ct pt analyzer HYVA-405
Tests for Current Transformer: 1 Excitation curve and parameters test Tests for Voltage Transformer: 1 Turns ratio test |
CT PT Tester application 1 CT nameplate check 2 CT parameters check in work burden 3 CT transient parameters analysis 4 CT ratio and phase error calibration 5 PT routine test |
1 Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13 2 Power supply: AC220V±10%, 50/60Hz±10% 3 Voltage output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output: 500VA 6 Maximum knee voltage measurement: 45KV 7 Current measurement: Range: 0~10A (automatically change range in 0.1/0.4/2/10A) Error: <±0.1%+0.01%FS 8 Voltage measurement: Range: 0~200V (automatically change range in 1V/10V/70V/200V) Error: < ±0.1%+0.01%FS 9 Turns ratio measurement: Range:1~35000 1~2000 error<0.05% 2000~5000 error<0.1% 5000~35000 error<0.2% 10 Phase measurement: error: ±2min; resolution: 0.01min 11 Winding resistance measurement: Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error: < 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ 12 Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree 13 CT Secondary burden: Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error: <0.2%RDG+0.02%FS Maximum resolution: 0.001ohm 14 PT Secondary burden: Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range: 1~35000 1~10000 error<0.1% 10000~35000 error<0.2% 16 PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1% 17 PT phase angle measurement: maximum error < 3min 18 Make evaluation for test results according to selected standards 19 Make word report for test result 20 Make word reports one time for multi-group test records on the PC 21 Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test 22 Compare excitation curves with saved excitation curves in the same window 23 Memory capacity: >1000 groups test results 24 Working condition: temperature: -10℃~50℃; moist: ≤90% 25 Size: 485mm×356mm×183mm 26 Weight: <15kg |
Send product request
Other supplier products
Oil Type Hipot Tester | HIPOT Tester is applied in power system for insulation test of high voltage equipment. The typical application of the HIPOT tester is as follo... | |
HYYJ-502A Insulating oil tester | Portable dielectric oil tester technical index: (1) AC220V±10% power supply input (2) Output voltage:AC 0V~100KV (3) Rate of voltag... | |
ct pt analyzer HYVA-405 | Introduction Tests for Current Transformer: 1 Excitation curve and parameters test2 Turns ratio test3 Ratio and phase error test4 Polarity mar... | |
HYPCIT Primary current injection tester | Introduction: HYPCIT series primary current injection tester is applied in power system for circuit breaker test, protection system test and curre... | |
SLQ Primary Current Injection Test Set | Introduction: SLQ primary current injection test setis a high current generator instrument. It is applied in current transformer test, circuit bre... |
Same products
Bently Nevada AC Power Supply PN 127610-01 of 3500/15 | Seller: 840499 | 3500/15 127610-01 | Bently Nevada | 3500/15 交流电源模块(停产。新替代品:106M1079-01:通用交流电源模块)3500/15 127610-01... | |
Tunnel special box transformer | Seller: 839459 | Tunnel special box transformer is a product specially designed for use in the tunnel environment.... | |
AC Metal Аrmored Movable Switchgear 35KV KYN40.5 in-hous | Seller: 839459 | KYN61-40.5 armored movable AC metal enclosed switchgear is suitable for three-phase AC 50Hz power... | |
Аctive Filter Cabinet | Seller: 839459 | Аctive filter: сollaborating with well-known component manufacturers in the industry to provide h... | |
SVG | Seller: 839459 | SVG: ensuring electricity safety, passing national testing standard. |