.

High Precision Spectroradiometer Sphere LED Testing Equipment

High Precision Spectroradiometer Sphere LED Testing Equipment LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED's quality should be tested by checking its photometric,Website:, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-8000 or LMS-9000) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.System Configuration: ‍‍High Precision CCD Spectroradiometer‍‍ (LMS-8000 or LMS-9000), ‍‍Optical Fiber‍‍ (CFO-1.5M),‍‍Digital Power Meter ‍‍(LS2012 or LS2010), ‍‍DC Power Source‍‍ (DC Series), ‍‍AC Power Source‍‍(LSP-500VAR or LSP-1KVAR), ‍‍Integrating Sphere‍‍ (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), ‍‍Optical Path Converter‍‍ (LS512B), 19 Inch Cabinet (CASE-19IN)Measures:  • Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, Spectrum Test  • Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux  • Electrical: Voltage, Current, Power, Power Factor (Option: VF, IF, VR, IR)  • LED optical maintenance test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.  Specification:  • Spectral Range Wavelength: 380nm~800nm (LMS-8000 Option: 380nm~1050nm or 200nm~800nm).  • Spectral Wavelength Accuracy: ±0.5nm, Wavelength Reproducibility: ±0.2nm  • Sample Scanning Steps: ±0.1nm  • Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.003  • Correlated Color Temperature CCT: 1,000K~100,000K, CCT Accuracy: ±0.3%  • Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)  • Photometric linear: ±0.5%  • Stray light:<0.015%(600nm) and <0.03%(435nm) • The system includes the auxiliary lamp device and the software includes self-absorption function  • The system can test the inside and outside integrating sphere temperature  • Connect with PC via USB, English version software can be run under WinXP, Win7 and Win8  • The LM-79 Photometric, Color and Electricity report can be exported PDF and LM-80 LED Optical Maintenance test report can be exported Excel or PDF0.03%(435nm)

Send product request

To: Lisun Electronics (Shanghai) Co., Ltd
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Lamp Start, Run-up Time And LED Flicker Test
Lamp Start, Run-up Time And LED Flicker Test Lamp Start,Website:, Run-up time and LED Flicker Test Dated 14th December, 2012, the EU officially released the (EU) NO 1194/2012rules.Compared wit...
EN55015 EN55022 9kHz~300MHz EMI Receiver System
EN55015 EN55022 9kHz~300MHz EMI Receiver System EN55015 EN55022 9kHz~300MHz EMI Receiver System KH3962 is an automatic EMI receiver system. It is a main test system for EMI (Electro Magnetic Inte...
LM-79 Moving Detector Type C Goniophotometer
LM-79 Moving Detector Type C Goniophotometer LM-79 Moving Detector Type C Goniophotometer LSG-1900 Moving Detector Type C Goniophotometer completely meets LM-79 Clause 9.3.1 requirement. The L...
Compact Near Field Goniophotometer For IES LDT File Test
Compact Near Field Goniophotometer For IES LDT File Test Compact Near Field Goniophotometer For IES LDT File Test The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distrib...
IEC 60529, IEC 60598, IEC 60335 And IEC 60034-5 Water Ingress Testing Equipment For IPX1 To IPX8
IEC 60529, IEC 60598, IEC 60335 And IEC 60034-5 Water Ingress Testing Equipment For IPX1 To IPX8 IEC 60529,Website:, IEC 60598, IEC 60335 and IEC 60034-5 Water Ingress Testing Equipment for IPX1 to IPX8 JL-X Water Ingress Testing Equipment is a...
All supplier products

Same products

OEM Metal Components for Water Tank Systems
OEM Metal Components for Water Tank Systems Seller: Yongjia County Yaokang Technology Co., Ltd. Stainless Steel Float Ball is designed for mechanical liquid level control systems, water tanks, ...
Plasma Indicator Strips Tape
Plasma Indicator Strips Tape Seller: Hopeway AMD Plasma Indicator Strips Tape provides a convenient solution for monitoring plasma sterilization p...
Custom Stainless Components for OEM Applications
Custom Stainless Components for OEM Applications Seller: Yongjia County Yaokang Technology Co., Ltd. Our stainless steel float balls are designed for float valves, water tanks, and industrial liquid...
Precision Design for Automatic Liquid Level Control
Precision Design for Automatic Liquid Level Control Seller: Yongjia County Yaokang Technology Co., Ltd. Our stainless steel float balls are designed for liquid level control applications in valves, tan...
China manufacturer power supply VM-5H3 for power generation
"China manufacturer power supply VM-5H3 for power generation Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China manufacturer power supply VM-5H3 for power generation Is to use the generator sets of prof...