.

Direcct flame impingement Tester with BS 476-12,Surface spread of flame test

Introduction:

The testeris designedaccording to the BS476-12:1991.Method of test for ignitability of products by direct flame impingement.The accuracy of the tester meets the requirements of relevant standards and meets the control requirements for the accuracy of measurement.

Model: STD-BS 476-12

Standards:

1.Voltage:220V + 10%, 50Hz;

2.Burner.

(1)Ignition source D. A gas burner comprisinga 185 mm long horizontal stainless steeltube(12.0 mm outside diameter, 9.0 mm insidediameter) closed at each end and fitted with acentral gas supply pipe. The burner tube shall havea row of 14 holes of 1.5 mm diameter at 12.5 mmcentres arranged so that the gas jets issue at anangle of 45 below the horizontal.

Theflowmeter shall be calibrated to supply a propanegas flow rate at 25C of 2 l/min

NOTE Under these conditions the flame height isapproximately 240 mm.

(2)Ignition source E. a gas burner comprisinga 185 mm long horizontal stainless steeltube(12.0 mm outside diameter, 9.0 mm insidediameter)closed at each end and fitted with acentral gas supply pipe. The burner tube shall havea row of 14 holes of 1. 5 mm diameter at 12.5 mmcentres arranged so that the gas jets issue at anangle of 45 below the horizontal.

3.Aburner carriage consisting of a movablecolumn which incorporates a 10 mm On x 1 mmwall stainless steel tube terminated by athreaded boss to which the various burners canbe fixed.

4.A length of 5 mm internal diameter hose not greater than 3.0 m in length to connect the flowmeters to the burner carriage via a gas cock mounted on the carriage.

5.Test frame. A horizontal steel platform to whicha sliding burner carriage and burner tube areattached. At one end of the platform, means shall beprovided to maintain the specimen holder in avertical position.

6.Specimen holder. The vertical specimen holdershall be capable of accommodating the largest size ofspecimen Specimens shall be gripped at intervalsalong both vertical edges.

For narrower specimens, holders may be designed tofit within the widest holder in order to provide acommon position for testing.

7.Burner carriage and tube. The ignition source shall be mounted on a burner support tube fitted to the burner carriage(see Figure 1). The tube shall be equipped with means to allow vertical adjustment of the ignition source position as required by the various tests. The burner carriage shall be designed in such a way that the distance between the burner and the specimen is obtained accurately. reproducibly and automatically and manufactured so that the ignition source can be brought into the prescribed position smoothly and within 1s.

8.A clamp used to fix the soft wood。

9.Draught shields. Draught shields of 9 mm thicknon-combustible board, triangular in shape, with abase of approximately 500 mm andapproximately 750 mm in height shall be providedfor use with ignition sources A. B and C.

Parameters:

1.Propane flow:10-1000±5 mL / min,

2.Air flow:0-100L/min

3.Burning angle:45and90º;

4.Various test parameters can be set directly on touch screen.。

5.Control: touch screen +PLC control

6.Test time: 1-99minsarbitraryset.

Gas and air system:

1.Gas (customerprepared)

(1)Propane and LPG。

(2)Air supply pipe, compression release valve, safety valve.

2.Air source system (customerprepared)

(1)Compressed air: 0-6kgf

(2)Switch valve and pressure gauge


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Single - Strand Bending Tester
Single - Strand Bending Tester Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to easily measure and quantify softness, elasticity, ...
Leakage Test System,ISO 20485 sealed component leak tester
Leakage Test System,ISO 20485 sealed component leak tester Test System for testing tightness and leackage for a high diversity of components and devices. With Leak Test Systems of series it is possible to t...
Textile Fiber Composition Analyzer
Textile Fiber Composition Analyzer Standard ASTM D276(Standard Test Method for Identification of Fibers in Textiles) ISO 1833(Determination of Fiber Content in Textiles) AATCC 2...
Automotive HVAC Manikin
Automotive HVAC Manikin Application This system is widely used for: Vehicle heating, ventilation, and air conditioning (HVAC) system design and validation Passenger com...
Total Knee Joint Prostheses Wear Tester
Total Knee Joint Prostheses Wear Tester Standard ISO 14243-1:2014: Specifies wear testing parameters for total knee prostheses, including axial loading, flexion/extension kinematics, and...
All supplier products

Same products

Full-Body Garment Stress Tester,FZ/T 70015
Full-Body Garment Stress Tester,FZ/T 70015 Seller: Standard International Group (HK) Limited TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe...
Industrial Dry Cleaning Machine,industrial garment steamer
Industrial Dry Cleaning Machine,industrial garment steamer Seller: Standard International Group (HK) Limited TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel...
MST Medical Compression Stocking Tester,compression sock tester
MST Medical Compression Stocking Tester,compression sock tester Seller: Standard International Group (HK) Limited The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the...
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool Seller: Standard International Group (HK) Limited Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi...
Dental material color stability tester
Dental material color stability tester Seller: Standard International Group (HK) Limited Application The applications of color stability testers for dental materials are mainly reflecte...