ISO 11155 Compliant Cabin Filter Test System
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Test System for both particle separation and gas absorption/desorption of of air filters for passenger compartments (DIN 71460-1/2. ISO 11155-1/2). It povides a maximum of paramater testing for cabin air filters.
Applications
Fractional efficiency according to ISO 11155-1 (DIN 71460-1)
Gas adsorption tests according to ISO 11155-2 (DIN 71460-2)
Adsorption/desorption tests
Research and development tasks on automotive cabin air filters
Standards
GB/T 32085.1 — Automotive Air Conditioning Filters, Part 1: Dust Filtration Test
GB/T 32085.2 — Automotive Air Conditioning Filters, Part 2: Gas Filtration Test
DIN 71460-1 — Road Vehicles, Cabin Air Filters, Part 1: Particulate Filter Test
DIN 71460-2 — Road Vehicles, Cabin Air Filters, Part 2: Gas Filter Test
ISO/TS 11155-1 — Road Vehicles, In-Cabin Air Filters, Part 1: Dust Filtration Test
ISO 11155-2 — Road Vehicles, In-Cabin Air Filters, Part 2
ISO 10121-1 / ISO 10121-2 — General Methods for Air Filter Performance Testing
Principle of Operation
Defined airflow passes through the HEPA inlet filter and the test duct.
The test filter is installed in the adapter, ensuring easy insertion and observation.
Particle aerosols and specific gases are injected upstream of the filter.
Downstream, laser aerosol analyzers and gas analyzers measure particle concentrations and gas composition.
The system calculates fractional efficiency, dust loading, and adsorption/desorption curves.
The exhaust system ensures stable gas conditions and safe operation during filter replacement.
Software allows automated, repeatable testing and data recording/analysis.
Technical Data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | m³/h | 70 … 700 |
| Test aerosol | – | DEHS, DOP, PAO, KCl, NaCl, etc. |
| Test gases | – | n-Butane 80 ppm, Toluene 80 ppm, Sulfur dioxide 30 ppm, Hydrogen sulfide 10 ppm |
| Measuring range, differential pressure | Pa | 0 … 1000 (± 2 %) |
| Test specimen dimensions | mm | max. 600 × 300 |
| Operating medium (gas/air) | – | Room air at standard test conditions (23°C ± 2 K; 50 % ± 2 % RH) |
| Power supply | – | 400 VAC / 3P / 75 A / 50 … 60 Hz and 3 × 230 VAC / 2P / 16 A / 60 Hz |
| Aerosol generation technology | – | Dust disperser SAG 410/L, Atomizer ATM 220. etc. |
| Aerosol conditioning technology | – | Electrostatic Aerosol Neutralizer EAN 581 |
| Aerosol measurement instruments | – | Aerosol spectrometer LAP 322 |
| Gas analysers | – | FID, NDIR |
| Sensors (others) | – | Temperature, relative humidity, absolute pressure |
| System dimensions (W × H × D) | mm | 3700 × 3000 × 3700 |
Features
standard compliant testing of filter media and filter elements
combined testing with particles and with gases
very flexible system configuration possible
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Automotive Seat, Mounting Device and Seat Belt System Testing Machine,Vehicle seat static load testing rig | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automotive Seat, Mounting Device and Seat Belt System Testing Machine is designed to ev... | |
| Computer-controlled Explosion-proof Capillary Rheometer | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Computer-controlled Explosion-proof Capillary Rheometer is a laboratory rheological tes... | |
| ISO/DIS 29461 Turbine Filter Test System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Testing of gas turbine intake filter systems according to ISO 29461-2 and ISO... | |
| IEC Standard Refrigerated Display Cabinet Door Tester Factory Price | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) ISO 15502 Household refrigerating appliances – Character... | |
| Fabric Snagging Performance Testing Machine for Apparel Quality Control | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The ICI Mace Snag Tester is a laboratory device used to evaluate the tendency... |