Type MP-GC Three-Conductor Mine Power Feeder Cable, PVC Jacket, 15kV ICEA S-75-381

Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable fordirect burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationCross-Linked Polyethylene (XLPE).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketPolyvinyl Chloride (PVC), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeNominal Insulation ThicknessNominal Jacket ThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×47880.092.30.112.81.4135.×27680.092.30.112.81.4737.×119580.092.30.112.81.5439.×1/019480.092.30.112.81.6341.×2/019380.092.30.112.81.7243.×3/019280.092.30.143.61.8948.×4/019180.092.30.143.62.0151.×250371/080.092.30.143.62.1053.×350372/080.092.30.143.62.3158.×500374/080.092.30.143.62.5965.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Other supplier products
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable, PVC Jacket, 15kV ICEA S-75-381 |
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections bet... |
|
|
FAA L-824 Type C 600V Airport Cable |
FAA L-824 Type C 600VAirport Cable
Applications
These cables are designed for use in airport lighting and control circuits, suitable for installat... |
|
|
[FA-] MPYS, MPYCS, MPYCYS |
50V [FA-] MPYS,Website:, MPYCS, MPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed ... |
|
|
VDE Standard Industrial Cables H07ZZ-F |
VDE Standard Industrial Cables H07ZZ-F
Application and DescriptionThese LSZH cables are flexible,Website:, mainly used for mobile service, suitable... |
|
|
FAA L-824 Type C Unshielded 5kV Airport Cable |
FAA L-824 Type C Unshielded 5kV Airport Cable
Applications
These cables are used for interconnecting the transformers and the current regulator of ... |