Thrombite™ Clot Retriever Device
OVERVIEW
Thrombite™ Clot Removal Device
HELICAL OPEN-SIDE STRUCTURE
HIGHER ACUTE RECANALIZATION RATE
The Thrombite™ Mechanical Clot RetrievalDevice, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.
PRODUCT FEATURES
HELICAL OPEN-SIDE STRUCTURE
enables Thrombite™ retriever to efficiently entwine and clamp the clot
assures clot retention for confident removal and revascularization
OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE
increases contact surface with thrombus and maximizes clot integration
EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION
optimizes clot retention during smooth navigation through the tortuous anatomies
PRODUCT FEATURES
Radiopaque markers on the distal end of the device increase device visibility
3 markers for the sizes with 3.0 and 4.0mm diameter
4 markers for the sizes with 5.0 and 6.0mm diameter
Advanced stent surface treatment process
RADIAL FORCE
High radial force is designed for clot integration at the initial stage of stent expansion
Low radial force at nominal stent diameter ensures atraumatic retrieval
RADIAL FORCE
How a Stent Retriever ProcedureIs Performed
Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever will be extracted along with the clot and finally leave your body.
ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE
STENT RETRIEVAL DEVICE STRUCTURE
Thrombite™ |
Product code |
Diameter D(mm) |
Recommended Vessel Diameter(mm)Min. Max. |
Recommende Microcatheter ID (inch) |
Working Length A(mm) |
Stent Length B(mm) |
System Length(mm) |
|
3MM |
CRD-3-15 |
3 |
15 |
27 |
1900 |
|||
CRD-3-20 |
3 |
20 |
32 |
1900 |
||||
CRD-3-25 |
3 |
25 |
37 |
1900 |
||||
CRD-3-30 |
3 |
30 |
42 |
1900 |
||||
4MM |
CRD-4-15 |
4 |
15 |
27 |
1900 |
|||
CRD-4-20 |
4 |
20 |
32 |
1900 |
||||
CRD-4-25 |
4 |
25 |
37 |
1900 |
||||
CRD-4-30 |
4 |
30 |
42 |
1900 |
||||
5MM |
CRD-5-15 |
5 |
15 |
27 |
1900 |
|||
CRD-5-20 |
5 |
20 |
32 |
1900 |
||||
CRD-5-25 |
5 |
25 |
37 |
1900 |
||||
CRD-5-30 |
5 |
30 |
42 |
1900 |
||||
6MM |
CRD-6-15 |
6 |
15 |
27 |
1900 |
|||
CRD-6-20 |
6 |
20 |
32 |
1900 |
||||
CRD-6-25 |
6 |
25 |
37 |
1900 |
||||
CRD-6-30 |
6 |
30 |
42 |
1900 |
INDICATIONS
Thrombite™ Clot Retriever Device
The Thrombite™ endovascular clot retrieval devicesis intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.
Recently, the Billboard of the "Top 50 Most Valuable Investment Companies in China" in 2019 have been unveiled. As the first domestic company with an investment dimension, Venture50 has accompanied China's equity investment market for fourteen years. It is the authoritative reference standard for judging the investment of high-growth companies in the industry, and it is a weathervane that reflects the annual growth potential of the company. Relying on the technological innovation strength and prospects of peripheral intervention and neuro-intervention, Zylox-TonBridge Medical has stood out from more than 7,000 companies, and together with the "Internet celebrities" such as Quick, Zhihu, Himalayan, and Hi Tea, ranked among the "China's most "Top 50 Investment Companies".
Send product request
Other supplier products
High Pressure PTA Balloon Catheter | OVERVIEW High Pressure PTA Balloon Catheter Deliver great outcomes for both AV and vascular access patency The Percutaneous Transluminal Angio... | |
Peripheral Drug-eluting Stent System | OVERVIEW Peripheral Drug-eluting Stent System ZENFLEX® Pro Peripheral Drug-eluting Stent System, the 3rd peripheral drug-eluting stent in the... | |
Thrombite™ Clot Retriever Device | OVERVIEW Thrombite™ Clot Retriever Device HELICAL OPEN-SIDE STRUCTURE HIGHER ACUTE RECANALIZATION RATE The Thrombite™ endovascular ... | |
ZENFlow Tiger™ LD PTA Dilatation Catheter | OVERVIEW ZENFlow Tiger™ LD PTA Dilatation Catheter Large balloon diameters up to 25mm A unique low temperature molding technology, ensur... | |
Peripheral Stent System | OVERVIEW Peripheral Stent System The ZENFLEX® peripheral vascular disease stentsystem is designed to deliver a self-expanding stent to the il... |
Same products
Wire gel electrode sheet machine | Seller: Xiaoniu Top | Wire gel electrode sheet machine | |
Infusion stick die cutting packaging machine | Seller: Xiaoniu Top | infusion stick die cutting with packaging machine | |
medical dressing wound dressing die cutting packaging machine | Seller: Xiaoniu Top | medical dressing wound dressing die cutting with packaging machine | |
ECG Button electrode sheet machine | Seller: Xiaoniu Top | sensor stud style ECG electrodes Sheet producing machine | |
Adhesive coating die cutting packaging machine | Seller: Xiaoniu Top | 9 work station die cutting machine add hot packaging equipment, Infusion stick die cutting packag... |