faraday cage of HV transformer PD test

faraday cage of HV transformer PD test

Application:

HV test shielding room (faraday cage) areWidely used in power cable, transformer, transformer switch, transformer substation and other High voltage levels of partial discharge test or impulse test.

Technical parameters:

ØFaladay cage Size:17.5m×7.5m×6m(height)

ØControl room :3m×2m×3m

ØMotor driven airtight swing door :2.5×2.5(H)m,upper transmission

ØShielding and grounding of Faraday Cage: it is a 6 surface shielding body,overall electrical connection among these 6 surface,multipoint grounding of main body.

ØEfficiency after electromagnetic shielding (to meet requests for PD testing )

  1. ≥60dB;

ØBackground noise:< 5PC

ØGrounding resistance of grounding electrode:< 0. 5Ω(by B&D ready )

ØThere are 6 air-vents on top of roof.

ØThere is a switch box in cage but at one meter above ground.

ØThere are 9 lighting on roof,itsilluminationwill be morn than 250lksat one meter above ground.

ØPower supply into Faraday cage will be equipped filter.

ØAbout ground connection wire :indoor ground copper bar

ØSurface of Main body will be galvanized sheet and electrostatic

Øspraying on surface.its craft and material meets China national standard.

ØTo meet the requirements of design and maintain,steel sheet split mounting type structure will be adopted.

Structure introduction

  1. Main body
  • Main body will be installed on the ground of workshop. There is a small gradient at doorsill with convenient test object come in and out.
  • Shielding shell are stamping 1.5mm reliable galvanized steel sheets.well-regulated installing holes are arranged on contact surface.
  • Conductive article linings with spring and Galvanic corrosion resistance will be put between touching surface of steel sheets.
  • Fastener are M8 galvanize screws.
  • 40 mm spun glass sound-absorbing cotton will be put between shielding sheet and indoor adornment layer to reduce noise resound.
  • External surface of main body are structural steel keel,the roof are reinforced truss bridge to enhance rigidity and antiknock.
  1. Masking Door
  • It is a motor driven airtight swing door with upper transmission
  • Its controlling is PLC controlling, voltage is 24V.energy conservation ,safe and reliable grounding.
  • Infrared ray brake device will be set on both sides.
  • Electrical lock will be installed on masking door. while testing will be making,if someone going, the system will stop running.
  1. Ventilating

There are 6 Ventilation waveguide window on top of roof. Size are300×300×50mm.

  1. Filter and power supply
  • Power supply should be filtering . a LV high frequency filter will used to wipe out electromagnetic noise.
  • Plug seat will be on surface of wall. All cables will go through by galvanized steel pipe.
  • Control room will locate in Faraday cage, size is 3×2×3(H)m.structural steel frame construction.
  • There is a rectangle observation window on the wall of control room. Terrain clearance is 800mm.
  • Window material is 5㎜+5㎜toughened glass.shielding copper net will be between two layers of glass.
  • Copper net will be welded on window frame.
  • Window frame and copper net with a reliable ground connection.
  • There are 2 sets of stainless steel grille lamp in control room.
  • Sever Plug seats will be set on the wall of control room.
  • One set of air condition n control room.(completed by B&D ).
  • The wall of control room will be Double facedaluminum plastic board,the floor are all-steel anti-static raised floor.

4 . Grounding

  • Ground resistance of grounded screen should less than 0. 5Ω, it will be ready by B&D.
  • 2 ground connection copper plates should be put as grounding electrode of testing device.

Top lighting lamp locate on the roof.nine of 250W metal halogen lamp. (3 group).

  • Roof: Micropore-aluminium alloy sheet.combustibility is class A.lining are sound absorption inflaming retarding paper.feature: no dust,no dust absorption and easy dismounting.
  • Wall:wall surface are 0.6mmaluminium zinc plate(Punching Abatvoix) ,Plastic-sprayed surface.
  • Floor: placing concrete,epoxy terrace. Thickness should more than 3mm. (floor will be completed by B&D).

Due to increased environmental electromagnetic pollution, sensitive and accurate measurements are often affected by RF noise. The application of CNME Intermational Shielding Room provide the highest possible shielding attenuation, creating a controlled electromagnetic environment to perform high sensitive testing without distortion. If you are interested in our Faraday Cage, you can call us now.


Отправить запрос, связаться с поставщиком

Кому: CNME Intermational Co.Ltd
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

 Energy meter calibration -- CNKP-S3000 Three phase 5 position 0.05% Accuracy 0-120A
Energy meter calibration -- CNKP-S3000 Three phase 5 position 0.05% Accuracy 0-120A Energy meter calibration -- CNKP-S3000 Three phase 5 position 0.05% Accuracy 0-120A KP-S3000 three phase energy meter test bench is a new generati...
Tansformer Insulation Testing  Station design
Tansformer Insulation Testing Station design Tansformer Insulation Testing Station design We will be willing to provide whole-process engineering consulting servicesfor you: Preparingfeasibili...
Oil immersed Current transformer
Oil immersed Current transformer Oil immersed Current transformer main parameter of 69kv CT Rated current ratio: 2000/1600/1500/1200/1100/800/500/400/300 : 5 A Rated output capaci...
DC voltage test system
DC voltage test system DC voltage test system DC test systems are used to test components and complete systems found in electrical power supply systems and operating on D...
Mobile substation
Mobile substation Mobile substation Performance characteristics ① Rapid allocation: connections between equipments are connected .After connected to earth system and...
Все товары поставщика

Похожие товары

Air insulated Dry type transformer VPI
Air insulated Dry type transformer VPI Продавец: Power transformer Air insulated Dry type transformer VPI TAILI SG(B) air-barrier dry-type transformer( VPI) is des...
Cast Resin Dry Type Transformer with Cooling Fan
Cast Resin Dry Type Transformer with Cooling Fan Продавец: Power transformer Cast Resin Dry Type Transformer with Cooling Fan Taili’s advanced epoxy resin casting pr...
1250kVA Dry type Transformer for Bangladesh
1250kVA Dry type Transformer for Bangladesh Продавец: Power transformer 1250kVA Dry type Transformer for Bangladesh Taili's advanced epoxy resin casting process ensures...
35kV Dry-type transformer with OLTC
35kV Dry-type transformer with OLTC Продавец: Power transformer 35kV Dry-type transformer with OLTC Taili's35kV Dry-type Transformer with OLTC (On-Load Tap Chan...
Cast Resin Dry Type Transformer
Cast Resin Dry Type Transformer Продавец: Power transformer Cast Resin Dry Type Transformer IEC/ANSICast Resin TransformersfromTAILI Electric, is difference...