Nasal Oxygen Cannula Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
This device is used to test various performance characteristics of nasal cannulas, such as airflow resistance and resistance to kinking. It is also known as a nasal cannula airflow resistance and kinking resistance tester or nasal cannula testing equipment. This device is suitable for all nasal cannulas, whether they are standalone or used in conjunction with humidifiers or masks. It can test parameters such as airflow resistance, resistance to kinking, leakage, pressure resistance, and bending resistance (patency).
Applications
The nasal oxygen tube tester is mainly used to test key parameters of nasal oxygen tubes, such as oxygen content, flow rate, and pressure, as well as to evaluate their physical properties like pressure - resistance, crush - resistance, and air permeability. This tester plays an important role in various aspects, including the production, quality control, and pre - use inspection of nasal oxygen tubes, ensuring that nasal oxygen tubes can provide patients with a stable and effective oxygen supply. Specifically, its main uses are as follows:
- Production Quality Control: During the production of nasal oxygen tubes, manufacturers can use this tester to conduct sampling inspections on finished products, ensuring that each batch of nasal oxygen tubes complies with relevant standards and regulations. - Pre - use Inspection: Before using nasal oxygen tubes, medical institutions can use this tester to conduct quality inspections to ensure that the performance of nasal oxygen tubes is stable, safe, and reliable. - Research, Development and Improvement: The nasal oxygen tube tester can also be used in the research, development and improvement process of nasal oxygen tubes, helping R & D personnel understand the performance characteristics and deficiencies of nasal oxygen tubes, so as to make targeted improvements and optimizations.
Standards
YY/T 1543 - 2017:Nasal Oxygen Cannula
GB/T 1962.1-2005:Conical fittings with a 6%(Luer) taper for syringes, needles and certain other medical equipment -- Part 1: General requirement
Features
• Supports five major testing functions: airflow resistance, crush resistance, leak testing, and pressure resistance.
• 7-inch color touchscreen control with an intuitive interface for a significantly improved user experience.
• The device is equipped with a miniature printer for real-time printing of test results.
• Equipped with a high-precision pressure sensor, allowing for stable control of output pressure via a rotating pressure knob.
• Equipped with a high-precision flow meter for accurate measurement of flow through the tubing.
• Unique rotary design accommodates crush resistance testing of nasal oxygen tubes with various inner diameters.
• Features a universally designed conical test interface, meeting the testing requirements of most products on the market.
• The device has powerful built-in data storage capabilities.
• Miniature printer and universal USB data interface for convenient data output and transfer.
• Intelligent features such as overload protection and power-off memory effectively ensure user safety.
• Free software upgrade service is provided.
Technical Parameters
| Parameter | Specification |
|---|---|
| Test Pressure Range | Usually covers 0 - 600kPa or higher, to meet testing requirements of nasal oxygen tubes with different specifications and materials |
| Test Flow Range | Simulates normal oxygen supply flow (e.g., not less than 15L/min), ensuring air permeability of nasal oxygen tubes in actual use |
| Accuracy | High level of accuracy; e.g., pressure accuracy reaches ±1% or higher, ensuring test result accuracy and reliability |
| Data Collection and Display | Equipped with data collection card and display screen, which collect and display real-time test data (pressure, flow rate, time, etc.) for easy observation and recording |
| Clamping Device | Fixes nasal oxygen tubes to keep their position stable (no displacement/shaking during testing); adaptable to nasal oxygen tubes of different specifications and shapes |
| Operation Interface | Simple and clear for easy operation; some testers are equipped with touch-screen control and menu-style functions to improve operational convenience |
Accessoriess
1 main unit;
1 set of testing software;
1 instruction manual;
1 certificate of conformity;
1 warranty card;
1 delivery receipt;
1 nameplate;
1 power cord;
1 set of wrenches;
Several brochures;
1 x 1/8 barbed connector;
1 x 1/8 Luer connector (male).
Test Procedures
1. Pre-test Preparation
Check that the instrument's power supply and pipeline connections are normal, start the instrument and preheat it to a stable working state.
Calibrate the pressure and flow sensors (refer to the instrument calibration guide) to ensure that the detection accuracy meets the requirements.
Clean the fixtures and pipelines of impurities, prepare the nasal oxygen cannula samples to be tested, and record the basic information of the samples, such as specifications and materials.
2. Sample Installation
Connect the nasal oxygen cannula sample to the corresponding pipeline interface of the instrument, and use a special fixture to fix both ends of the sample, ensuring that the connection is sealed without leakage and that the sample is not bent or displaced.
3. Test Parameter Setting
Through the instrument's touch screen interface, select the target test item (such as airflow resistance, pressure resistance, leakage test, anti-flattening performance, etc.).
According to the corresponding standard for nasal oxygen cannulas (such as YY/T 1543-2017), set the corresponding test parameters (such as test flow rate, pressure threshold, pressure holding time, etc.), and save the parameters after confirmation.
4. Starting the Test
After confirming that the sample connection and parameter settings are correct, click the "Start" button. The instrument will automatically execute the test process, collecting and displaying data such as flow rate, pressure, and time in real time.
5. Test Process Monitoring
During the test, observe the data changes on the instrument interface and the sample status. If any abnormalities such as loose pipelines or leaks occur, pause the test immediately and handle the issue.
6. Test Completion and Cleanup
After the test is completed, the instrument will automatically shut down. Record or export the test data (such as airflow resistance value, pressure resistance results, etc.).
Loosen the fixture and remove the sample, clean the fixture and pipelines, turn off the instrument power, and prepare the test report.
Send product request
Other supplier products
| SUGA GX75 7.5kW Xenon Weather Meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications SUGA GX75 7.5kW Xenon Weather Meter is designed to artificially reproduce ind... | |
| HVAC air filter test system ISO 16890 compliant | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Filter Test System has been developed especially for air filter testing a... | |
| Melt Index Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards: ISO 1133. ASTM D1238. GB/T 3682. JIS K7210 Main uses: The melt flow rate mete... | |
| Industrial oil separator test system factory direct | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Oil Separator Test Rigis designed for automated testing procedures in ord... | |
| Luggage Walked Wear Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction This product is used for suitcases, bags, strollers with wheels&helli... |
Same products
| pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester | Seller: Kelilong Electron Co.,Ltd | Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent... | |
| ORP-2026S Waterproof Soil ORP and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| TDS-2616 Waterproof EC/TDS/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Range EC ~19.9mS TDS Temp 0~50℃ R... | |
| EC-98330 CF ECOstick - Nutrient Tester | Seller: Kelilong Electron Co.,Ltd | Ideal for hydroponics and agriculture applications, theNutrient Tester accurately measures the el... | |
| PH-808 Waterproof Soil PH Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-808 Range PH ~14.00PH Temp 0~50℃ ... |