Real-Time Gas Composition Analyzer for Battery Safety Testing
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system is compliant with the following standard:
UL 9540A-2025 – Standard for Testing Thermal Runaway Fire Propagation in Battery Energy Storage Systems
Parameters
| Item | Specification |
|---|---|
| Platform Dimensions | Determined by sample volume requirements |
| Control Cabinet | 650(L) × 675(W) × 1750(H) mm |
| Fourier Transform Infrared (FTIR) System | 650(W) × 675(D) × 1750(H) mm |
| Power Supply | AC 220 V, 30 A |
| Weight | Approximately 900 kg |
| Backup Gas Source | Nitrogen ≥ 99.99% |
Features
High-Strength Stainless Steel Vessel
304 stainless steel chamber ensures corrosion resistance, high-temperature durability, and mechanical integrity. Design pressure 3 MPa, constant operating pressure 2.5 MPa, with a safety valve for rapid pressure relief.
Multi-Channel Battery Parameter Monitoring
Supports online monitoring of voltage, temperature, and pressure through K-type high-temperature thermocouples and high-precision imported sensors, covering heating, overcharge, and nail penetration trigger modes.
Integrated Environmental Control
Vacuum extraction, nitrogen filling, exhaust, and oxygen concentration detection (0–100% Vol.) are included. Video monitoring allows real-time observation of thermal runaway events.
Automated Gas Sampling System
Multi-layer sample lines with real-time pressure monitoring ensure continuous, accurate gas sampling. Automatic switching prevents blockage and maintains system integrity.
Heated Sampling Lines
Prevents intrusion of liquid electrolyte into analytical instruments, reducing interference and improving gas composition measurement accuracy.
Advanced Gas Analysis
FTIR spectrometer and electrochemical sensors, combined with a professional analysis model, enable precise online measurement of complex gases produced during battery thermal runaway.
User-Friendly Control Software
Intuitive interface, low latency, real-time monitoring of gas composition, battery parameters, and environmental conditions.
Extended Data Processing
Automatic calculation modules for gas evolution rate and total gas volume, with seamless integration into the software for data visualization and reporting.
Accessories
(1) Multi-layer gas sampling lines
(2) Pressure and temperature sensors
(3) Vacuum pump and nitrogen supply interface
(4) FTIR spectrometer
(5) Electrochemical gas sensors
(6) Heated pipeline assembly
(7) Video monitoring system
(8) Control cabinet with PLC and touchscreen
Test Procedures
Sample Installation: Place battery cells into the pressure vessel and secure the chamber.
System Setup: Connect nitrogen supply and configure oxygen concentration requirements.
Parameter Configuration: Set monitoring channels for voltage, temperature, pressure, and gas analysis in the control software.
Initiate Thermal Runaway: Trigger the battery using heating, overcharge, or nail penetration methods.
Data Acquisition: Real-time monitoring of gas composition, internal pressure, temperature, and battery parameters. Automated calculation of gas evolution rate and total gas volume.
Observation and Recording: Monitor test via video feed and software interface.
Test Completion: Safely vent the vessel, retrieve battery cells, and store collected data for analysis and reporting.
Maintenance Information
Inspect vessel seals, flanges, and sampling connections regularly for integrity.
Calibrate temperature, pressure, and gas sensors periodically.
Clean sampling lines and FTIR components to prevent contamination and measurement errors.
Verify nitrogen supply, vacuum pump operation, and safety valve function before each test.
Backup all acquired test data and system logs for traceability and reporting purposes.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| High-efficiency filter scanning test bench | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and complies with the following standards: (1) GB/T 14295-2... | |
| Resistance to flame propagation tester,ECE R118 Annex 10 | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction This equipment is designed and manufactured according to ECE R118 Annex 10. T... | |
| Bundle wire and cable burning test machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards According to IEC60332-3-10:2000.and GA306.1-2007 Main components Testing cha... | |
| Automatic Scratch Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automatic Scratch Tester is designed for evaluating the hardness and friction performan... | |
| Laboratory Filter Media Performance Testing Device Without Vertical Duct | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The G508 test bench supports parameterized test conditions in accordance with th... |
Похожие товары
| Gasket for Plate Heat Exchanger | Продавец: Hengshui Hongcan Import and Export Trading Co., Ltd | The sealing gasketin plate heat exchangers primarily serves to seal between hot and cold media. ... | |
| Energy Saver | Продавец: O&K GROUP LIMITED | Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies... | |
| ER1100 Aluminum Welding Wire | Продавец: 868776 | The ER1100 Aluminum Welding Wire from Hangzhou Kunli Welding Materials Co., Ltd. is designed for ... | |
| air conditioner | Продавец: O&K GROUP LIMITED | Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies... | |
| MMA-120 Handheld Arc Welder | Продавец: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... |