Automatic Reaction Calorimeter
Standards
GB 51283
GB/T 22232
GB/T 17802
SN/T 3078.1
Product Features
1. It offers three calorimetry methods: heat - flow, power - compensation, and reflux, allowing users to choose according to their needs.
2. It supports multiple operation modes such as isothermal, constant - temperature, and scanning.
3. Optional glass normal - pressure reaction vessels, glass medium - pressure reaction vessels, and metal high - pressure reaction vessels are available.
4. It has an external database, and one system supports the interchange of multiple sets of reaction vessels.
5. With high - power heating and cooling units, it features fast temperature - control response and high - precision exothermic measurement.
6. Automatic feeding control can be achieved by mass or volume measurement.
7. It can accurately measure and obtain process - safety - related data such as reaction heat - flow, reaction enthalpy, conversion rate, specific heat capacity of samples, adiabatic temperature rise, and the maximum temperature that an out - of - control system can reach.
8. The Chinese - language software platform enables flexible programming of experimental procedures, real - time monitoring of key reaction - process data, and online modification of experimental procedures and parameters.
9. It can display the temperature inside the vessel, the temperature of the jacket, the mass of the added materials, and other test status information in real - time.
10. The safety thresholds for key parameters and states can be set. In case of reaction out - of - control, it can be quickly cooled with one click, and it will issue alarms and automatically stop in case of abnormal states, effectively ensuring safety.
11. It can automatically generate and save charts and data, and export experimental analysis reports.
Technical parameters
|
Calorimetry Method |
Heat Flow, Power Compensation (Option), Reflow (Option) |
|
Temperature Control |
|
|
Kettle Temperature Range |
(-25 to 200)°C |
|
Oil Bath Temperature Range |
(-45 to 250)°C |
|
Control Method |
Isothermal, Constant Temperature, Scanning |
|
Temperature Resolution |
1.0mK |
|
Temperature Control Precision |
±0.1K |
|
Silicone Oil Circulation Speed |
(35 to 76)L/min |
|
Control |
|
|
Driver Voltage Range |
(0 to 50)VDC |
|
Driver Maximum Current |
3.0A |
|
Heater Maximum Power |
120W |
|
Atmospheric Pressure Glass Kettle (Option) |
1000mL, other volumes available |
|
Reactor Volume |
Atmospheric Pressure |
|
Working Pressure |
Glass |
|
Reactor Material |
Medium-Pressure Glass Kettle (Option) |
|
Medium-Pressure Glass Kettle (Option) |
|
|
Reactor Volume |
0.6MPa or 1.2MPa |
|
Working Pressure |
Glass |
|
Kettle Material |
316L Stainless Steel or Hastelloy |
|
Kettle Lid Material |
1000mL, other volumes customizable |
|
High-Pressure Metal Reactor ( (Optional) |
10MPa |
|
Reactor volume |
316L Stainless Steel or Hastelloy |
|
Working pressure |
Stirrer |
|
Reactor material |
2000r/min, 3000r/min optional |
|
Stirrer |
|
|
Maximum speed |
Anchor or Paddle |
|
Maximum torque |
PTFE, 316L, or Hastelloy |
|
Stirrer paddle form |
Sampling system |
|
Stirrer paddle material |
Range 3100g, Accuracy 0.01g |
|
Sampling system |
|
|
Precision balance |
Medium-pressure pump: electromagnetic diaphragm pump, the maximum flow rate of 2L / h; high-pressure pump: precision piston pump, the maximum flow rate of 2.4L / h |
|
Sampling channel |
3*400V/50Hz(±10%)/20A |
|
Sampling pump |
7000VA |
|
Other parameters |
1200mm*600mm*1850mm |
|
Power supply |
600mm*700mm*1300mm |
|
Power |
210kg |
|
Test area size |
300kg |
|
Oil bath size |
Heat Flow, Power Compensation (Option), Reflow (Option) |
|
Oil bath weight |
Temperature Control |
|
Total machine weight |
(-25 to 200)°C |
Send product request
Other supplier products
| Small Parts meter | Test Procedure: Usage Methods and Interpretations Applicable standards: ASTM F963 EN 71-1 16 CFR Part 1501 ISO 8124-1 Product Advantages: Eff... | |
| Cleveland Open Cup Auto Flash Point Analyser | Products: The instrument complies with ISO2592 "petroleum products of flash and fire assay (Cleveland open cup)," the other standard methods, the ... | |
| Dry and Wet Retroreflectometer | Standards EN ISO 20471:2013 ANSI/ISEA 107-2015 GB 20653-2006 GB/T 18833 Main uses Dry and wet sand abrasive wear testing machine is mainly us... | |
| Gloves Cut Resistance Testing Machine | Safety Glove Cutting Resistance Test Machine and testerfor testing the upper, protective gloves, leather and other materials, cutting strength, sui... | |
| Accelerating Decomposition Temperature Tester | This product complies with "Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria" 28.4.2 Test H.2: Insulated Storage ... |
Same products
| Custom Stainless Components for OEM Applications | Seller: Yongjia County Yaokang Technology Co., Ltd. | Our stainless steel float balls are designed for float valves, water tanks, and industrial liquid... | |
| FH-77 Dissolved hydrogen meter | Seller: Kelilong Electron Co.,Ltd | Pen type dissolved hydrogen detector / dissolved hydrogen meter: used to measure the dissolved hy... | |
| Xenon Arc Weather Ometer | Seller: Standard International Group (HK) Limited | Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ... | |
| Xenotest | Light Fastness Tester Si220 (SunTest) | Seller: Standard International Group (HK) Limited | Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ... | |
| Ozone Aging Chamber | Seller: Standard International Group (HK) Limited | Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum... |