Thrombite™ Clot Retriever Device
OVERVIEW
Thrombite™ Clot Removal Device
HELICAL OPEN-SIDE STRUCTURE
HIGHER ACUTE RECANALIZATION RATE
The Thrombite™ Mechanical Clot RetrievalDevice, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.
PRODUCT FEATURES
HELICAL OPEN-SIDE STRUCTURE
enables Thrombite™ retriever to efficiently entwine and clamp the clot
assures clot retention for confident removal and revascularization
OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE
increases contact surface with thrombus and maximizes clot integration
EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION
optimizes clot retention during smooth navigation through the tortuous anatomies
PRODUCT FEATURES
Radiopaque markers on the distal end of the device increase device visibility
3 markers for the sizes with 3.0 and 4.0mm diameter
4 markers for the sizes with 5.0 and 6.0mm diameter
Advanced stent surface treatment process
RADIAL FORCE
High radial force is designed for clot integration at the initial stage of stent expansion
Low radial force at nominal stent diameter ensures atraumatic retrieval
RADIAL FORCE
How a Stent Retriever ProcedureIs Performed
Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body.
ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE
STENT RETRIEVAL DEVICE STRUCTURE
Thrombite™ |
Product code |
Diameter D(mm) |
Recommended Vessel Diameter(mm)Min. Max. |
Recommende Microcatheter ID (inch) |
Working Length A(mm) |
Stent Length B(mm) |
System Length(mm) |
|
3MM |
CRD-3-15 |
3 |
15 |
27 |
1900 |
|||
CRD-3-20 |
3 |
20 |
32 |
1900 |
||||
CRD-3-25 |
3 |
25 |
37 |
1900 |
||||
CRD-3-30 |
3 |
30 |
42 |
1900 |
||||
4MM |
CRD-4-15 |
4 |
15 |
27 |
1900 |
|||
CRD-4-20 |
4 |
20 |
32 |
1900 |
||||
CRD-4-25 |
4 |
25 |
37 |
1900 |
||||
CRD-4-30 |
4 |
30 |
42 |
1900 |
||||
5MM |
CRD-5-15 |
5 |
15 |
27 |
1900 |
|||
CRD-5-20 |
5 |
20 |
32 |
1900 |
||||
CRD-5-25 |
5 |
25 |
37 |
1900 |
||||
CRD-5-30 |
5 |
30 |
42 |
1900 |
||||
6MM |
CRD-6-15 |
6 |
15 |
27 |
1900 |
|||
CRD-6-20 |
6 |
20 |
32 |
1900 |
||||
CRD-6-25 |
6 |
25 |
37 |
1900 |
||||
CRD-6-30 |
6 |
30 |
42 |
1900 |
INDICATIONS
Thrombite™ Clot Retriever Device
The Thrombite™ endovascular clot retrieval devicesis intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.
Recently, the Billboard of the "Top 50 Most Valuable Investment Companies in China" in 2019 have been unveiled. As the first domestic company with an investment dimension, Venture50 has accompanied China's equity investment market for fourteen years. It is the authoritative reference standard for judging the investment of high-growth companies in the industry, and it is a weathervane that reflects the annual growth potential of the company. Relying on the technological innovation strength and prospects of peripheral intervention and neuro-intervention, Zylox-TonBridge Medical has stood out from more than 7,000 companies, and together with the "Internet celebrities" such as Quick, Zhihu, Himalayan, and Hi Tea, ranked among the "China's most "Top 50 Investment Companies".
在线联系供应商
Other supplier products
Drug Coated PTA Balloon Catheter | OVERVIEW Drug Coated PTA BalloonCatheter ENSURE EFFECTIVE DRUG DELIVERY OF A SAFE THERAPEUTIC DOSAGE The Drug-Coated PTA Balloon Catheter, a ver... | |
Ultrasonic Surgical System | As one of the leading neurovascular and peripheral vascular device companiesin China, Zylox-Tonbridge provides high-value-added vascular medical de... | |
PTA Balloon Catheter | EASY ACCESS TO THE MOST CHALLENGING ANATOMIES The PTA cathetersare non-reusable semi-compliant coaxial design catheters consisting of an OTWballoo... | |
Distal Access Catheter | For more informationabout distal access catheterand distal access,please feel free to contact us! Zyloxisa leading player in the peripheral and ... | |
PTA Balloon Catheter | EASY ACCESS TO THE MOST CHALLENGING ANATOMIES The Percutaneous Transluminal Angioplasty (PTA) Balloon Catheters are non-reusable semi-compliant co... |
Same products
带加线装置电极片生产机 | 卖方: Xiaoniu Top | 电极片生产机,带加线装置 | |
输液贴模切包装机 | 卖方: Xiaoniu Top | 输液贴模切+包装机 | |
医疗敷贴模切包装机 | 卖方: Xiaoniu Top | 医疗敷帖模切+包装机 | |
扣式理疗片生产机 | 卖方: Xiaoniu Top | 扣式理疗片生产机圆刀模切机 | |
不干胶涂布模切包装机 | 卖方: Xiaoniu Top | 9工位模切机配热包装装置,输液贴模切包装机 |