GF6018A CLAMP TYPE MULTIMETER CALIBRATOR
DESCRIPTIONThe GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected with PC to control, become automatic verification system. It has precise interface and multi-functions including verification, storage and query. The GF6018A multimeter calibrator adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics. It fully meets ISO17025 laboratory standards and is a good ideal test equipment for electrical engineers.
APPLICATION
■ Power plant;
■ Universities;
■ Panel manufacturer;
■ Research institutes;
■ Electrical testing center;
■ Multimeter manufacturers;
■ Oscilloscope manufacturer;
■ Clamp meter manufacturers;
■ Digital meter manufacturers;
■ ISO17025 Electrical laboratory;
■ Electricity power bureau & power company;
■ Power engineering commissioning company;
■ Electrical Department of industrial and mining enterprises;
FEATURES
■ With 200A, 600A, 1000A calibration coil;
■ High precision AC/DC voltage source & current source;
■ Because of light weight, this device is more suitable for field use;
■ With RS-232 interface, this calibrator is controlled by PC software(optional;
■ Automatic or manual inspection, and the results are processing and management;
■ Has a non-volatile memory, Storage 500groups of the test data, for access and upload;
■ It can be semi-automatic or manual inspection of analog multimeter, clamp type current meter, all kinds of electric meter, (voltmeter, ammeter, frequency meters, resistance meter) basic error;
■ The calibrator can be generated with 2-31 harmonic wave, harmonic number, order, amplitude and harmonic phase of fundamental wave can be programmed;
■ Power amplifier working frequency range is 40Hz-1KHZ, has a good linear. Current amplifier is constant current source; voltage amplifier is constant voltage source;
PARAMETERS
Electrical parameters | ||
---|---|---|
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60HzAC | |
AC Voltage output | ||
range | 200mV, 400mV, 2000mV, 4000mV, 20V, 100V, 200V, 500V, 1000V; max 1050V |
|
Range 20V-1000V | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 200mV-4000mV | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS (1000V not included) | |
Fineness | 5×10-5 | |
AC Current Output | ||
Range | 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A; max 24A | |
Range 0.2A-20A | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 2mA-40mA | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS | |
Fineness | 5×10-5 | |
Frequency Output | ||
Range | 45-65Hz | |
Fineness | 0.001Hz | |
Accuracy | 0.002Hz | |
Harmonic Wave | ||
Times | 2-31 | |
Extent | 0-20% | |
Each harmonic phase fineness | 0.01·N (N is harmonic order) | |
DC voltage output | ||
Range | 200mV, 400mV, 2000mV, 4000mV, 20V, 40V, 100V, 200V, 400V, 1000V; max 1050V |
|
Load capacity | 20W | |
Adjustable range | 0-110% FS (1000V not included) | |
Adjustable fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.03%RD+0.02%FS) | |
Ripple wave | ≤1% FS | |
DC current output | ||
Range | 20uA, 40uA, 200uA, 400uA, 2mA, 4mA, 20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A; max 22A |
|
Load capacity | 20W | |
Adjustable Range | 0-110% FS (1000V not included) | |
Adjustable Fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.06%RD+0.04%FS) | |
Ripple wave | ≤1% FS | |
Resistance box | ||
Range | 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10 kΩ, 20kΩ, 50KΩ, 100kΩ, 200kΩ, 500kΩ, 1MΩ, 2MΩ, 5MΩ, 10MΩ, 20MΩ | |
Fineness | 0.02% | |
Adjustable Range | 0-100%FS | |
Accuracy | ±(0.3%RD+0.2%FS) | |
Clamp meter range | ||
200A | Accuracy | ±0.2% |
600A | Accuracy | ±0.5% |
1000A | Accuracy | ±1% |
Dot frequency square wave output | ||
Range | 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz | |
Square wave amplitude | 4.5V | |
Setting accuracy | 5×10-5 | |
Communication Port | ||
Communication Port | RS232, USB | |
Standard | ||
Standard | JJG124-2005; JJF1587-2016; IEC61010, IEC 61000, IEC 61326 | |
Safety | ||
Isolation protection | IEC 61010-1:2001 | |
Measurement Category | 300 V CAT III, 600 V CAT II | |
Degree of protection | IP20 | |
Declaration of conformity | CE, CNAS certified | |
Mechanical parameters | ||
Dimension (L×W×H) (mm) | 440x360x160 | |
Weight (kg) | 12 | |
Environmental conditions | ||
Operating temperature | 20°C±10°C | |
Storage conditions | -30°C to 60°C | |
Relative humidity | ≤85%RH | |
(1) FS means range, the same as below; Support customization |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
пожалуйста | GF112D является 0,05, 0,1 или 0,2, Из-за того, что вы сказали, что у вас проблемы с самооценкой? И я не могу просто так взять и уйти. apparent powe... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | This GF6018A high precision multi-product calibrator is compliance with national verification regulation: JJG124-2005 "Ammeter, voltmeter, power me... | |
GF112D 1-PHASE ELECTRICITY METER TESTER | TheGF112D is a portable one-phase power meter tester. It used for testing the error of single-phase power meter on spot. It can test harmonic,power... | |
D20: voltage output 200A AC/DC CURRENT PROBE | The Model D20 AC/DC current clamp is a portable 100A/200Arms current probe.The D20 is power by a rechargeable multimeter battery or from a 9 V powe... | |
GF312B2 PORTABE 3-PHASE REFRENCE METER WITH CLAMP ON CT | GF312B2 portable three phase reference meter high accuracy 0.02%, with all kinds of optional clamp on ct and smart optical sampler. It can be appli... |
Похожие товары
330037 Communication Unit Change-Over Table HS50 Original Used | Продавец: Guangdong Juguangheng Automation Equipment Co.,Ltd. | Robot Mobile Screen Protector Making Machine Parts CP40 N045 Nozzle NXT III H08M 10.0 Nozzle RM A... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | Продавец: 782364 | This GF6018A high precision multi-product calibrator is compliance with national verification reg... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | Продавец: 782364 | DESCRIPTIONThe GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected w... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | Продавец: 782364 | This GF6018A high precision multi-product calibrator is compliance with national verification reg... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | Продавец: 782364 | APPLICATION ■ Power plant; ■ Universities; ■ Panel manufacturer; ■ Research institutes; ■ Electr... |