Type MP-GC Three-Conductor Mine Power Feeder Cable, PVC Jacket, 15kV ICEA S-75-381
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable fordirect burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationCross-Linked Polyethylene (XLPE).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketPolyvinyl Chloride (PVC), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeNominal Insulation ThicknessNominal Jacket ThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×47880.092.30.112.81.4135.×27680.092.30.112.81.4737.×119580.092.30.112.81.5439.×1/019480.092.30.112.81.6341.×2/019380.092.30.112.81.7243.×3/019280.092.30.143.61.8948.×4/019180.092.30.143.62.0151.×250371/080.092.30.143.62.1053.×350372/080.092.30.143.62.3158.×500374/080.092.30.143.62.5965.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Другие товары поставщика
|
VDE 0295 400Hz Airport Cables 7-core |
VDE 0295 400Hz Airport Cables 7-core
Applications
These cables are designed for 400 Hz systems for power supply of aircraft, computer systems and r... |
|
PE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2Y(St)HSWAH |
PE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2Y(St)HSWAH 90°C / 300VSTANDARDSBa... |
|
Type MP-GC Three-Conductor Mine Power Feeder Cable, PVC Jacket, 15kV ICEA S-75-381 |
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections bet... |
|
FLGG airfield lighting cable |
FLGG airfield lighting cable
Applications
These cables are used as airfield lighting cable for secondary electrical circuits.
Standards
IEC 60502-2... |
|
LYST/LYAR airfield lighting cable |
LYST/LYARairfield lighting cable
Applications
LYST airport cables are used for connection between control tower and constant current regulators (CC... |
Все товары поставщика