of yellow color is easy to occur in the natural sunlight for a long time, with the solar lamp and heating temperature control device to simulate the natural environment, within the specified time, observe the change of the surface color of the sample, determine the degree of discoloration of the sample, so as to determine the ability of the material to resist yellow under sunlight radiation.
Standards
HG/T3986:Plastic tower filler
ASTM D1748-24:Standard Test Method for Rust Protection by Metal Preservatives in the Humidity Cabinet
Features
This machine is designed to promote the metamorphism of vulcanized materials and then calculate the rate of change, stretching, and elongation. It also simulates the effects of ultraviolet radiation and heat from the sun. Samples are placed on the machine's table and subjected to UV radiation and temperature. Over time, the degree of yellowing and discoloration of the samples is observed, and the grayscale values can be used as a reference to determine the extent of yellowing. This is relevant to products that are exposed to radiation or sunlight during transportation.
The machine addresses the impact of color changes in the container environment on product quality. Using a 300W UV lamp, the experiment can be completed in a shorter time. This machine can be used as a basic yellowing resistance testing machine, an aging testing machine, and an oven, demonstrating its multi-functional capabilities. The machine is equipped with a forced hot air circulation control system to ensure uniform temperature distribution.
Technical Parameters
| Parameter | Specification |
|---|---|
| Light source | 300W UV light bulb imported from Germany |
| Temperature range | Room temperature +5℃ —— 200℃ |
| Temperature uniformity | ±2℃ |
| Electric heating power | 500W and 1000W two groups |
| Temperature control | LED digital display, PID temperature controller |
| Time control | 0——9999min or 0——9999h |
| Test frame | diameter 400mm, speed 1——20rpm adjustable, single-layer test frame |
| Working rate size | 500x500x600mm(WxDxH) |
| Dimensions | 500x500x600mm(WxDxH) |
| Power supply | AC220V, 1.8KW |
Accessoriess
Stainless steel test panel, high-temperature resistant observation window, single-layer test rack assembly, operating manual + certificate of conformity, power cord, fuse.
Test Procedures
1. Powering On and Preheating
Connect the test chamber to the power supply, turn on the main power switch, and wait for the system self-check to complete. After the self-check is successful, set the ultraviolet intensity, temperature, humidity, and other parameters according to the preset values, and start the equipment preheating program. The preheating time is generally 15-30 minutes. Samples can only be placed in the chamber after the temperature and humidity inside the chamber have reached a stable state.
2. Sample Placement and Test Start
Open the test chamber door, carefully place the prepared samples on the sample rack, ensuring that the samples do not obstruct the ultraviolet lamps and will not shake or move during equipment operation. Close the chamber door, confirm that the seal is good, and then click the "Start" button. The equipment will then officially enter the testing phase.
3. Process Monitoring and Recording
During the test, you can view real-time changes in temperature, humidity, ultraviolet intensity, and other data through the equipment control panel or accompanying software. It is recommended to record data every 1-2 hours. If abnormal parameter fluctuations are detected (such as a temperature deviation exceeding ±2℃ or a humidity deviation exceeding ±5%), the test must be immediately paused, the cause investigated and corrected before continuing. Regularly observe changes in the sample's appearance, such as yellowing or surface cracking, take photos for documentation, and record the details.
4. Test Completion and Sample Handling
When the preset test duration is reached, the equipment will automatically stop running. After the temperature inside the chamber drops to room temperature, open the chamber door and remove the samples. Place the samples in a standard laboratory environment (temperature 23±2℃, humidity 50±5%) for 2-4 hours to recover, then use a colorimeter, visual comparison, etc., to evaluate the yellowing resistance level and complete the test report.
Send product request
Other supplier products
| Aluminum Ointment Tube Toughness Tester | ASTM D2176 Folding Endurance Test Equipment | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The main purpose of the ductility tester for aluminum tubes is ... | |
| ASTM ISO Ring and Block Tribometer Supplier Factory | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Metal Ring-and-Block Friction and Wear Tester is a laboratory testing mac... | |
| High Pressure Gas Pulsation Test Machine for Pipeline and Seal Testing Supplier China | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features Designed for testing automotive motor parts, particularly turbochar... | |
| Material friction stick slip testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Stick-Slip Tribological Test Stand is a laboratory testing system used to evaluate fric... | |
| Rapid screening Calorimeter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: The rapid - screening calorimeter is a professional calorimetric ins... |
Same products
| Large Naïve VHH Library | Seller: AlpVHHs | Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o... | |
| pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester | Seller: Kelilong Electron Co.,Ltd | Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent... | |
| ORP-2026S Waterproof Soil ORP and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| TDS-2616 Waterproof EC/TDS/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Range EC ~19.9mS TDS Temp 0~50℃ R... | |
| EC-98330 CF ECOstick - Nutrient Tester | Seller: Kelilong Electron Co.,Ltd | Ideal for hydroponics and agriculture applications, theNutrient Tester accurately measures the el... |