Safety Mat Safety Relay
Safety mat relaymodules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function controllers safety relay offer 2 or 4-wire safety mats/edges. Automatic reset and monitored manual reset are available.
The programmable safety relays support 3 safety output contacts (N/O) and 1 auxiliary output contacts (N/C) or 2NO+1NC+1SO or 2NO(t)+1NC(t).
Features & Advantages of Safety Mat Safety Relay
2-wire safety mats/edge
4-wire safety mats/edge
Automatic reset
Monitored manual reset
Parameter of Safety Mat Safety Relay
CZSR8301-3A1B |
CZSR8301-3A1B(M) |
CZSR8302-3A1B |
CZSR8303-3A1B |
|
Supply voltage |
24V DC/AC |
24V DC/AC |
24V DC/AC |
100V~230V AC |
Voltage tolerance |
- |
|||
Current consumption |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤7 VA (220V AC) |
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤10mA (24V DC) |
≤10mA (220V AC) |
Cable resistance |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
Input devices |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats, safety edges (2 or 4-wire) |
Number of contacts |
3NO+1NC |
3NO+1NC |
3NO+1NC |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
External contact fuse protection |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
≥107 |
≥107 |
Utilisation category |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤150ms |
≤300ms |
≤300ms |
Delay-on de-energisation |
≤30ms |
≤30ms |
≤30ms |
≤30ms |
Recovery time |
≤300ms |
≤300ms |
≤100ms |
≤500ms |
Supply short interruption |
20ms |
20ms |
20ms |
20ms |
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
Vibration |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
Relative humidity |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
Elevation |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
Overvoltage category |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅲ |
Pollution degree |
2 |
2 |
2 |
2 |
Rated insulation voltage |
250V AC |
250V AC |
250V AC |
250V AC |
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
Safety integrity level |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
Performance level |
PLe |
PLe |
PLe |
PLe |
Category |
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
External contact fuse protection |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
Utilisation category |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
|
Semiconductor output data |
Number of semi-output:1SO |
Number of semi-output:1SO |
Driving ability:20mA/24V DC |
Driving ability:20mA/24V DC |
|
Switch-on delay |
≤300ms |
≤300ms |
Delay-on de-energisation |
≤30ms(instantaneous) |
≤30ms (instantaneous) |
0s, 0.5s, 1s, 2s, 3s, 5s(Deleted factory set as 5s) |
||
Recovery time |
≤100ms |
≤100ms |
Supply short interruption |
20ms |
20ms |
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
Vibration |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
Relative humidity |
10%~90% |
10%~90% |
Elevation |
≤2000m |
≤2000m |
Overvoltage category |
Ⅲ |
Ⅲ |
Pollution degree |
2 |
2 |
Rated insulation voltage |
250V AC |
250V AC |
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
Safety integrity level |
SIL3 |
SIL3 |
Performance level |
PLe |
PLe |
Category |
SHANGHAI CHENZHUINSTRUMENT CO., LTD. is a very established provider that specialises in automation safety.
We have over 24 years of experience in the design and manufacture of intrinsic barrier, surge protection device, isolated signal conditioner, safety relay, low power transmitter and temperature transmitter. Our products and solutions cover many areas--from process automation safety to factory automation.
Send product request
Other supplier products
AC Power SPD | AC SPD The power surge protector for ac compressoris designed to prevent transient surge conditions. Large single surge events, such as lightning,... | |
Conceptual Difference Between Temperature Transmitter and Temperature Sensor | differential temperature transmitterand temperature sensor The temperature sensor is a general term for devices that can sense a prescribed me... | |
Safety Relay | Automation direct safety relayare mainly applied to the safety control circuit, connecting the safety sensing elements and mechanical equipment mot... | |
Photovoltaic 1000 DC Power SPD | PhotovoltaicSPDfor DC power, 1000VDC; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features & Advantages of Ph... | |
Power Transmitter | Power transmittercan transfer complicated current like 0~1A/0~5A/0~10A into industry-standard output, adopting the true RMS detection technology. W... |