Venturi tube
Venturi tube
Product name:venturi tube
Product code:16311-252
Update time:2015.08.25
Views:913
Processing custom origin:in kaifeng
Venturi tube models:the throttle device
Type:venturi tube
Measuring range:50-1000 - mm
Nominal size:50-1000 - mm
Accuracy:+ 0.1% to + 1.5%
Pressure of work:4.0 (Mpa)
Scope of application:gas, liquid
throttling device, also known as differential pressure flowmeter, Orifice flowmeter contains (integrated orifice flow meter, standard orifice, annular orifice flow meter, integrated annular orifice flow meter)
Venturi tube can be divided according to function name gas flow meter, flue gas meter, steam flow meter, gas flow meter, compressed air flow meter, liquid flow meter.
Classic venturi tube is also called the classical venturi tube, used to call standard venturi tube. IS05167 or GB/T2624 standard. Used to measure stable single-phase fluid flow in a closed pipe, often used to measure air, gas, gas, water and other fluid flow. Venturi tube (Venturi throat) according to the structure is divided into working "Venturi tube and plug-in Venturi tube. Hot blast stove combustion wind in a steel plant, the cold wind, gas metering (blast furnace gas, coke oven gas, converter gas) and thermal power plant boiler primary air and secondary air big diameter pipe, low velocity meter measurement has received the good effect. To solve the existing industrial enterprises in the low pressure, large diameter, all kinds of low velocity gas flow precise measurement. Wide measuring range, easy installation of flow measuring devices. Unique structure design and data processing method is strictly on the basis of fluid mechanics, and in the national large-scale key wind tunnel laboratory compaction flow calibration.
USES: can be widely used in the oil, chemical industry, metallurgy, electric power and big diameter control and measurement of the fluid.
Features:
1, simple structure, durable, stable performance.
2, small pressure loss, the energy saving fluid conveying.
3, 50-1200 range in size, don't need real flow calibration. Beyond this range, you can reference. When requiring high precision, real flow calibration can be performed.
4, installation size of ontology is longer, the large diameter instrument, not easy to transport installation.
The main technical parameters:
Nominal diameter (mm) : (to 48 ") (2600)
Nominal pressure (MPa) : 0.25 4.0 (6.3)
Precision (uncertainty) : + 0.1% to + 1.5%
(1) on the fluid resistance small, about 150 pa so low energy consumption.
(2) the pressure difference is big, high precision, wide measurement range.
(3) stability is good, have a smooth differential features.
(4) the use of a wide range, general gas, flue gas, blast furnace gas containing impurities more, use for a long time without blocking phenomenon.
(5) convenient installation, easy to maintain for a long time.
(6) before and after the straight pipe, shorter than standard throttle device, 1 D after about 1.5 D.
(7) with temperature and pressure from online correction integration structure.
Double venturi tubeof speed is a kind of used for power plants of large diameter gas pipeline flow measurement, measurement of large diameter pipeline flow velocity differential pressure sensitive, cooperate with the differential pressure transmitter, record and display instrument tube can be obtained by measuring point of the instantaneous velocity value. By adjusting the instrument can also be adjusted in pipe flow, its characteristics are as follows: compared with the throttling device: small volume. Permanent minimal pressure loss. Simple structure, it is convenient for inspection, cleaning and maintenance of all.
Parameter is introduced:
(1) the applicable industrial pipeline: circular cross section pipe nominal diameter:
DN = 500 ~ 4000 mm rectangle pipe: W * H = 600 * 600 ~ 3600 x 3600 mm and the width and height of the rectangular pipe.
(2) the nominal pressure: PN acuities were 6.4 MPa
(3) working temperature lower than 400 ℃ (higher than 400 ℃, the order should be specified)
(4) the differential values: 0 ~ 1.0, 1.6, 2.5, 4, 6.3, 10,16,25 and 40 kpa
(5) repeatability error: + 0.1% to + 1.5%
(6) stability: plus or minus 10 pa
(7) level of accuracy: 0.5 on the Richter scale, level 1, 1.5 on the Richter scale, level 2
(8) sensor over size: welded steel pipe G3/4 ", M20 x 1.5 or 1/2 NPT
(9) measured medium, metallurgy, blast furnace gas, the cold wind, combustion-supporting air, gas, mixed gas, flue gas, recycle
Power: a wind, secondary air, coal and wind, etc
Chemical industry: corrosive gas, air and other media
Send product request
Other supplier products
| magnetic float level gauge plant | Magnetic level gauge magnetic float level gauge plant top mounted magnetic float level gauge Product name:standard cavity magnetic flap liquid l... | |
| Magnetic level gauge | Magnetic level gauge Product name:standard cavity magnetic flap liquid level gauge Product code:141549-111 Update time:2015.08.26 Views:155 Pr... | |
| Double cavity magnetic flap liquid level gauge | Double cavity magnetic flap liquid level gauge Product name:double cavity magnetic flap liquid level gauge Product code:155757-647 Views:575 Pr... | |
| magnetic float level gauge | Stainless steel magnetic float liquidometer magnetic float level gauge magnetic float level gauge plant Product name:Stainless steel magnetic fl... | |
| high temperature and high pressure type magnetic flap liquid level gauge | Top mounted magnetic float liquidometer high temperature and high pressure type magnetic flap liquid level gauge Product name:high temperature an... |
Same products
| WYLIE WL-155 SIM Card Tester for iPhone 14-17 Pro Max & Android | Seller: China PHONEFIX Technology Co., Ltd | WYLIE WL-155 SIM Card Tester is used to detect SIM card circuits and supports dual-SIM detection ... | |
| HCV1500 High-precision Voltage Sensor | Seller: Shenzhen Hangzhi Precision Electronics Co., Ltd | HCV1500 high-precision voltage sensor is a voltage sensor that can measure DC, AC, pulse and vari... | |
| Xenon Test Chamber | Seller: Standard International Group (HK) Limited | Features and Benefits 1.The use of xenon arc lamp as a light source, can simulate the full sunli... | |
| Single Cable Vertical Flame Tester | Seller: Qinsun Instruments Co., LTD | Introduction Single Cable Vertical Flame Tester is used for the vertical flame propagation of a ... | |
| Safety Helmet Flammability Tester | Seller: Qinsun Instruments Co., LTD | Product Introduction: Safety hat flame retardant performance tester for safety hat flame retarda... |