Friction Charging Tester
Standards compliant:
JIS L-1094;
JIS T-8118;
ZB W 04008-89;
GB / T12703.2-2009;
GB 12014-2009;
GB / T23316-2009
Calculation formula:
Q = CV / A
Here, C: the charge amount of the capacitor (F) = 0.1 × 10-6 (F)
V: Voltage reading of potentiometer (V)
A: friction area of sample (m2) = 0.25 × 0.25 (m2)
Steps:
1, connecting the Faraday tube and the amount of charge measurement device: the end of a dedicated cable connected with the input of the charge meter connected to the other end of the Faraday tube with the outer cylinder of the socket connection.
2, turn on the charge amount of the tester power - the power switch up to the "1" position.
3, press the "clear" button, so that the charge meter shows the number is zero.
4, with a roller friction machine friction test, immediately after the end of the friction with the insulation rods into the Faraday tube tube inside the tube. In this process the specimen and other objects should be kept above 300mm.
5. Read the reading on the charge quantity measuring device.
Friction Charging TesterNote:
- 1, the system of Faraday tube outer cylinder should be reliably grounded.
- 2. Clear the charge amount measurement unit before each measurement.
- 3, the measured object must be measured from the power supply.
- 4, before the test, please turn on the power switch to make the machine warm up for 15 minutes.
- 5, voltage / current generator is not to sell goods.
- Fabric Friction Charging Charge Tester:
Voltage meter (R8240): 1 set
Capacitor: 1 set
Cable (A01009-200): 1 root
Connection cable (A01009-50): 1 root
Power supply-type strip in addition to the electrode: 1 root
Friction abutment / ground pad (nylon friction cloth): 1 set
Insulated rods (20Φ x 500L mm acrylic clear fiber): 1 root
Certificate of proof of voltage meter (traceability): 1 book
Send product request
Other supplier products
| Overall Protective Performance Tester | The overall protective performance tester is designed with new technology, mainly used for determining the protection performance of fire protectio... | |
| Catheter Flow Meter | Standards GB/T 15812.1 - 2005 Non - Vascular Intravascular Catheters - Part 1: General Performance Test Methods YY 0285.1 - 2017 Disposable Steri... | |
| Cone Calorimeter | Ignition system 1、 10kV spark lighter with safe fire-off device. The lighter automatically detect its position via the lever which connects to the... | |
| Catheter Flexibility Tester | Main Uses The catheter flexibility tester is mainly used to evaluate the flexibility and durability of catheters or guidewires during bending or t... | |
| Solid electrolyte analysis system | Standard ISO 9001:2015 (Quality Management System) ASTM E1970-21 (Standard Guide for Electrochemical Impedance Spectroscopy) IEC 62660-2 (Secondary... |
Same products
| Optical Brightener OB-1 (OBA 393) | Seller: Jinan Ogilvy Chemical Co., Ltd | Chemical Name: 2-[(Ethylsulfanyl)methyl]phenyl methylcarbamateC.I.: 393CAS: 1533-45-5Molucular Fo... | |
| PH-A63 Waterproof PH/EC/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A63 Range PH ~14.00PH EC 0~19.99mS/c... | |
| PH-A6 Waterproof pH and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A6 Range PH ~14.00PH Temp 0~50℃ ... | |
| PH-A8 Waterproof Soil PH Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A8 Range PH ~14.00PH Temp 0~50℃ ... | |
| TH021WIFI Internet of Things TEMP&HUMIDITY Controller | Seller: Kelilong Electron Co.,Ltd | Product description: The electronic thermostat can be used for a variety oftemperature control... |