Real-Time Gas Composition Analyzer for Battery Safety Testing
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system is compliant with the following standard:
UL 9540A-2025 – Standard for Testing Thermal Runaway Fire Propagation in Battery Energy Storage Systems
Parameters
| Item | Specification |
|---|---|
| Platform Dimensions | Determined by sample volume requirements |
| Control Cabinet | 650(L) × 675(W) × 1750(H) mm |
| Fourier Transform Infrared (FTIR) System | 650(W) × 675(D) × 1750(H) mm |
| Power Supply | AC 220 V, 30 A |
| Weight | Approximately 900 kg |
| Backup Gas Source | Nitrogen ≥ 99.99% |
Features
High-Strength Stainless Steel Vessel
304 stainless steel chamber ensures corrosion resistance, high-temperature durability, and mechanical integrity. Design pressure 3 MPa, constant operating pressure 2.5 MPa, with a safety valve for rapid pressure relief.
Multi-Channel Battery Parameter Monitoring
Supports online monitoring of voltage, temperature, and pressure through K-type high-temperature thermocouples and high-precision imported sensors, covering heating, overcharge, and nail penetration trigger modes.
Integrated Environmental Control
Vacuum extraction, nitrogen filling, exhaust, and oxygen concentration detection (0–100% Vol.) are included. Video monitoring allows real-time observation of thermal runaway events.
Automated Gas Sampling System
Multi-layer sample lines with real-time pressure monitoring ensure continuous, accurate gas sampling. Automatic switching prevents blockage and maintains system integrity.
Heated Sampling Lines
Prevents intrusion of liquid electrolyte into analytical instruments, reducing interference and improving gas composition measurement accuracy.
Advanced Gas Analysis
FTIR spectrometer and electrochemical sensors, combined with a professional analysis model, enable precise online measurement of complex gases produced during battery thermal runaway.
User-Friendly Control Software
Intuitive interface, low latency, real-time monitoring of gas composition, battery parameters, and environmental conditions.
Extended Data Processing
Automatic calculation modules for gas evolution rate and total gas volume, with seamless integration into the software for data visualization and reporting.
Accessories
(1) Multi-layer gas sampling lines
(2) Pressure and temperature sensors
(3) Vacuum pump and nitrogen supply interface
(4) FTIR spectrometer
(5) Electrochemical gas sensors
(6) Heated pipeline assembly
(7) Video monitoring system
(8) Control cabinet with PLC and touchscreen
Test Procedures
Sample Installation: Place battery cells into the pressure vessel and secure the chamber.
System Setup: Connect nitrogen supply and configure oxygen concentration requirements.
Parameter Configuration: Set monitoring channels for voltage, temperature, pressure, and gas analysis in the control software.
Initiate Thermal Runaway: Trigger the battery using heating, overcharge, or nail penetration methods.
Data Acquisition: Real-time monitoring of gas composition, internal pressure, temperature, and battery parameters. Automated calculation of gas evolution rate and total gas volume.
Observation and Recording: Monitor test via video feed and software interface.
Test Completion: Safely vent the vessel, retrieve battery cells, and store collected data for analysis and reporting.
Maintenance Information
Inspect vessel seals, flanges, and sampling connections regularly for integrity.
Calibrate temperature, pressure, and gas sensors periodically.
Clean sampling lines and FTIR components to prevent contamination and measurement errors.
Verify nitrogen supply, vacuum pump operation, and safety valve function before each test.
Backup all acquired test data and system logs for traceability and reporting purposes.
在线联系供应商
Other supplier products
| Safety Helmet Impact Acceleration Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Purpose This instrument is suitable for impact - collision tests of helmets. It is a testi... | |
| Automatic Reaction Calorimeter | Standards GB 51283 GB/T 22232 GB/T 17802 SN/T 3078.1 Product Features 1. It offers three calorimetry methods: heat - flow, power - compensati... | |
| Medical Face Mask Synthetic Blood Penetration Test machine | Applicable Standards: GB 19083-2010 YY/T 0691-2008 YY 0469-2011 ISO 22609 ASTM F1862-07 Features: 1. Mask fixture is metal human head mold, ... | |
| Xenon Fastness Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits 1. Adopts high-intensity xenon lamps with a spectral range of 300-... | |
| Laboratory PVT coolant pulse testing equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The PVT Coolant Pulse Test Machine complies with a broad range of international ... |
Same products
| ISO 29463 HEPA/ULPA filter performance testing System | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli... | |
| High-Precision ISO 16890 Filter Media Test Rig for R&D and QC | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com... | |
| Mobile Floor Scrubber Aging Life Tester IEC 60312 | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheMobile Floor Scrubber Aging L... | |
| ISO 12103 Cleanable Filter Media Test System | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| Robotic Vacuum Cleaners Edge-Following Tester | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheEdge-Following Test Equipment... |