GK600 Sensorless Vector Control Frequency Inverters
GK600 Series General Purpose Frequency Inverter
GK600 Series General Purpose Frequency Inverter,Website:, adopting advanced sensorless vector control technology with robust sensorless vector control, precise sensorless vector control, and different V/f curves programmable, are widely applied to various industrial sectors. GK600 series Frequency Inverter are competitive in market with comprehensive advantages, such as its widely-used characteristics, favorable performance-price ratio, and easier operation and maintenance for users, etc.1.Model Explanation
2.Nameplate Information
3.Information of Product Model3AC 380V/400V/415V/440V/460V/480V -10%~10%, 50Hz/60Hz -5%~5%
Variable Frequency Drive model
Power rating (kW)
Rated output current (A)
Rated input current (A)
Applicable motor (kW)
Brake unit
GK600-4T2.2G/3.7LB
2.2G
2.2
5.5
9.2
2.2
Built-in
3.7L
3.7
9
14.9
3.7
GK600-4T3.7G/5.5LB
3.7G
3.7
9
14.9
3.7
5.5L
5.5
13
21.5
5.5
GK600-4T5.5G/7.5LB
5.5G
5.5
13
21.5
5.5
7.5L
7.5
17
27.9
7.5
GK600-4T7.5G/11LB
7.5G
7.5
17
27.9
7.5
11L
11
24
39
11
GK600-4T11G/15LB
11G
11
24
39
11
15L
15
30
50.3
15
GK600-4T15G/18.5LB
15G
15
30
50.3
15
18.5L
18.5
39
60
18.5
GK600-4T18.5G/22L(B)*
18.5G
18.5
39
60
18.5
Built-in optional
22L
22
45
69.3
22
GK600-4T22G/30L(B)*
22G
22
45
69.3
22
30L
30
60
86
30
GK600-4T30G/37L(B)*
30G
30
60
86
30
37L
37
75
104
37
GK600-4T37G/45L(B)*
37G
37
75
104
37
45L
45
91
124
45
GK600-4T45G/55L(B)*
45G
45
91
124
45
55L
55
112
150
55
GK600-4T55G/75L
55G
55
112
150
55
Externally mounted when needed
75L
75
150
201
75
GK600-4T75G/90L
75G
75
150
201
75
90L
90
176
236
90
GK600-4T90G/110L
90G
90
176
160**
90
Externally mounted when needed
110L
110
210
192**
110
GK600-4T110G/132L
110G
110
210
192**
110
132L
132
253
232**
132
GK600-4T132G/160L
132G
132
253
232**
132
160L
160
310
285**
160
GK600-4T160G/185L
160G
160
310
285**
160
185L
185
350
326**
185
GK600-4T185G/200L
185G
185
350
326**
185
200L
200
380
354**
200
GK600-4T200G/220L
200G
200
380
354**
200
220L
220
430
403**
220
GK600-4T220G/250L
220G
220
430
403**
220
250L
250
470
441**
250
GK600-4T250G/280L
250G
250
470
441**
250
280L
280
520
489**
280
GK600-4T280G/315L
280G
280
520
489**
280
315L
315
590
571**
315
GK600-4T315G/355L
315G
315
590
571**
315
355L
355
650
624**
355
GK600-4T355G/400L
355G
355
650
624**
355
400L
400
725
699**
400
GK600-4T400G/450L
400G
400
725
699**
400
450L
450
820
790**
450
1AC/3AC 208V/220V/230V 50/60Hz -10%~10%, 50Hz/60Hz -5%~5%
Variable Frequency Drive model
Power rating (kW)
Rated output current (A)
Applicable motor (kW)
Brake unit
GK600-2T0.4B
0.4
2.6
0.4
Built-in
GK600-2T0.75B
0.75
4.5
0.75
GK600-2T1.5B
1.5
7.5
1.5
GK600-2T2.2B
2.2
11
2.2
GK600-2T3.7B
3.7
17
3.7
GK600-2T5.5B
5.5
25
5.5
GK600-2T7.5B
7.5
33
7.5
GK600-2T11(B)
11
45
11
Built-in optional
GK600-2T15(B)
15
60
15
GK600-2T18.5(B)
18.5
73
18.5
GK600-2T22(B)
22
96
22
GK600-2T30
30
112
30
Externally mounted when needed
GK600-2T37
37
144
37
GK600-2T45
45
176
45
GK600-2T55
55
210
55
GK600-2T75
75
288
75
GK600-2T90
90
310(350)
90
GK600-2T110
110
415
110
* means brake unit is optional built-in. Take 18.5G/22L for example: the model without brake unit is GK600-4T18.5G/22L, and the model with brake unit is GK600-4T18.5G/22LB. Braking resistor needs to be mounted externally with reference to Table 3-3.** means the rated input current configured a DC reactor. The drive GK600-4T90G/110L or above is provided with an external-mounted DC reactor in shipment as default. Be sure to connect the DC reactor. Failure to comply may result in drive abnormal running.
4.Technical Features of GK600 Frequency Inverter
Table 3 Technical Features of GK600 Frequency Inverter
Power input
Rated input voltage
3-phase AC208V/220V/230V/240V/380V/400V/415V/440V/460V/480V
1-phase AC220V/AC230V/AC240V
Rated input current
See Section 2.3 in the User Manual
Frequency
50Hz/60Hz, tolerance ±5%
Allowable range of voltage
Continuous voltage fluctuation ±10%, short fluctuation -15%~+10%, i.e. 323V~528V;
Voltage out-of-balance rate <3%, distortion rate as per the requirements of IEC61800-2
Power output
Standard applicable motor (kW)
See Section 2.3 in the User Manual
Rated current (A)
See Section 2.3 in the User Manual
Output voltage (V)
3-phase: 0~ rated input voltage, error < ±3%
Output frequency (Hz)
0.00~ 600.00Hz; unit: 0.01Hz
Overload capacity
150% - 1min; 180% - 10s; 200% - 0.5s
Control characteristics
V/f patterns
V/f control
Sensor-less vector control 1
Sensor-less vector control 2
Range of speed regulation
1:100 ( V/f control, sensor-less vector control 1)
1:200 (sensor-less vector control 2)
Speed accuracy
±0.5% (V/f control)
±0.2% (sensor-less vector control 1 & 2)
Speed fluctuation
±0.3% (sensor-less vector control 1 & 2)
Torque response
< 10ms (sensor-less vector control 1 & 2)
Starting torque
0.5Hz: 180% (V/f control, sensor-less vector control 1)
0.25Hz: 180% (sensor-less vector control 2)
Basic functions
Start frequency
0.00~ 600.00Hz
Accel/Decel time
0.00~60000s
Carrier frequency
0.7kHz~16kHz
Frequency setting sources
Digital setting + keypad ∧/∨
Digital setting + terminal UP/DOWN
Communication
Analog setting (AI1/AI2/EAI)
Terminal pulse setting
Motor started methods
Started from starting frequency
DC braking and then started
Speed search started
Motor stopped methods
Ramp to stop
Coast to stop
Ramp stop + DC brake
Basic functions
Dynamic braking capacity
Brake unit action voltage: 650V~750V; service time: 0.0~100.0s; brake units for GK600-4T45G/55L and below are built in or can be built in. See table 2-1
DC braking capacity
DC braking start frequency: 0.00~600.00Hz
DC braking current: 0.0~100.0%
DC braking time: 0.0~30.00s
Input terminals
6 digital inputs, one of which can be used for high-speed pulse input. Compatible with active open collectors NPN, PNP and dry contact input. Digital inputs can be extended to 7
2 analog inputs, one of which is voltage/current programmable, and the other supports voltage only. Analog inputs can be extended to 3, and the extended one is voltage/current programmable
Output terminals
1 high-speed pulse output, 0~50kHz square wave signal output; can output signals such as command frequency, or output frequency, etc.
1 digital output
1 relay output (can be extended to 2)
1 analog output (can be extended to 2), voltage/current output programmable; can output signals such as setting frequency, or output frequency, etc
Featured functions
Parameter copy, parameter backup, common DC bus, free switchover between two motors’ parameters, flexible parameter displayed & hidden, various master & auxiliary command and switchover, speed search started, a variety of Accel/Decel curves optional, automatic correction of analog, contracting brake control, 16-step speed control programmable (2-step speed supports flexible frequency command), wobble frequency control, fixed length control, count function, three faults recorded, over excitation brake, over voltage stall protection, under voltage stall protection, restart upon power loss, skip frequency, frequency binding,four kinds of Accel/Decel time, motor thermal protection, flexible fan control, process PID control, simple PLC, multi-functional key programmable, droop control, parameter identification, field-weakening control, high-precision torque restraint, V/f separated control
Protection functions
Refer to Chapter 7- Troubleshooting in the User Manual
Environment
Place of operation
Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water drop or salt, etc.
Altitude
0~2000m
De-rate 1% for every 100m when the altitude is above 1000 meters
Ambient temperature
-10℃~50℃
Relative humidity
0~95%, no condensation
Vibration
Less than 5.9m/s2 (0.6g)
Storage temperature
-40℃~+70℃
Others
Efficiency at rated Amps
Rated power
7.5kW and below: ≥93%
11~ 45kW: ≥ 95% 5kW and above: ≥98%
Installation
Wall-mounted
IP grade
IP20
Cooling method
Fan cooled
Control Board Diagram
Wiring Diagram
Control Terminal Specification
Control terminal specification
Category
Terminal
Terminal designation
Specification
Analog input
+10V
Analog input reference voltage
10.3V ±3%
Maximum output current 25mA The resistance of external potentiometer should be larger than 400Ω
GND
Analog ground
Isolated from COM interiorly
AI1
Analog input 1
0~20mA: input impedance - 500Ω, maximum input current - 25mA
0~10V: input impedance - 100kΩ, maximum input voltage - 12.5V
Switch S2 on control board for jumping from 0~20mA and 0~10V, factory default: 0~10V
AI2
Analog input 2
-10V~10V: input impedance - 25kΩ
Range: -12.5V~+ 12.5V
Analog output
AO1
Analog output 1
0~20mA: impedance - 200Ω~500Ω
0~10V: impedance ≥ 10k
Switch S3 on control board for jumping between 0~20mA and 0~10V, factory default: 0~10V
GND
Analog ground
Isolated from COM interiorly
Digital input
+24V
+24V
24V±10%, Isolated from GND interiorly
Maximum load - 200mA
PLC
Digital input Common terminal
Used for switching between high and low levels, short-circuited with +24V when delivery, i.e. low value of digital input valid
External power input
COM
+24V ground
Isolated from GND interiorly
X1~X5
Digital input Terminals 1~5
Input: 24VDC, 5mA
Range of frequency: 0~200Hz
Range of voltage: 10V~30V
X6/DI
Digital input/pulse input
Digital input: same as X1~X5
Pulse input: 0.1Hz~50kHz; range of voltage: 10-30V
Digital output
Y1
Open collector output
Range of voltage: 0~24V
Range of current: 0~50mA
Y2/DO
Open collector out / Pulse out
Open collector output: same as Y1
Pulse output: 0~50kHz;
Relay output
RA/RB/RC
Control board relay output
RA-RB: NC; RA-RC: NO
Contact capacity: 250VAC/3A, 30VDC/3A
Terminal 485 Interface
485+
485 differential signal +
Rate: 4800/9600/19200/38400/57600/115200bps
485−
485 differential signal -
Maximum distance - 500m (standard network cable used)
GND
485 communication shield grounding
Isolated from COM interiorly
Keypad 485 interface
CN4
Keypad 485 interface
Maximum communication distance is 15m when connected to Keypad
Use standard network cable
5.Environment requirement:→Conditions: Indoors, free from direct sunlight, corrosive gases, flammable gases, oil mist, water vapor, metal particles, etc.→Altitude: 0~2,000m. Derating is required above 1,000m, Rated output current should be derated 1% per 100m increase above 1000m.→Ambient temperature: -10°C~50°C.Derating 1% per centigrade additional for temperature >50°C→Vibration: Less than 5.9 m/s² (0.6g)→Storage temperature: -40~70°C→Protection grade: IP20→Type of cooling: Air cooling6.Applications:Fan, oil pump, water pump, compressor, air compressor, injection molding machine, engraving machine, textile, packaging, conveyor, treadmill, printing machine, lathe, machine tool, hydraulic machine, wire drawing, winder/un-winder, knitting Machine, compressor, extruding machine, injection machine, AC motor, braiding machine, pressure fan, forced draught blower, blower, blowing machine, blow molding machine, root's blower, film blowing machine, cutter bar, cut-off machine, slitter, Cutting machine, grinder, cluster, glazing machine, polisher, polishing machine, laundry-drier, drying machine, ball crusher, ball grinding mill, drawing machine.
7.Key wordsFrequency inverters, AC Drives, variable frequency drives (VFD), AC motor drives, frequency converters, frequency changers, adjustable speed drives (ASD), adjustable frequency drives (AFD), variable speed drives (VSD), AC motor speed controller, AC variable frequency drive, variable frequency inverter, AC motor speed controller, EMI filter, Input EMI Filters, Output EMI Filters, AC Choke, AC Reactor, Input AC Choke, Output AC Choke, Input AC Reactor, Output AC Reactor, DC Choke, DC Reactor, Input DC Choke, Output DC Reactor, Input DC Reactor, Servo Drive, Servo Motor & Drive, Servo Motor & Drive System
Other supplier products
|
|
GK1000 AFE Energy Feedback AC DrivesGK1000 provides active front end (Active Front End,Website:, hereinafter referred to as AFE) function. Active f... |
|
|
GK600 Series General Purpose Frequency Changer (VFD)GK600 Series General Purpose Frequency Changer (VFD),Website:, adopting advanced sensorless vec... |
|
|
AC Motor Drives For Splitting Machine,Website:, AC Motor Drives For Splitting Machine |
|
|
GK800Z AC Motor Drives for Sync Injection Molding Machine
GTAKE GK800Z Series Electro-hydraulic Servo Drives are dedicated AC Motor Driv... |
|
|
GK600 Series General Purpose Frequency Changer (VFD)GK600 Series General Purpose Frequency Changer (VFD),Website:, adopting advanced sensorless vec... |
供应产品
Same products