.

GK600 Sensorless Vector Control Frequency Inverters

GK600 Series General Purpose Frequency Inverter GK600 Series General Purpose Frequency Inverter,Website:, adopting advanced sensorless vector control technology with robust sensorless vector control, precise sensorless vector control, and different V/f curves programmable, are widely applied to various industrial sectors. GK600 series Frequency Inverter are competitive in market with comprehensive advantages, such as its widely-used characteristics, favorable performance-price ratio, and easier operation and maintenance for users, etc.1.Model Explanation 2.Nameplate Information 3.Information of Product Model3AC 380V/400V/415V/440V/460V/480V -10%~10%, 50Hz/60Hz -5%~5% Variable Frequency Drive model Power rating (kW) Rated output current (A) Rated input current (A) Applicable motor (kW) Brake unit GK600-4T2.2G/3.7LB 2.2G 2.2 5.5 9.2 2.2 Built-in 3.7L 3.7 9 14.9 3.7 GK600-4T3.7G/5.5LB 3.7G 3.7 9 14.9 3.7 5.5L 5.5 13 21.5 5.5 GK600-4T5.5G/7.5LB 5.5G 5.5 13 21.5 5.5 7.5L 7.5 17 27.9 7.5 GK600-4T7.5G/11LB 7.5G 7.5 17 27.9 7.5 11L 11 24 39 11 GK600-4T11G/15LB 11G 11 24 39 11 15L 15 30 50.3 15 GK600-4T15G/18.5LB 15G 15 30 50.3 15 18.5L 18.5 39 60 18.5 GK600-4T18.5G/22L(B)* 18.5G 18.5 39 60 18.5 Built-in optional 22L 22 45 69.3 22 GK600-4T22G/30L(B)* 22G 22 45 69.3 22 30L 30 60 86 30 GK600-4T30G/37L(B)* 30G 30 60 86 30 37L 37 75 104 37 GK600-4T37G/45L(B)* 37G 37 75 104 37 45L 45 91 124 45 GK600-4T45G/55L(B)* 45G 45 91 124 45 55L 55 112 150 55 GK600-4T55G/75L 55G 55 112 150 55 Externally mounted when needed 75L 75 150 201 75 GK600-4T75G/90L 75G 75 150 201 75 90L 90 176 236 90 GK600-4T90G/110L 90G 90 176 160** 90 Externally mounted when needed 110L 110 210 192** 110 GK600-4T110G/132L 110G 110 210 192** 110 132L 132 253 232** 132 GK600-4T132G/160L 132G 132 253 232** 132 160L 160 310 285** 160 GK600-4T160G/185L 160G 160 310 285** 160 185L 185 350 326** 185 GK600-4T185G/200L 185G 185 350 326** 185 200L 200 380 354** 200 GK600-4T200G/220L 200G 200 380 354** 200 220L 220 430 403** 220 GK600-4T220G/250L 220G 220 430 403** 220 250L 250 470 441** 250 GK600-4T250G/280L 250G 250 470 441** 250 280L 280 520 489** 280 GK600-4T280G/315L 280G 280 520 489** 280 315L 315 590 571** 315 GK600-4T315G/355L 315G 315 590 571** 315 355L 355 650 624** 355 GK600-4T355G/400L 355G 355 650 624** 355 400L 400 725 699** 400 GK600-4T400G/450L 400G 400 725 699** 400 450L 450 820 790** 450 1AC/3AC 208V/220V/230V 50/60Hz -10%~10%, 50Hz/60Hz -5%~5% Variable Frequency Drive model Power rating (kW) Rated output current (A) Applicable motor (kW) Brake unit GK600-2T0.4B 0.4 2.6 0.4 Built-in GK600-2T0.75B 0.75 4.5 0.75 GK600-2T1.5B 1.5 7.5 1.5 GK600-2T2.2B 2.2 11 2.2 GK600-2T3.7B 3.7 17 3.7 GK600-2T5.5B 5.5 25 5.5 GK600-2T7.5B 7.5 33 7.5 GK600-2T11(B) 11 45 11 Built-in optional GK600-2T15(B) 15 60 15 GK600-2T18.5(B) 18.5 73 18.5 GK600-2T22(B) 22 96 22 GK600-2T30 30 112 30 Externally mounted when needed GK600-2T37 37 144 37 GK600-2T45 45 176 45 GK600-2T55 55 210 55 GK600-2T75 75 288 75 GK600-2T90 90 310(350) 90 GK600-2T110 110 415 110 * means brake unit is optional built-in. Take 18.5G/22L for example: the model without brake unit is GK600-4T18.5G/22L, and the model with brake unit is GK600-4T18.5G/22LB. Braking resistor needs to be mounted externally with reference to Table 3-3.** means the rated input current configured a DC reactor. The drive GK600-4T90G/110L or above is provided with an external-mounted DC reactor in shipment as default. Be sure to connect the DC reactor. Failure to comply may result in drive abnormal running. 4.Technical Features of GK600 Frequency Inverter Table 3 Technical Features of GK600 Frequency Inverter Power input Rated input voltage 3-phase AC208V/220V/230V/240V/380V/400V/415V/440V/460V/480V 1-phase AC220V/AC230V/AC240V Rated input current See Section 2.3 in the User Manual Frequency 50Hz/60Hz, tolerance ±5% Allowable range of voltage Continuous voltage fluctuation ±10%, short fluctuation -15%~+10%, i.e. 323V~528V; Voltage out-of-balance rate <3%, distortion rate as per the requirements of IEC61800-2 Power output Standard applicable motor (kW) See Section 2.3 in the User Manual Rated current (A) See Section 2.3 in the User Manual Output voltage (V) 3-phase: 0~ rated input voltage, error < ±3% Output frequency (Hz) 0.00~ 600.00Hz; unit: 0.01Hz Overload capacity 150% - 1min; 180% - 10s; 200% - 0.5s Control characteristics V/f patterns V/f control Sensor-less vector control 1 Sensor-less vector control 2 Range of speed regulation 1:100 ( V/f control, sensor-less vector control 1) 1:200 (sensor-less vector control 2) Speed accuracy ±0.5% (V/f control) ±0.2% (sensor-less vector control 1 & 2) Speed fluctuation ±0.3% (sensor-less vector control 1 & 2) Torque response  < 10ms (sensor-less vector control 1 & 2) Starting torque 0.5Hz: 180% (V/f control, sensor-less vector control 1) 0.25Hz: 180% (sensor-less vector control 2) Basic functions Start frequency 0.00~ 600.00Hz Accel/Decel time 0.00~60000s Carrier frequency 0.7kHz~16kHz Frequency setting sources Digital setting + keypad ∧/∨ Digital setting + terminal UP/DOWN Communication Analog setting (AI1/AI2/EAI) Terminal pulse setting Motor started methods Started from starting frequency DC braking and then started Speed search started Motor stopped methods Ramp to stop Coast to stop Ramp stop + DC brake Basic functions Dynamic braking capacity Brake unit action voltage: 650V~750V; service time: 0.0~100.0s; brake units for GK600-4T45G/55L and below are built in or can be built in. See table 2-1 DC braking capacity DC braking start frequency: 0.00~600.00Hz DC braking current: 0.0~100.0% DC braking time: 0.0~30.00s Input terminals 6 digital inputs, one of which can be used for high-speed pulse input. Compatible with active open collectors NPN, PNP and dry contact input. Digital inputs can be extended to 7 2 analog inputs, one of which is voltage/current programmable, and the other supports voltage only. Analog inputs can be extended to 3, and the extended one is voltage/current programmable Output terminals 1 high-speed pulse output, 0~50kHz square wave signal output; can output signals such as command frequency, or output frequency, etc. 1 digital output 1 relay output (can be extended to 2) 1 analog output (can be extended to 2), voltage/current output programmable; can output signals such as setting frequency, or output frequency, etc Featured functions Parameter copy, parameter backup, common DC bus, free switchover between two motors’ parameters, flexible parameter displayed & hidden, various master & auxiliary command and switchover, speed search started, a variety of Accel/Decel curves optional, automatic correction of analog, contracting brake control, 16-step speed control programmable (2-step speed supports flexible frequency command), wobble frequency control, fixed length control, count function, three faults recorded, over excitation brake, over voltage stall protection, under voltage stall protection, restart upon power loss, skip frequency, frequency binding,four kinds of Accel/Decel time, motor thermal protection, flexible fan control, process PID control, simple PLC, multi-functional key programmable, droop control, parameter identification, field-weakening control, high-precision torque restraint, V/f separated control Protection functions Refer to Chapter 7- Troubleshooting in the User Manual Environment Place of operation Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water drop or salt, etc. Altitude 0~2000m De-rate 1% for every 100m when the altitude is above 1000 meters Ambient temperature -10℃~50℃ Relative humidity 0~95%, no condensation Vibration Less than 5.9m/s2 (0.6g) Storage temperature -40℃~+70℃ Others Efficiency at rated Amps Rated power 7.5kW and below: ≥93% 11~ 45kW: ≥ 95%   5kW and above: ≥98% Installation Wall-mounted IP grade IP20 Cooling method Fan cooled Control Board Diagram Wiring Diagram Control Terminal Specification Control terminal specification Category Terminal Terminal designation Specification Analog input +10V Analog input  reference voltage 10.3V ±3% Maximum output current 25mA  The resistance of external potentiometer should be larger than 400Ω GND Analog ground Isolated from COM interiorly AI1 Analog input 1 0~20mA: input impedance - 500Ω, maximum input current - 25mA 0~10V: input impedance - 100kΩ, maximum input voltage - 12.5V Switch S2 on control board for jumping from 0~20mA and 0~10V, factory default: 0~10V AI2 Analog input 2 -10V~10V: input impedance - 25kΩ Range: -12.5V~+ 12.5V Analog output AO1 Analog output 1 0~20mA: impedance - 200Ω~500Ω 0~10V: impedance ≥ 10k Switch S3 on control board for jumping between 0~20mA and 0~10V, factory default: 0~10V GND Analog ground Isolated from COM interiorly Digital input +24V +24V 24V±10%, Isolated from GND interiorly Maximum load - 200mA PLC Digital input  Common terminal Used for switching between high and low levels, short-circuited with +24V when delivery, i.e. low value of digital input valid External power input COM +24V ground Isolated from GND interiorly X1~X5 Digital input  Terminals 1~5 Input: 24VDC, 5mA Range of frequency: 0~200Hz Range of voltage: 10V~30V X6/DI Digital input/pulse input Digital input: same as X1~X5 Pulse input: 0.1Hz~50kHz; range of voltage: 10-30V Digital output Y1 Open collector output Range of voltage: 0~24V Range of current: 0~50mA Y2/DO Open collector out / Pulse out Open collector output: same as Y1 Pulse output: 0~50kHz; Relay output RA/RB/RC Control board relay output RA-RB: NC; RA-RC: NO Contact capacity: 250VAC/3A, 30VDC/3A Terminal 485  Interface 485+ 485 differential signal + Rate: 4800/9600/19200/38400/57600/115200bps 485− 485 differential signal - Maximum distance - 500m (standard network cable used) GND 485 communication shield grounding Isolated from COM interiorly Keypad 485 interface CN4 Keypad 485 interface Maximum communication distance is 15m when connected to Keypad Use standard network cable 5.Environment requirement:→Conditions: Indoors, free from direct sunlight, corrosive gases, flammable gases, oil mist, water vapor, metal particles, etc.→Altitude: 0~2,000m. Derating is required above 1,000m, Rated output current should be derated 1% per 100m increase above 1000m.→Ambient temperature: -10°C~50°C.Derating 1% per centigrade additional for temperature >50°C→Vibration: Less than 5.9 m/s² (0.6g)→Storage temperature: -40~70°C→Protection grade: IP20→Type of cooling: Air cooling6.Applications:Fan, oil pump, water pump, compressor, air compressor, injection molding machine, engraving machine, textile, packaging, conveyor, treadmill, printing machine, lathe, machine tool, hydraulic machine, wire drawing, winder/un-winder, knitting Machine, compressor, extruding machine, injection machine, AC motor, braiding machine, pressure fan, forced draught blower, blower, blowing machine, blow molding machine, root's blower, film blowing machine, cutter bar, cut-off machine, slitter, Cutting machine, grinder, cluster, glazing machine, polisher, polishing machine, laundry-drier, drying machine, ball crusher, ball grinding mill, drawing machine. 7.Key wordsFrequency inverters, AC Drives, variable frequency drives (VFD), AC motor drives, frequency converters, frequency changers, adjustable speed drives (ASD), adjustable frequency drives (AFD), variable speed drives (VSD), AC motor speed controller, AC variable frequency drive, variable frequency inverter, AC motor speed controller, EMI filter, Input EMI Filters, Output EMI Filters, AC Choke, AC Reactor, Input AC Choke, Output AC Choke, Input AC Reactor, Output AC Reactor, DC Choke, DC Reactor, Input DC Choke, Output DC Reactor, Input DC Reactor, Servo Drive, Servo Motor & Drive, Servo Motor & Drive System


Отправить запрос, связаться с поставщиком

Кому: Jiangsu GTAKE Electric Co., Ltd
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

GK600 Series General Purpose Frequency Changer (VFD)GK600 Series General Purpose Frequency Changer (VFD),Website:, adopting advanced sensorless vec...
GK800 Closed-loop Vector Control AC Variable Frequency Drive GK800 Series High Performance AC Variable Frequency Drives,Website:, adopti...
GK1000 AFE Energy Feedback AC Motor DrivesGK1000 provides active front end (Active Front End,Website:, hereinafter referred to as AFE) function.Act...
GK800 Closed-loop Vector Control AC DrivesGK800 Series High Performance AC Drives,Website:, adopting most advanced close-loop vector control techno...
GK800-2T90 Strong Overload Capacity AC Drives,Website:, Vector-controlled AC Motor Drives
Все товары поставщика

Похожие товары

Rated Power 2400W 24VDC Solar Inverter
Rated Power 2400W 24VDC Solar Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24VDC Solar Inverter The DC 2.4 kw inverterwith a rated power of 2400 watts is...
Rated Power 2400W 24VDC PV Inverter
Rated Power 2400W 24VDC PV Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24VDC PV Inverter This is a single phase inverter rated at 2400 watts, 24 volt...
Rated Power 2400W 24VDC Pure Sine Wave Solar Inverter
Rated Power 2400W 24VDC Pure Sine Wave Solar Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24 Volt Pure Sine Wave Inverter It is a new generation of power inverter with ...
Rated Power 2400W 24VDC Off Grid Solar Inverter
Rated Power 2400W 24VDC Off Grid Solar Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24VDC Off Grid Solar Inverter This is a cost-effective solar inverter that acc...
Rated Power 2400W 24VDC Battery Inverter
Rated Power 2400W 24VDC Battery Inverter Продавец: Shenzhen BaoEr Energy Technology Co., LTD. Rated Power 2400W 24VDC Battery Inverter The Rated Power 2400W 24VDC Battery Inverter is a mid-r...