Safety Mat Safety Relay
Safety mat relaymodules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi-function controllers safety relay offer 2 or 4-wire safety mats/edges. Automatic reset and monitored manual reset are available.
The programmable safety relays support 3 safety output contacts (N/O) and 1 auxiliary output contacts (N/C) or 2NO+1NC+1SO or 2NO(t)+1NC(t).
Features & Advantages of Safety Mat Safety Relay
2-wire safety mats/edge
4-wire safety mats/edge
Automatic reset
Monitored manual reset
Parameter of Safety Mat Safety Relay
CZSR8301-3A1B |
CZSR8301-3A1B(M) |
CZSR8302-3A1B |
CZSR8303-3A1B |
|
Supply voltage |
24V DC/AC |
24V DC/AC |
24V DC/AC |
100V~230V AC |
Voltage tolerance |
- |
|||
Current consumption |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤7 VA (220V AC) |
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤10mA (24V DC) |
≤10mA (220V AC) |
Cable resistance |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
Input devices |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats (4-wire) |
Safety mats, safety edges (2 or 4-wire) |
Number of contacts |
3NO+1NC |
3NO+1NC |
3NO+1NC |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
External contact fuse protection |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
≥107 |
≥107 |
Utilisation category |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤150ms |
≤300ms |
≤300ms |
Delay-on de-energisation |
≤30ms |
≤30ms |
≤30ms |
≤30ms |
Recovery time |
≤300ms |
≤300ms |
≤100ms |
≤500ms |
Supply short interruption |
20ms |
20ms |
20ms |
20ms |
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
Vibration |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
Relative humidity |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
Elevation |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
Overvoltage category |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅲ |
Pollution degree |
2 |
2 |
2 |
2 |
Rated insulation voltage |
250V AC |
250V AC |
250V AC |
250V AC |
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
Safety integrity level |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
Performance level |
PLe |
PLe |
PLe |
PLe |
Category |
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
External contact fuse protection |
10A gL/gG NEOZED (NO); |
10A gL/gG NEOZED (NO); |
6A gL/gG NEOZED (NC) |
6A gL/gG NEOZED (NC) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
Utilisation category |
In accordance with EN60947-5-1: |
In accordance with EN60947-5-1: |
AC-15, 5A/230V; DC-13, 5A/24V |
AC-15, 5A/230V; DC-13, 5A/24V |
|
Semiconductor output data |
Number of semi-output:1SO |
Number of semi-output:1SO |
Driving ability:20mA/24V DC |
Driving ability:20mA/24V DC |
|
Switch-on delay |
≤300ms |
≤300ms |
Delay-on de-energisation |
≤30ms(instantaneous) |
≤30ms (instantaneous) |
0s, 0.5s, 1s, 2s, 3s, 5s(Deleted factory set as 5s) |
||
Recovery time |
≤100ms |
≤100ms |
Supply short interruption |
20ms |
20ms |
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
Vibration |
Vibration frequency: 10Hz~55Hz; |
Vibration frequency: 10Hz~55Hz; |
Vibration amplitude: 0.35mm |
Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
Relative humidity |
10%~90% |
10%~90% |
Elevation |
≤2000m |
≤2000m |
Overvoltage category |
Ⅲ |
Ⅲ |
Pollution degree |
2 |
2 |
Rated insulation voltage |
250V AC |
250V AC |
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
Safety integrity level |
SIL3 |
SIL3 |
Performance level |
PLe |
PLe |
Category |
SHANGHAI CHENZHUINSTRUMENT CO., LTD. is a very established provider that specialises in automation safety.
We have over 24 years of experience in the design and manufacture of intrinsic barrier, surge protection device, isolated signal conditioner, safety relay, low power transmitter and temperature transmitter. Our products and solutions cover many areas--from process automation safety to factory automation.
在线联系供应商
Other supplier products
GS8500-EX Digital Intrinsic Safety Barrier | Digital input, relay output isolated barrier, transfers digital signals (dry contact or NAMUR proximity switch) from hazardous area to safe area. E... | |
Safety Mat Safety Relay | Safety Mat Relay Safety relay modules provide a high level of fail-safe operation for critical processes and protection. This safety mat and multi... | |
DO Signal (SIS) Input 24V DC 5A Safety Relay | These safety relay are suitable for the application of E-Stop button, safety gate and DO signal from SIS, with several contacts output. The emer... | |
Safety Relay | Safety Relay Automation direct safety monitering relays are mainly applied to the safety control circuit, connecting the safety sensing elements a... | |
Signal SPD | Electronic devices are always threatened by power surges and transients caused by power failures or nearby lightning strikes. Signal SPDsurge pr... |
Same products
Wholesale Full Automatic Adult Diapers Making Machines for Light Incontinence Pads Supplier | 卖方: 泉州市沃盟智能设备有限公司 | Short Description: Product Name: Automatic Adult Diapers Making Machines for Light ... | |
China High-Quality Adult Diaper Machine Manufacturers | 卖方: 泉州市沃盟智能设备有限公司 | Short Description: Customization: Available After-sales Service: ... | |
China's Best Adult Diaper Machine for Sale | 卖方: 泉州市沃盟智能设备有限公司 | Short Description: Customization: Available After-sales Service: ... | |
China High-Quality Adult Diaper Machine Factories | 卖方: 泉州市沃盟智能设备有限公司 | Short Description: Customization: Available After-sales Service: ... | |
Disposable Anti-Leak Rapid-Dry Period Pants | Comfortable Overnight Underwear | 卖方: Hangzhou Shujie Hygiene Products Co.,Ltd. | Size: M 2PCS/bag Waist:≥95cm L 2PCS/bag Waist:≥105cm 100% Breathable Fl... |