Automatic Reaction Calorimeter
Standards
GB 51283
GB/T 22232
GB/T 17802
SN/T 3078.1
Product Features
1. It offers three calorimetry methods: heat - flow, power - compensation, and reflux, allowing users to choose according to their needs.
2. It supports multiple operation modes such as isothermal, constant - temperature, and scanning.
3. Optional glass normal - pressure reaction vessels, glass medium - pressure reaction vessels, and metal high - pressure reaction vessels are available.
4. It has an external database, and one system supports the interchange of multiple sets of reaction vessels.
5. With high - power heating and cooling units, it features fast temperature - control response and high - precision exothermic measurement.
6. Automatic feeding control can be achieved by mass or volume measurement.
7. It can accurately measure and obtain process - safety - related data such as reaction heat - flow, reaction enthalpy, conversion rate, specific heat capacity of samples, adiabatic temperature rise, and the maximum temperature that an out - of - control system can reach.
8. The Chinese - language software platform enables flexible programming of experimental procedures, real - time monitoring of key reaction - process data, and online modification of experimental procedures and parameters.
9. It can display the temperature inside the vessel, the temperature of the jacket, the mass of the added materials, and other test status information in real - time.
10. The safety thresholds for key parameters and states can be set. In case of reaction out - of - control, it can be quickly cooled with one click, and it will issue alarms and automatically stop in case of abnormal states, effectively ensuring safety.
11. It can automatically generate and save charts and data, and export experimental analysis reports.
Technical parameters
|
Calorimetry Method |
Heat Flow, Power Compensation (Option), Reflow (Option) |
|
Temperature Control |
|
|
Kettle Temperature Range |
(-25 to 200)°C |
|
Oil Bath Temperature Range |
(-45 to 250)°C |
|
Control Method |
Isothermal, Constant Temperature, Scanning |
|
Temperature Resolution |
1.0mK |
|
Temperature Control Precision |
±0.1K |
|
Silicone Oil Circulation Speed |
(35 to 76)L/min |
|
Control |
|
|
Driver Voltage Range |
(0 to 50)VDC |
|
Driver Maximum Current |
3.0A |
|
Heater Maximum Power |
120W |
|
Atmospheric Pressure Glass Kettle (Option) |
1000mL, other volumes available |
|
Reactor Volume |
Atmospheric Pressure |
|
Working Pressure |
Glass |
|
Reactor Material |
Medium-Pressure Glass Kettle (Option) |
|
Medium-Pressure Glass Kettle (Option) |
|
|
Reactor Volume |
0.6MPa or 1.2MPa |
|
Working Pressure |
Glass |
|
Kettle Material |
316L Stainless Steel or Hastelloy |
|
Kettle Lid Material |
1000mL, other volumes customizable |
|
High-Pressure Metal Reactor ( (Optional) |
10MPa |
|
Reactor volume |
316L Stainless Steel or Hastelloy |
|
Working pressure |
Stirrer |
|
Reactor material |
2000r/min, 3000r/min optional |
|
Stirrer |
|
|
Maximum speed |
Anchor or Paddle |
|
Maximum torque |
PTFE, 316L, or Hastelloy |
|
Stirrer paddle form |
Sampling system |
|
Stirrer paddle material |
Range 3100g, Accuracy 0.01g |
|
Sampling system |
|
|
Precision balance |
Medium-pressure pump: electromagnetic diaphragm pump, the maximum flow rate of 2L / h; high-pressure pump: precision piston pump, the maximum flow rate of 2.4L / h |
|
Sampling channel |
3*400V/50Hz(±10%)/20A |
|
Sampling pump |
7000VA |
|
Other parameters |
1200mm*600mm*1850mm |
|
Power supply |
600mm*700mm*1300mm |
|
Power |
210kg |
|
Test area size |
300kg |
|
Oil bath size |
Heat Flow, Power Compensation (Option), Reflow (Option) |
|
Oil bath weight |
Temperature Control |
|
Total machine weight |
(-25 to 200)°C |
Send product request
Other supplier products
| Battery Isothermal Calorimeter | Battery Isothermal Calorimeter is a professional instrument developed based on the principle of power compensation isothermal calorimetry for testi... | |
| Qinsun SUNTEST CPS+ | A practical desktop xenon lamp equipment with various accessories, customized to meet your SUNTEST needs. Here, you can see SunCool cooling devic... | |
| Safety Footwear Compression Puncture meter | Test purpose Measure the compression resistance of the shoe head cover and the puncture resistance of the steel plate to prevent the operator from... | |
| Internal and external filters | Standards ISO 10526(Standard illuminants for colorimetry, e.g., D65, A light sources) ASTM E1164(Practice for obtaining spectrophotometric data... | |
| Air-cooled Xenon Lamp Aging Tester | Standard Compliance AATCC TM16-2004 Colorfastness to Light AATCC TM16.3 Colorfastness to Light ASTM D2565 Standard Practice for Xenon Arc Expo... |
Same products
| Xenon Test Chamber | Seller: Standard International Group (HK) Limited | Features and Benefits 1.The use of xenon arc lamp as a light source, can simulate the full sunli... | |
| Single Cable Vertical Flame Tester | Seller: Qinsun Instruments Co., LTD | Introduction Single Cable Vertical Flame Tester is used for the vertical flame propagation of a ... | |
| Safety Helmet Flammability Tester | Seller: Qinsun Instruments Co., LTD | Product Introduction: Safety hat flame retardant performance tester for safety hat flame retarda... | |
| Furniture flammability tester | Seller: Qinsun Instruments Co., LTD | Product details Furniture flammability tester is mainly used to test the combustion performance ... | |
| Flame retardant testing machine | Seller: Qinsun Instruments Co., LTD | Feature highlights: Flame Retardant Tester is designed for testing plastic runway surface layers... |