UV Aging Test Chamber
The UV aging test chamber is suitable for all kinds of geo-synthetics, such as light resistance, weather resistance and light ageing
The exposure test of the sample was carried out in a fluorescent UV lamp vessel in a controlled environment. It can simulate and strengthen the environmental factors in the natural climate that are affected by light, heat, humidity, and rainfall as the main aging. It can simulate the accelerated test under long term exposure to obtain the results of the weather resistance of the material.
The exposure test of the sample was carried out in a fluorescent UV lamp vessel in a controlled environment. It can simulate and strengthen the environmental factors in the natural climate that are affected by light, heat, humidity, and rainfall as the main aging. It can simulate the accelerated test under long term exposure to obtain the results of the weather resistance of the material.
·JTG E50 T1164The methods of geo-synthetics for highway engineering
·GB/T 14522-93Accelerated weathering test method for plastics, coatings and rubber materials used for machinery industrial products.
·GB-T16422.3-1997Plastics--Methods of exposure to laboratory light sources--Part 3: Fluorescent UV lamps
·ISO4892-3:1994Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
·GB/T 14522-93Accelerated weathering test method for plastics, coatings and rubber materials used for machinery industrial products.
·GB-T16422.3-1997Plastics--Methods of exposure to laboratory light sources--Part 3: Fluorescent UV lamps
·ISO4892-3:1994Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
StandardStructures
· Main features: light, condensation, automatic cycle control, real-time monitoring and display
· Light temperature: RT + 10 ℃ ~ 70 ℃
· Condensation temperature: 50 ℃
· Condensation method: steam humidification condensation
· Temperature uniformity: ± 3 ℃
· Irradiation intensity: 0.55W / m2
· Light / condensation cycle: 0 ~ 9999h,59min. It can be set (such as: 4H / 4H or 8H / 8H)
· Lamp center distance: 70mm
· Sample and lamp plane distance: 55mm
· Light temperature: RT + 10 ℃ ~ 70 ℃
· Condensation temperature: 50 ℃
· Condensation method: steam humidification condensation
· Temperature uniformity: ± 3 ℃
· Irradiation intensity: 0.55W / m2
· Light / condensation cycle: 0 ~ 9999h,59min. It can be set (such as: 4H / 4H or 8H / 8H)
· Lamp center distance: 70mm
· Sample and lamp plane distance: 55mm
· UV lamp: UV-A340 or UV-B313 (optional)
· UV wavelength: (UVA) 315 ~ 400nm; (UVB) 280 ~ 315nm
· Lamp life: 1600 ~ 1800H
· Standard test piece: 75 × 150mm or customized according to customer requirements (it can be made for 21 samples)
· Control system: touch screen controller, real-time monitoring friendly interface, easy to use and easy to operate.
· Power supply: AC220V 50HZ 4.7KW
· The structure of the test chamber is made of corrosion-resistant metal material, including 8 fluorescent UV lamp, water tray, test sample rack and touch screen controller.
· Lamp power is 40W and lamp length is 1200 mm. The working area of the test chamber is in the range of 900 × 210 mm.
· The lamp is installed in a row of four rows, installed in two rows, and the lamp is arranged in parallel, and the center distance of the lamp is 70 mm.
· The test sample is fixedly mounted at a distance of 50 mm from the nearest parallel surface of the lamp surface. The test specimen and its support form the inner wall of the box, and their backs are exposed to room temperature cooling air due to the temperature difference between the test sample and the air in the box. So that the test sample surface condensation phase to produce a stable condensation conditions, the test chamber shall be of natural air convection from the bottom of the box through the outer wall of the box and the test sample.
· The water vapor is produced by the low water pan of the heating box. The water depth is not more than 25mm, and the water supply automatic control. The water dish should be cleaned regularly to prevent the formation of scale.
· The temperature of the test chamber is measured by a sensor with a width of 75 mm, height of 100 mm and a thickness of 2.5 mm on a black aluminum plate (blackboard). The blackboard shall be placed in the central area of the exposure test. The measuring range of the thermometer shall be 30 to 80 ° C , The tolerance is ± 1 ° C. Control of the lighting and condensation stages should be carried out separately, and the condensation stage is controlled by the heated water temperature.
· Standard configuration: (1) 12 UV lamp; (2) 21 sets of sample rack
· UV wavelength: (UVA) 315 ~ 400nm; (UVB) 280 ~ 315nm
· Lamp life: 1600 ~ 1800H
· Standard test piece: 75 × 150mm or customized according to customer requirements (it can be made for 21 samples)
· Control system: touch screen controller, real-time monitoring friendly interface, easy to use and easy to operate.
· Power supply: AC220V 50HZ 4.7KW
Technical Parameters
Features
Stable reliable and consistent
· The structure of the test chamber is made of corrosion-resistant metal material, including 8 fluorescent UV lamp, water tray, test sample rack and touch screen controller.
· Lamp power is 40W and lamp length is 1200 mm. The working area of the test chamber is in the range of 900 × 210 mm.
· The lamp is installed in a row of four rows, installed in two rows, and the lamp is arranged in parallel, and the center distance of the lamp is 70 mm.
· The test sample is fixedly mounted at a distance of 50 mm from the nearest parallel surface of the lamp surface. The test specimen and its support form the inner wall of the box, and their backs are exposed to room temperature cooling air due to the temperature difference between the test sample and the air in the box. So that the test sample surface condensation phase to produce a stable condensation conditions, the test chamber shall be of natural air convection from the bottom of the box through the outer wall of the box and the test sample.
· The water vapor is produced by the low water pan of the heating box. The water depth is not more than 25mm, and the water supply automatic control. The water dish should be cleaned regularly to prevent the formation of scale.
· The temperature of the test chamber is measured by a sensor with a width of 75 mm, height of 100 mm and a thickness of 2.5 mm on a black aluminum plate (blackboard). The blackboard shall be placed in the central area of the exposure test. The measuring range of the thermometer shall be 30 to 80 ° C , The tolerance is ± 1 ° C. Control of the lighting and condensation stages should be carried out separately, and the condensation stage is controlled by the heated water temperature.
· Standard configuration: (1) 12 UV lamp; (2) 21 sets of sample rack
◆ Inner box size: D450 ×W1165×H500 mm
◆ Outline dimension: D500×W1300×H1400 mm
◆ Liner material: SUS304# stainless steel plate
◆ Shell material: SUS304 # senior stainless steel plate
◆ Test piece fixture material: SUS304 stainless steel plate
◆ Imported lamp: Two rows of eight pieces, 40W / pieces
◆ Water and consumption: Clean water or distilled water 8 liters / day
◆ Control system: Color touch screen, real-time display irradiation, condensation, radiation intensity, lamp life tired. Chinese input mode, the whole automatic operation.
◆ Liner material: SUS304# stainless steel plate
◆ Shell material: SUS304 # senior stainless steel plate
◆ Test piece fixture material: SUS304 stainless steel plate
◆ Imported lamp: Two rows of eight pieces, 40W / pieces
◆ Water and consumption: Clean water or distilled water 8 liters / day
◆ Control system: Color touch screen, real-time display irradiation, condensation, radiation intensity, lamp life tired. Chinese input mode, the whole automatic operation.
在线联系供应商
Other supplier products
Chrysler Bending Test instruments | Brief IntroductionChrysler bending tester is designed for bending and folding manner by testing base fabric adhesion of the coating material,ie mec... | |
Limiting Oxygen Index Chamber | The Limiting Oxygen Index (LOI) fire test is perhaps the most economical and precise quality control test for combustible materials. Its ease of us... | |
Medical Face Mask flammability Test machine | This Medical Face Mask flammability Tester is mainly used to test the flame retardant performance of medical masks. The combustion performance of t... | |
Fabric light transmittance test machine | Light transmittance test machine for fabric is used to determine the total visible light transmittance of the fabric to evaluate the shading proper... | |
Digital Elmendorf Tearing Tester |
Same products
FILTER ELEMENT FBX-630x10 for Pacitcan TPP material | 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD | FILTER ELEMENT FBX-630x10 for Pacitcan TPP material The use of advanced technology, absolutely fi... | |
Aixun T320 智能精密焊台,带 T245/210 手柄 | 卖方: 深圳市维客修科技有限公司 | 描述 JCID Aixun T320 智能集成精密焊台,带 T245 T210 手柄 C210 C245 烙铁头,适用于手机平板电脑电子 BGA 主板 SMD 芯片焊接维修。JC-... | |
Micro Smart Electric Robot Roller DC Brushed Motor | 卖方: Zhoushan Yehao Electrical Appliance Co., Ltd | YH-(DC-42) Roller Brush Motor, dia 44mm, height 94mm,16000rpm/min, rated input voltage 6-15V, Rat... | |
气化燃烧喷火炉 | 卖方: 济南宝莹机械科技有限公司 | 生物质颗粒锅炉的安装成本很低廉,在供暖的时候很安全:而且设备可以通用,在不改变原来的取暖设备的情况下,暖气片和管道可以通用,在利用水循环来达到供暖原材料的来源就很广泛,而且永不枯竭,随处可取(如... | |
JTX Nano Conductive Silver Paste For Phone Screen Line Circuit Repair | 卖方: Phonefix | JTX Nano Conductive Silver Paste repairs iPhone screen/green screen/white screen lines issues cau... |