Yellowing resistance test chamber

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The yellowing resistance test chamber, a key testing device in the field of materials science, accurately evaluates the color stability of materials during long-term use by simulating sunlight ultraviolet radiation and high-temperature environments. This equipment is widely used in industries such as plastics, rubber, textiles, coatings, and electronic products, providing a scientific basis for product quality control and material development.

Applications

Test method for determining the yellowing resistance of light and white products, such as upper and bottom materials for shoes, to approximate sunlight and ultraviolet light. According to the light-colored or white products, the phenomenon of yellow color is easy to occur in the natural sunlight for a long time, with the solar lamp and heating temperature control device to simulate the natural environment, within the specified time, observe the change of the surface color of the sample, determine the degree of discoloration of the sample, so as to determine the ability of the material to resist yellow under sunlight radiation.

Standards

HG/T3986:Plastic tower filler

ASTM D1748-24:Standard Test Method for Rust Protection by Metal Preservatives in the Humidity Cabinet

Features

This machine is designed to promote the metamorphism of vulcanized materials and then calculate the rate of change, stretching, and elongation. It also simulates the effects of ultraviolet radiation and heat from the sun. Samples are placed on the machine's table and subjected to UV radiation and temperature. Over time, the degree of yellowing and discoloration of the samples is observed, and the grayscale values can be used as a reference to determine the extent of yellowing. This is relevant to products that are exposed to radiation or sunlight during transportation.

The machine addresses the impact of color changes in the container environment on product quality. Using a 300W UV lamp, the experiment can be completed in a shorter time. This machine can be used as a basic yellowing resistance testing machine, an aging testing machine, and an oven, demonstrating its multi-functional capabilities. The machine is equipped with a forced hot air circulation control system to ensure uniform temperature distribution.

Technical Parameters

ParameterSpecification
Light source 300W UV light bulb imported from Germany
Temperature range Room temperature +5℃ —— 200℃
Temperature uniformity ±2℃
Electric heating power 500W and 1000W two groups
Temperature control LED digital display, PID temperature controller
Time control 0——9999min or 0——9999h
Test frame diameter 400mm, speed 1——20rpm adjustable, single-layer test frame
Working rate size 500x500x600mm(WxDxH)
Dimensions 500x500x600mm(WxDxH)
Power supply AC220V, 1.8KW

Accessoriess

Stainless steel test panel, high-temperature resistant observation window, single-layer test rack assembly, operating manual + certificate of conformity, power cord, fuse.

Test Procedures

1. Powering On and Preheating

Connect the test chamber to the power supply, turn on the main power switch, and wait for the system self-check to complete. After the self-check is successful, set the ultraviolet intensity, temperature, humidity, and other parameters according to the preset values, and start the equipment preheating program. The preheating time is generally 15-30 minutes. Samples can only be placed in the chamber after the temperature and humidity inside the chamber have reached a stable state.

2. Sample Placement and Test Start

Open the test chamber door, carefully place the prepared samples on the sample rack, ensuring that the samples do not obstruct the ultraviolet lamps and will not shake or move during equipment operation. Close the chamber door, confirm that the seal is good, and then click the "Start" button. The equipment will then officially enter the testing phase.

3. Process Monitoring and Recording

During the test, you can view real-time changes in temperature, humidity, ultraviolet intensity, and other data through the equipment control panel or accompanying software. It is recommended to record data every 1-2 hours. If abnormal parameter fluctuations are detected (such as a temperature deviation exceeding ±2℃ or a humidity deviation exceeding ±5%), the test must be immediately paused, the cause investigated and corrected before continuing. Regularly observe changes in the sample's appearance, such as yellowing or surface cracking, take photos for documentation, and record the details.

4. Test Completion and Sample Handling

When the preset test duration is reached, the equipment will automatically stop running. After the temperature inside the chamber drops to room temperature, open the chamber door and remove the samples. Place the samples in a standard laboratory environment (temperature 23±2℃, humidity 50±5%) for 2-4 hours to recover, then use a colorimeter, visual comparison, etc., to evaluate the yellowing resistance level and complete the test report.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Abrasive Wear Test Apparatus
Abrasive Wear Test Apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM G65 - 04 GB/T 3960-1983 Main Purposes The wet - type rubber wheel abrasiv...
Mask Bacterial Filtration Efficiency Tester
Mask Bacterial Filtration Efficiency Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Medical Masks bacterial filtration efficiency tester also called BFE test machine is to det...
SunTest color fastness tester manufacturer
SunTest color fastness tester manufacturer Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Qinsun si220 is a highly economic material color lightfastness tester that can...
Pump and Valve Test Equipment
Pump and Valve Test Equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) ISO 4406:2021 — Hydraulic fluid power — Fluids — Method fo...
High-Precision Rolling Contact Fatigue Testing Machine
High-Precision Rolling Contact Fatigue Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (GB/T 10622) Rolling Contact Fatigue Test Method for Metallic Materials (JB/T 1...
All supplier products

Same products

KL‑016A Benchtop High‑precision pH Meter
KL‑016A Benchtop High‑precision pH Meter Seller: Kelilong Electron Co.Ltd Product Description: Large‑screen display with high resolution and precision for con...
Large Naïve VHH Library
Large Naïve VHH Library Seller: AlpVHHs Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o...
pH-2398  pH/EC/ORP/Temperature  multi-parameter Water Quality Tester
pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester Seller: Kelilong Electron Co.,Ltd Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent...
ORP-2026S  Waterproof Soil ORP and Temperature Meter
ORP-2026S Waterproof Soil ORP and Temperature Meter Seller: Kelilong Electron Co.,Ltd 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV...
TDS-2616  Waterproof EC/TDS/Temperature Meter
TDS-2616 Waterproof EC/TDS/Temperature Meter Seller: Kelilong Electron Co.,Ltd Range EC ~19.9mS TDS Temp 0~50℃ R...