Wire and Cable Smoke Density Tester Manufacturer | IEC 61034 Cable Smoke Density Test Chamber Supplier

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Features

The enclosure consists of a cubic shell with dimensions of 3000mm ± 30mm (length, width, and height). The internal material of the enclosure is SUS 304 stainless steel, filled with calcium silicate fireproof material, and the exterior is made of iron with powder coating;

All internal fixtures are made of stainless steel; aesthetically pleasing and corrosion-resistant;

The total area of the ventilation holes is 50cm² ± 10cm², and they remain open throughout the test; the baffle height is 1000mm;

Equipped with wire and cable test racks and weights as required by the standard.

The test chamber door has glass observation windows on opposite sides, fitted with sealed transparent windows (minimum 100mm x 100mm) that allow light from the horizontal optical measurement system to pass through. These windows are located 2150mm ± 100mm above the ground;

The photocell and light source are positioned at the center of the windows on each of the two walls, without physical contact.

Parameters

Technical ParameterDetails
Operating Voltage AC 220 V ± 10%, 50HZ
Light Source Voltage DC 12V
Power 2000W
Ambient Temperature 25℃ ± 5℃
Nominal Luminous Flux 2000lm ~ 3000lm
Nominal Color Temperature 2800K ~ 3200K
Air Flow Rate ≥ 2L/min
Fire Supply Time Standard time 40min (settable)
Timing Accuracy ≤ 0.5s for 40min
Calibration Value 100% (transmittance)

Test Procedures

Sample Preparation: Cut a cable or optical fiber sample of the specified length (e.g., ≥1 meter) according to the standard, and condition it at 23℃±5℃ for at least 16 hours.

Equipment Calibration: Calibrate the optical system using filters with different transmittances (e.g., 100%, 75%, 25%) to ensure data accuracy.

Sample Installation: Secure the sample horizontally on the support inside the combustion chamber, adjusting its position so that the distance between the lower surface of the sample and the bottom of the alcohol tray is 150mm±5mm.

Environmental Setup: Measure the temperature inside the combustion chamber door at a height of 1.5m-2.0m from the ground and at least 0.2m from the wall to ensure it is within the range of 25℃±5℃; if necessary, preheat the combustion chamber with a blank test.

Test Start: Ignite the alcohol tray fire source, close the combustion chamber door, and start the fan to ensure even distribution of smoke; the test ends when the fire source is extinguished after 5 minutes or after 40 minutes of testing, whichever comes first, or when the transmittance no longer decreases.

Record Results: Read and record the minimum transmittance (Tmin) during the test, and calculate parameters such as specific optical density (Ds).

Equipment Cleaning: After the test, clean the combustion residue and keep the chamber clean.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Surface Flame Spread Test Apparatus,ASTM E162 Flame propagation test apparatus
Surface Flame Spread Test Apparatus,ASTM E162 Flame propagation test apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com The Surface Flame Spread Test Apparatus is a high-precision instrument designed for evaluat...
Safety Footwear Compression Puncture Tester
Safety Footwear Compression Puncture Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Test purpose Measure the compression resistance of the shoe head cover and the puncture re...
Advanced Tribology Stick Slip Testing System for Automotive & Engineering Materials | Factory Direct China
Advanced Tribology Stick Slip Testing System for Automotive & Engineering Materials | Factory Direct China Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features (1) High-precision measurement: combination of linear motor and for...
Wet Microbial Penetration Tester
Wet Microbial Penetration Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The wet microbial penetration tester is mainly used to evaluate the barrier ability of medi...
Fiber Oil Extractor | ASTM D5842 Wool and Cotton Oil Testing Machine Manufacturer
Fiber Oil Extractor | ASTM D5842 Wool and Cotton Oil Testing Machine Manufacturer Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features (1) Multi-unit design allows 1. 2. or 3 extraction units for simult...
Все товары поставщика

Похожие товары

Gasket for Plate Heat Exchanger
Gasket for Plate Heat Exchanger Продавец: Hengshui Hongcan Import and Export Trading Co., Ltd The sealing gasketin plate heat exchangers primarily serves to seal between hot and cold media. ...
Energy Saver
Energy Saver Продавец: O&K GROUP LIMITED Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies...
ER1100 Aluminum Welding Wire
ER1100 Aluminum Welding Wire Продавец: 868776 The ER1100 Aluminum Welding Wire from Hangzhou Kunli Welding Materials Co., Ltd. is designed for ...
air conditioner
air conditioner Продавец: O&K GROUP LIMITED Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies...
MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Продавец: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...