UV Aging Test Chamber
Производитель: Тысяча сплошная точный электромеханический прибор контрольно-измерительной ЛТД
Все товары поставщика
Все товары поставщика
The UV aging test chamber is suitable for all kinds of geo-synthetics, such as light resistance, weather resistance and light ageing
The exposure test of the sample was carried out in a fluorescent UV lamp vessel in a controlled environment. It can simulate and strengthen the environmental factors in the natural climate that are affected by light, heat, humidity, and rainfall as the main aging. It can simulate the accelerated test under long term exposure to obtain the results of the weather resistance of the material.
The exposure test of the sample was carried out in a fluorescent UV lamp vessel in a controlled environment. It can simulate and strengthen the environmental factors in the natural climate that are affected by light, heat, humidity, and rainfall as the main aging. It can simulate the accelerated test under long term exposure to obtain the results of the weather resistance of the material.
·JTG E50 T1164The methods of geo-synthetics for highway engineering
·GB/T 14522-93Accelerated weathering test method for plastics, coatings and rubber materials used for machinery industrial products.
·GB-T16422.3-1997Plastics--Methods of exposure to laboratory light sources--Part 3: Fluorescent UV lamps
·ISO4892-3:1994Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
·GB/T 14522-93Accelerated weathering test method for plastics, coatings and rubber materials used for machinery industrial products.
·GB-T16422.3-1997Plastics--Methods of exposure to laboratory light sources--Part 3: Fluorescent UV lamps
·ISO4892-3:1994Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
StandardStructures
· Main features: light, condensation, automatic cycle control, real-time monitoring and display
· Light temperature: RT + 10 ℃ ~ 70 ℃
· Condensation temperature: 50 ℃
· Condensation method: steam humidification condensation
· Temperature uniformity: ± 3 ℃
· Irradiation intensity: 0.55W / m2
· Light / condensation cycle: 0 ~ 9999h,59min. It can be set (such as: 4H / 4H or 8H / 8H)
· Lamp center distance: 70mm
· Sample and lamp plane distance: 55mm
· Light temperature: RT + 10 ℃ ~ 70 ℃
· Condensation temperature: 50 ℃
· Condensation method: steam humidification condensation
· Temperature uniformity: ± 3 ℃
· Irradiation intensity: 0.55W / m2
· Light / condensation cycle: 0 ~ 9999h,59min. It can be set (such as: 4H / 4H or 8H / 8H)
· Lamp center distance: 70mm
· Sample and lamp plane distance: 55mm
· UV lamp: UV-A340 or UV-B313 (optional)
· UV wavelength: (UVA) 315 ~ 400nm; (UVB) 280 ~ 315nm
· Lamp life: 1600 ~ 1800H
· Standard test piece: 75 × 150mm or customized according to customer requirements (it can be made for 21 samples)
· Control system: touch screen controller, real-time monitoring friendly interface, easy to use and easy to operate.
· Power supply: AC220V 50HZ 4.7KW
· The structure of the test chamber is made of corrosion-resistant metal material, including 8 fluorescent UV lamp, water tray, test sample rack and touch screen controller.
· Lamp power is 40W and lamp length is 1200 mm. The working area of the test chamber is in the range of 900 × 210 mm.
· The lamp is installed in a row of four rows, installed in two rows, and the lamp is arranged in parallel, and the center distance of the lamp is 70 mm.
· The test sample is fixedly mounted at a distance of 50 mm from the nearest parallel surface of the lamp surface. The test specimen and its support form the inner wall of the box, and their backs are exposed to room temperature cooling air due to the temperature difference between the test sample and the air in the box. So that the test sample surface condensation phase to produce a stable condensation conditions, the test chamber shall be of natural air convection from the bottom of the box through the outer wall of the box and the test sample.
· The water vapor is produced by the low water pan of the heating box. The water depth is not more than 25mm, and the water supply automatic control. The water dish should be cleaned regularly to prevent the formation of scale.
· The temperature of the test chamber is measured by a sensor with a width of 75 mm, height of 100 mm and a thickness of 2.5 mm on a black aluminum plate (blackboard). The blackboard shall be placed in the central area of the exposure test. The measuring range of the thermometer shall be 30 to 80 ° C , The tolerance is ± 1 ° C. Control of the lighting and condensation stages should be carried out separately, and the condensation stage is controlled by the heated water temperature.
· Standard configuration: (1) 12 UV lamp; (2) 21 sets of sample rack
· UV wavelength: (UVA) 315 ~ 400nm; (UVB) 280 ~ 315nm
· Lamp life: 1600 ~ 1800H
· Standard test piece: 75 × 150mm or customized according to customer requirements (it can be made for 21 samples)
· Control system: touch screen controller, real-time monitoring friendly interface, easy to use and easy to operate.
· Power supply: AC220V 50HZ 4.7KW
Technical Parameters
Features
Stable reliable and consistent
· The structure of the test chamber is made of corrosion-resistant metal material, including 8 fluorescent UV lamp, water tray, test sample rack and touch screen controller.
· Lamp power is 40W and lamp length is 1200 mm. The working area of the test chamber is in the range of 900 × 210 mm.
· The lamp is installed in a row of four rows, installed in two rows, and the lamp is arranged in parallel, and the center distance of the lamp is 70 mm.
· The test sample is fixedly mounted at a distance of 50 mm from the nearest parallel surface of the lamp surface. The test specimen and its support form the inner wall of the box, and their backs are exposed to room temperature cooling air due to the temperature difference between the test sample and the air in the box. So that the test sample surface condensation phase to produce a stable condensation conditions, the test chamber shall be of natural air convection from the bottom of the box through the outer wall of the box and the test sample.
· The water vapor is produced by the low water pan of the heating box. The water depth is not more than 25mm, and the water supply automatic control. The water dish should be cleaned regularly to prevent the formation of scale.
· The temperature of the test chamber is measured by a sensor with a width of 75 mm, height of 100 mm and a thickness of 2.5 mm on a black aluminum plate (blackboard). The blackboard shall be placed in the central area of the exposure test. The measuring range of the thermometer shall be 30 to 80 ° C , The tolerance is ± 1 ° C. Control of the lighting and condensation stages should be carried out separately, and the condensation stage is controlled by the heated water temperature.
· Standard configuration: (1) 12 UV lamp; (2) 21 sets of sample rack
◆ Inner box size: D450 ×W1165×H500 mm
◆ Outline dimension: D500×W1300×H1400 mm
◆ Liner material: SUS304# stainless steel plate
◆ Shell material: SUS304 # senior stainless steel plate
◆ Test piece fixture material: SUS304 stainless steel plate
◆ Imported lamp: Two rows of eight pieces, 40W / pieces
◆ Water and consumption: Clean water or distilled water 8 liters / day
◆ Control system: Color touch screen, real-time display irradiation, condensation, radiation intensity, lamp life tired. Chinese input mode, the whole automatic operation.
◆ Liner material: SUS304# stainless steel plate
◆ Shell material: SUS304 # senior stainless steel plate
◆ Test piece fixture material: SUS304 stainless steel plate
◆ Imported lamp: Two rows of eight pieces, 40W / pieces
◆ Water and consumption: Clean water or distilled water 8 liters / day
◆ Control system: Color touch screen, real-time display irradiation, condensation, radiation intensity, lamp life tired. Chinese input mode, the whole automatic operation.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
Fiber fineness analyzer | Mainly used for the determination of wool, rabbit hair and other animal fiber diameter and other natural, artificial mixed, blended product fiber c... | |
IEC60695 Needle Flame Tester | Standards:GB / T 4207-84, IEC 6112, ASTM D3638, DIN 53480 and UL 746A test methodsScope of application:Needle flame tester used not only for low-vo... | |
shoe bending durability tester | Standards: Satra TM92 & 77 The Footwear Flection Tester is supplied in both single or twin station models and the operation simulates t... | |
Тестер бактериальной эффективности ASTM F2101 (BFE) | Эффективность бактериальной фильтрации для лицевых масок Тестер BFE предназначен для определения эффективности бактериальной фильтрации (BFE) медиц... | |
Pneumatic fabric stiffness tester | The bending performance of the fabric is an important physical parameter that we study the properties of fabric, such as crisp, drape, and softness... |
Похожие товары
FILTER ELEMENT FBX-630x10 for Pacitcan TPP material | Продавец: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD | FILTER ELEMENT FBX-630x10 for Pacitcan TPP material The use of advanced technology, absolutely fi... | |
Интеллектуальная прецизионная паяльная станция Aixun T320 с ручкой T245/210 | Продавец: ШЭНЬЧЖЭНЬСКАЯ ТЕХНОЛОГИЯ PHONEFIX, LTD (КИТАЙСКИЙ PHONEFIX) | Описание JCID Aixun T320 Интеллектуальная интегрированная прецизионная паяльная станция с ручкой ... | |
Micro Smart Electric Robot Roller DC Brushed Motor | Продавец: Zhoushan Yehao Electrical Appliance Co., Ltd | YH-(DC-42) Roller Brush Motor, dia 44mm, height 94mm,16000rpm/min, rated input voltage 6-15V, Rat... | |
Газификационная печь | Продавец: Jinan Baoying Machinery Technology Co., Ltd | Стоимость установки котлов с твердыми частицами биомассы очень низка, в отоплении очень безопасна... | |
JTX Nano Conductive Silver Paste For Phone Screen Line Circuit Repair | Продавец: Phonefix | JTX Nano Conductive Silver Paste repairs iPhone screen/green screen/white screen lines issues cau... |