ct pt analyzer HYVA-405
Tests for Current Transformer: 1 Excitation curve and parameters test Tests for Voltage Transformer: 1 Turns ratio test |
CT PT Tester application 1 CT nameplate check 2 CT parameters check in work burden 3 CT transient parameters analysis 4 CT ratio and phase error calibration 5 PT routine test |
1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 2 Power supply: AC220V±10%, 50/60Hz±10% 3 Voltage output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output: 500VA 6 Maximum knee voltage measurement: 45KV 7 Current measurement: Range: 0~10A (automatically change range in 0.1/0.4/2/10A) Error: <±0.1%+0.01%FS 8 Voltage measurement: Range: 0~200V (automatically change range in 1V/10V/70V/200V) Error: < ±0.1%+0.01%FS 9 Turns ratio measurement: Range:1~35000 1~2000 error<0.05% 2000~5000 error<0.1% 5000~35000 error<0.2% 10 Phase measurement: error: ±2min; resolution: 0.01min 11 Winding resistance measurement: Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error: < 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ 12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree 13 CT Secondary burden: Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error: <0.2%RDG+0.02%FS Maximum resolution: 0.001ohm 14 PT Secondary burden: Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range: 1~35000 1~10000 error<0.1% 10000~35000 error<0.2% 16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1% 17 PT phase angle measurement: maximum error < 3min 18 Make evaluation for test results according to selected standards 19 Make word report for test result 20 Make word reports one time for multi-group test records on the PC 21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test 22 Compare excitation curves with saved excitation curves in the same window 23 Memory capacity: >1000 groups test results 24 Working condition: temperature: -10℃~50℃; moist: ≤90% 25 Size: 485mm×356mm×183mm 26 Weight: <15kg |
在线联系供应商
Other supplier products
HYGS Tan Delta Tester | 1PowerFactor Testerapplication HYGS automatic tangent delta tester is applied to measure the dielectric loss and capacitor value of insulation mat... | |
circuit breaker analyzer HYGK-307 | Circuit breaker analyzer introduction: 1) Measurement of closing time, opening time, time spread between poles, time spread between units of one p... | |
FRC series High Voltage Divider | Application FRC series high voltage divider is applied to measure AC/DC high voltage in metrology department of power system or high voltage test.... | |
HYEC-10 digital radio phase detectors | 1.Display:phase angle, frequency, voltage waveform 2.Bring Rechargeable Battery 3.Patented product, Simple maintenance 4.Acquisition of signal i... | |
ZGF DC High Voltage Generator | ZGF DC high voltage generator is DC high voltage power supply equipment which is applied in power cable test and arrester test in power system. ... |
Same products
Bently Nevada AC Power Supply PN 127610-01 of 3500/15 | 卖方: 840499 | 3500/15 127610-01 | Bently Nevada | 3500/15 交流电源模块(停产。新替代品:106M1079-01:通用交流电源模块)3500/15 127610-01... | |
隧道专用箱变 | 卖方: 839459 | 隧道专用箱变是针对在隧道环境中使用而专门设计的产品,针对隧道内湿度大,运行空间狭小等特殊性,该产品采用全密封双层隔温分体式箱体,配备凝露控制器与温度控制器,实现实时监控与自启动的功能,有效保证隧... | |
交流金属铠装移开式开关设备 | 卖方: 839459 | KYN61-40.5铠装移开式交流金属封闭开关设备适应于三相交流50Hz电力系统,用于发电厂,变电所及工矿企业的配电室接受和分配电能之用,并对电路实行控制、保护及监测。 使用环境 ►环境温度:最... | |
有源滤波柜 | 卖方: 839459 | 有源滤波:与业内知名元器件厂家合作,为电力节能及谐波治理提供优质解决方案 | |
直流屏 | 卖方: 839459 | SVG:通过国家检验标准,为用电安全做保障。 |