Prefilled Syringe Plunger Force Tester

The Push - force Tester for Prefilled Syringes is widely used in the medical device industry, mainly for testing the push - force performance of prefilled syringes during the injection process. The following is a detailed introduction to its main uses, compliance standards, and technical parameters:

Standards

YY/T 0962 - 2021 Determination of Push - force for Prefilled Syringes, etc.

Main Uses

- Quality Control and Supervision The push - force tester for prefilled syringes is an important tool for medical device manufacturers to conduct product quality control and supervision. Through testing, it can be ensured that the produced prefilled syringes comply with relevant national standards and regulations, thus improving product quality and safety.

- Performance Evaluation and Optimization This tester can be used to evaluate the push - force performance of prefilled syringes of different models and specifications, including parameters such as maximum push - force, minimum push - force, and average push - force. Through the analysis and comparison of test data, it can provide strong support for product performance optimization.

- R & D Support During the R & D process of prefilled syringes, the tester can be used to test the R & D effects and performance improvement of new products. The feedback of test data can help R & D personnel promptly identify problems and make improvements, thereby accelerating the product R & D progress and enhancing product quality.

- Fault Diagnosis and Repair For prefilled syringes with malfunctions, the tester can be used to identify fault points and determine repair solutions. Through the analysis of test data, the causes of faults can be found, and corresponding repair measures can be taken to ensure the normal operation of the equipment.

Technical Parameters

- Force Measuring Range: 0 - 50N (customizable according to actual needs), used to measure the magnitude of the push - force during the injection process of prefilled syringes.

- Force Accuracy: Level 0.5 (error ±0.5%), ensuring the accuracy and reliability of test results.

- Time Setting: Freely set within 0 - 9999 seconds, and the test time can be flexibly adjusted according to test requirements.

- Test Speed: 0.05 - 500mm/min (or customizable according to actual needs), used to control the speed during the injection process to simulate actual usage scenarios.

- Speed Accuracy: Level 1 (error ±1%), ensuring the stability and accuracy of the test speed.

- Nominal Capacity: 0 - 100mL (or customizable according to actual needs), suitable for testing prefilled syringes of different capacities.

- External Dimensions: For example, 300mm×300mm×500mm (the specific dimensions vary depending on the model), facilitating placement and operation.

- Weight: Moderate, easy to carry and move. - Power Supply: Usually 220V, 50Hz (customizable according to local electrical standards), ensuring the normal operation of the tester.

- Standard Configuration: Includes the main unit, a miniature printer, a touch screen, test fixtures, etc., meeting test requirements and providing a convenient operation interface and data recording functions.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Catheter Friction Tester / Catheter Friction Equipment
Catheter Friction Tester / Catheter Friction Equipment Standard YY/T 1536 - 2017 TCAMDI 021 - 2019 Main Uses The catheter friction performance tester is a professional instrument used to detect the ...
Catheter Airflow Resistance Tester
Catheter Airflow Resistance Tester Compliance Standards YY0461 - 2003. etc. Main Uses The catheter airflow resistance tester is an important tool for evaluating the resistance of gas...
Shoelace Abrasion Tester / SATRA TM93 / QB/T2226
Shoelace Abrasion Tester / SATRA TM93 / QB/T2226 Standards SATRA TM93、DIN-4843、QB/T2226、SATRA TM154 Principle Let shoelace cross the eyelet clamped on the fiber board, make the shoelace and eye...
Shoe peeling strength tester BS 20344
Shoe peeling strength tester BS 20344 Product Introduction: Upper peeling strength tester is suitable for testing the peeling strength between the sole and the upper of the shoe, the p...
Catheter Balloon Inflation Diameter Tester
Catheter Balloon Inflation Diameter Tester Standards ISO5367. YY0337.1 - 2002. GB/T15812.1 - 2005. YY 0321.1 - 2009. YY/T 0321.2 - 2021. YY 0321.3 - 2009. and YY0285.6. etc. Main Uses The...
All supplier products

Same products

Bottle Wall and Bottom Thickness Tester
Bottle Wall and Bottom Thickness Tester Seller: Standard International Group (HK) Limited The wall and bottom thickness tester for bottles is a measuring instrument widely used in the pha...
Pinhole Tester / Pinhole Testing Equipment
Pinhole Tester / Pinhole Testing Equipment Seller: Standard International Group (HK) Limited The pinhole tester for aluminum foil is a device specifically used to detect micro - pinholes in ...
Cork Puncture and Chip Detection Instrument
Cork Puncture and Chip Detection Instrument Seller: Standard International Group (HK) Limited The rubber stopper puncture debris detector is a device specifically used to detect the number of...
Aluminum Ointment Tube Toughness Tester
Aluminum Ointment Tube Toughness Tester Seller: Standard International Group (HK) Limited The ductility tester for aluminum tubes is a device specifically used to detect the ductility ind...
Vacuum leak tester / Vacuum leak instrument
Vacuum leak tester / Vacuum leak instrument Seller: Standard International Group (HK) Limited Vacuum Decay Leak Tester specializes in the detection of leaks in ampoules, vials, injection bott...