.

Thrombite™ Clot Retriever Device

OVERVIEW

Thrombite™ Clot Removal Device

HELICAL OPEN-SIDE STRUCTURE

HIGHER ACUTE RECANALIZATION RATE

The Thrombite™ Mechanical Clot RetrievalDevice, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.

PRODUCT FEATURES

HELICAL OPEN-SIDE STRUCTURE

enables Thrombite™ retriever to efficiently entwine and clamp the clot

assures clot retention for confident removal and revascularization

OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE

increases contact surface with thrombus and maximizes clot integration

EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION

optimizes clot retention during smooth navigation through the tortuous anatomies

PRODUCT FEATURES

Radiopaque markers on the distal end of the device increase device visibility

3 markers for the sizes with 3.0 and 4.0mm diameter

4 markers for the sizes with 5.0 and 6.0mm diameter

Advanced stent surface treatment process

RADIAL FORCE

High radial force is designed for clot integration at the initial stage of stent expansion

Low radial force at nominal stent diameter ensures atraumatic retrieval

RADIAL FORCE

How a Stent Retriever ProcedureIs Performed

Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body.

ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE

STENT RETRIEVAL DEVICE STRUCTURE

Thrombite™

Product code

Diameter D(mm)

Recommended Vessel Diameter(mm)Min. Max.

Recommende Microcatheter ID (inch)

Working Length A(mm)

Stent Length B(mm)

System Length(mm)

3MM

CRD-3-15

3

15

27

1900

CRD-3-20

3

20

32

1900

CRD-3-25

3

25

37

1900

CRD-3-30

3

30

42

1900

4MM

CRD-4-15

4

15

27

1900

CRD-4-20

4

20

32

1900

CRD-4-25

4

25

37

1900

CRD-4-30

4

30

42

1900

5MM

CRD-5-15

5

15

27

1900

CRD-5-20

5

20

32

1900

CRD-5-25

5

25

37

1900

CRD-5-30

5

30

42

1900

6MM

CRD-6-15

6

15

27

1900

CRD-6-20

6

20

32

1900

CRD-6-25

6

25

37

1900

CRD-6-30

6

30

42

1900

INDICATIONS

Thrombite™ Clot Retriever Device

The Thrombite™ endovascular clot retrieval devicesis intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.

Recently, the Billboard of the "Top 50 Most Valuable Investment Companies in China" in 2019 have been unveiled. As the first domestic company with an investment dimension, Venture50 has accompanied China's equity investment market for fourteen years. It is the authoritative reference standard for judging the investment of high-growth companies in the industry, and it is a weathervane that reflects the annual growth potential of the company. Relying on the technological innovation strength and prospects of peripheral intervention and neuro-intervention, Zylox-TonBridge Medical has stood out from more than 7,000 companies, and together with the "Internet celebrities" such as Quick, Zhihu, Himalayan, and Hi Tea, ranked among the "China's most "Top 50 Investment Companies".



在线联系供应商

至: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

High Pressure PTA Balloon Catheter
High Pressure PTA Balloon Catheter OVERVIEW High Pressure PTA Balloon Catheter Deliver great outcomes for both AV and vascular access patency The Percutaneous Transluminal Angio...
Vascular Interventions
Vascular Interventions ZyloxTonbridge provides high-value-added vascular medical devices. As one of the leading neurovascular andperipheral vascular companiesin China, we...
NEURO INTERVENTIONS
NEURO INTERVENTIONS NEURO INTERVENTIONS One of the top neurovascular device companiesin China The pursuit of excellence is the best expression of care for life and o...
Drug Coated PTA Balloon Catheter
Drug Coated PTA Balloon Catheter OVERVIEW Drug CoatedBallonPTACatheter ENSURE EFFECTIVE DRUG DELIVERY OF A SAFE THERAPEUTIC DOSAGE The drug eluting balloon catheter, a versatile...
Aspira Catheter Instructions
Aspira Catheter Instructions Aspira Catheter Instructions What Is An Aspiration Catheter? The Cylone™ Aspiration Catheter is intended for use in the removal/aspiratio...
供应产品

Same products

带加线装置电极片生产机
带加线装置电极片生产机 卖方: Xiaoniu Top 电极片生产机,带加线装置
输液贴模切包装机
输液贴模切包装机 卖方: Xiaoniu Top 输液贴模切+包装机
医疗敷贴模切包装机
医疗敷贴模切包装机 卖方: Xiaoniu Top 医疗敷帖模切+包装机
扣式理疗片生产机
扣式理疗片生产机 卖方: Xiaoniu Top 扣式理疗片生产机圆刀模切机
不干胶涂布模切包装机
不干胶涂布模切包装机 卖方: Xiaoniu Top 9工位模切机配热包装装置,输液贴模切包装机