Thrombite™ Clot Retriever Device

OVERVIEW

Thrombite™ Clot Removal Device

HELICAL OPEN-SIDE STRUCTURE

HIGHER ACUTE RECANALIZATION RATE

The Thrombite™ Mechanical Clot RetrievalDevice, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.

PRODUCT FEATURES

HELICAL OPEN-SIDE STRUCTURE

enables Thrombite™ retriever to efficiently entwine and clamp the clot

assures clot retention for confident removal and revascularization

OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE

increases contact surface with thrombus and maximizes clot integration

EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION

optimizes clot retention during smooth navigation through the tortuous anatomies

PRODUCT FEATURES

Radiopaque markers on the distal end of the device increase device visibility

3 markers for the sizes with 3.0 and 4.0mm diameter

4 markers for the sizes with 5.0 and 6.0mm diameter

Advanced stent surface treatment process

RADIAL FORCE

High radial force is designed for clot integration at the initial stage of stent expansion

Low radial force at nominal stent diameter ensures atraumatic retrieval

RADIAL FORCE

How a Stent Retriever ProcedureIs Performed

Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body.

ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE

STENT RETRIEVAL DEVICE STRUCTURE

Thrombite™

Product code

Diameter D(mm)

Recommended Vessel Diameter(mm)Min. Max.

Recommende Microcatheter ID (inch)

Working Length A(mm)

Stent Length B(mm)

System Length(mm)

3MM

CRD-3-15

3

15

27

1900

CRD-3-20

3

20

32

1900

CRD-3-25

3

25

37

1900

CRD-3-30

3

30

42

1900

4MM

CRD-4-15

4

15

27

1900

CRD-4-20

4

20

32

1900

CRD-4-25

4

25

37

1900

CRD-4-30

4

30

42

1900

5MM

CRD-5-15

5

15

27

1900

CRD-5-20

5

20

32

1900

CRD-5-25

5

25

37

1900

CRD-5-30

5

30

42

1900

6MM

CRD-6-15

6

15

27

1900

CRD-6-20

6

20

32

1900

CRD-6-25

6

25

37

1900

CRD-6-30

6

30

42

1900

INDICATIONS

Thrombite™ Clot Retriever Device

The Thrombite™ endovascular clot retrieval devicesis intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.

Recently, the Billboard of the "Top 50 Most Valuable Investment Companies in China" in 2019 have been unveiled. As the first domestic company with an investment dimension, Venture50 has accompanied China's equity investment market for fourteen years. It is the authoritative reference standard for judging the investment of high-growth companies in the industry, and it is a weathervane that reflects the annual growth potential of the company. Relying on the technological innovation strength and prospects of peripheral intervention and neuro-intervention, Zylox-TonBridge Medical has stood out from more than 7,000 companies, and together with the "Internet celebrities" such as Quick, Zhihu, Himalayan, and Hi Tea, ranked among the "China's most "Top 50 Investment Companies".


Отправить запрос, связаться с поставщиком

Кому: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

PTA Balloon Catheter
PTA Balloon Catheter EASY ACCESS TO THE MOST CHALLENGING ANATOMIES The PTA cathetersare non-reusable semi-compliant coaxial design catheters consisting of an OTWballoo...
Cylone™ Aspiration Catheter
Cylone™ Aspiration Catheter OVERVIEW Cylone™ Aspiration Catheter The Cylone™ aspiration catheter, featuring an end-to-end coil and braid construction, ensures ea...
Snare Retrieval Kit for IVC Filter
Snare Retrieval Kit for IVC Filter zyloxprovides ivc filter retrieval kit, ivc tel, etc. Want to know more about ivc technology, contact us.
Products
Products TONBRIDGE DIALOGUE Focus on the latest points in the neurological intervention field with the help of the media platform in neurological intervent...
Peripheral Stent System
Peripheral Stent System OVERVIEW Peripheral Stent System The ZENFLEX® peripheral vascular disease stentsystem is designed to deliver a self-expanding stent to the il...
Все товары поставщика

Похожие товары

Xiaoniu Rotary Die-cutting Machine Medical I.V. Dressings Plaster Bandage Making Machine
Xiaoniu Rotary Die-cutting Machine Medical I.V. Dressings Plaster Bandage Making Machine Продавец: Xiaoniu Top Ротационная высекальная машина Xiaoniu подходит для нескольких отраслей промышленности, таких как...
Xiaoniu Rotary Die-cutting Machine Medical I.V. Dressings Plaster Bandage Making Machine
Xiaoniu Rotary Die-cutting Machine Medical I.V. Dressings Plaster Bandage Making Machine Продавец: Xiaoniu Top
Wound dressing making machine
Wound dressing making machine Продавец: Xiaoniu Top
Машина для изготовления листов проволочных гелевых электродов
Машина для изготовления листов проволочных гелевых электродов Продавец: Xiaoniu Top Машина для изготовления листов проволочных гелевых электродов
Упаковочная машина для высечки инфузионных палочек
Упаковочная машина для высечки инфузионных палочек Продавец: Xiaoniu Top Высечка инфузионных палочек на упаковочной машине