ct pt analyzer HYVA-405
|
Tests for Current Transformer: 1 Excitation curve and parameters test Tests for Voltage Transformer: 1 Turns ratio test |
| CT PT Tester application 1 CT nameplate check 2 CT parameters check in work burden 3 CT transient parameters analysis 4 CT ratio and phase error calibration 5 PT routine test |
| 1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 2 Power supply: AC220V±10%, 50/60Hz±10% 3 Voltage output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output: 500VA 6 Maximum knee voltage measurement: 45KV 7 Current measurement: Range: 0~10A (automatically change range in 0.1/0.4/2/10A) Error: <±0.1%+0.01%FS 8 Voltage measurement: Range: 0~200V (automatically change range in 1V/10V/70V/200V) Error: < ±0.1%+0.01%FS 9 Turns ratio measurement: Range:1~35000 1~2000 error<0.05% 2000~5000 error<0.1% 5000~35000 error<0.2% 10 Phase measurement: error: ±2min; resolution: 0.01min 11 Winding resistance measurement: Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error: < 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ 12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree 13 CT Secondary burden: Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error: <0.2%RDG+0.02%FS Maximum resolution: 0.001ohm 14 PT Secondary burden: Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range: 1~35000 1~10000 error<0.1% 10000~35000 error<0.2% 16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1% 17 PT phase angle measurement: maximum error < 3min 18 Make evaluation for test results according to selected standards 19 Make word report for test result 20 Make word reports one time for multi-group test records on the PC 21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test 22 Compare excitation curves with saved excitation curves in the same window 23 Memory capacity: >1000 groups test results 24 Working condition: temperature: -10℃~50℃; moist: ≤90% 25 Size: 485mm×356mm×183mm 26 Weight: <15kg |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| HYKC-2000 On Load Tap Changer Ohmmeter Analyzer | 1.Introduction On load tap changer analyzer HYKC-2000 is mainly applied to test transient time, transition waveform, transition resistance, sync... | |
| circuit breaker analyzer HYGK-307 | Circuit breaker analyzer introduction: 1) Measurement of closing time, opening time, time spread between poles, time spread between units of one p... | |
| YJJ-ⅡInsulating Oil Tester | Dielectric oil tester functions: 1 Breakdown test of user-defined2 Proof test3 Calibration interface for customers4 Result print Insulating oil tes... | |
| Dry Type Hipot Tester | Introduction HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high v... | |
| HY2303 Insulation Tester | Rated Voltage 2500V 5000V 10000V Measuring Range 0.0~99.9MΩ100~999MΩ1.00~9.99GΩ10.0~100GΩ 0.0~99.9MΩ100~999M&O... |
Похожие товары
| Common Rail Injector Nozzle 880P119092 | Продавец: China lutong | Common Rail Injector Nozzle 880P119092 Common Rail Injector Nozzle A6510702887Chris Whats/ app:+... | |
| Bently Nevada AC Power Supply PN 127610-01 of 3500/15 | Продавец: 840499 | 3500/15 127610-01 | Bently Nevada | 3500/15 交流电源模块(停产。新替代品:106M1079-01:通用交流电源模块)3500/15 127610-01... | |
| Тоннельный контейнерный трансформатор | Продавец: 839459 | Трансформатор коробчатого типа, предназначенный для туннелей, представляет собой продукт, специал... | |
| Металлическое бронированное роторное распределительное устройство АС 35KV KYN40.5 для помещений | Продавец: 839459 | Металлическое бронированное роторное распределительное устройство АС 35KV KYN40.5 адаптировано к ... | |
| Аctive Filter Cabinet | Продавец: 839459 | SVG: обеспечение электрической безопасности посредством национальных стандартов тестирования. |