.

MemoPart™ Patent Ductus Arteriosus (PDA) Occluder

MemoPart™
Multiple designs, anastomosing lesions

MemoPart™ Patent Ductus Arteriosus (PDA) Occluder Details


Product Description
MemoPart™ PDA Occluder is a self-expandable device made from nitinol wire mesh. Aretention skirt on the aortic side provides secure positioning in the ampulla of the ductus. As the occluder is implanted, it expands outward and the wires push against the wall of the ductus. Polyester fabric is sewn into the occluder with polyester thread.The fabric induces thrombosis that closes the communication.

Product Features
Modified rigidity and flexibility for different type of occluders - balanced stiffness of Patent Ductus Arteriosus Occluder (PDAO) ensures the optimal occlusion performance.

Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.

The hubless design of Patent Ductus Arteriosus Occluder (PDAO) helps with earlier endothelialization to minimize the risk of thrombosis.

Indications for Use
The MemoPart™ Patent Ductus Arteriosus (PDA) Occluder can be used for the nonsurgical closure of apatent ductus arteriosus (PDA) in the percutaneous, transcatheter therapy.

Ordering Information
Cone Shape PDA Occluder Device

Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)




WBFDQ- Ⅱ 06 406 6 4 10 6
WBFDQ- Ⅱ 08 608 8 6 12 6.5
WBFDQ- Ⅱ 10 810 10 8 14 7.5
WBFDQ- Ⅱ 12 1012 12 10 16 8.5
WBFDQ- Ⅱ 14 1214 14 12 18 9.5
WBFDQ- Ⅱ 16 1416 16 14 20 10.5
WBFDQ- Ⅱ 18 1618 18 16 23 10.5
WBFDQ- Ⅱ 20 1820 20 18 25 12
WBFDQ- Ⅱ 22 2022 22 20 27 12

Hubless Cone Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)




WTWBFDQ- Ⅱ 06 406 6 4 10 6
WTWBFDQ- Ⅱ 08 608 8 6 12 6.5
WTWBFDQ- Ⅱ 10 810 10 8 14 7.5
WTWBFDQ- Ⅱ 12 1012 12 10 16 8.5
WTWBFDQ- Ⅱ 14 1214 14 12 18 9.5
WTWBFDQ- Ⅱ 16 1416 16 14 20 10.5
WTWBFDQ- Ⅱ 18 1618 18 16 23 10.5
WTWBFDQ- Ⅱ 20 1820 20 18 25 12
WTWBFDQ- Ⅱ 22 2022 22 20 27 12

Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder

Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)




WBFDQ- Ⅰ 04 4 4 4 8 4.0
WBFDQ- Ⅰ 05 5 5 5 9 5.0
WBFDQ- Ⅰ 06 6 6 6 10 6.0
WBFDQ- Ⅰ 07 7 7 7 11 6.5
WBFDQ- Ⅰ 08 8 8 8 12 6.5
WBFDQ- Ⅰ 09 9 9 9 13 7
WBFDQ- Ⅰ 10 10 10 10 14 7.5
WBFDQ- Ⅰ 11 11 11 11 15 8
WBFDQ- Ⅰ 12 12 12 12 16 8.5
WBFDQ- Ⅰ 13 13 13 13 17 8.5
WBFDQ- Ⅰ 14 14 14 14 18 9.5
WBFDQ- Ⅰ 16 16 16 16 21 10.5
WBFDQ- Ⅰ 18 18 18 18 23 10.5
WBFDQ- Ⅰ 20 20 20 20 25 12
WBFDQ- Ⅰ 22 22 22 22 27 12

Hubless Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder

Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)




WTWBFDQ- Ⅰ 04 4 4 4 8 4
WTWBFDQ- Ⅰ 05 5 5 5 9 5
WTWBFDQ- Ⅰ 06 6 6 6 10 6
WTWBFDQ- Ⅰ 07 7 7 7 11 6.5
WTWBFDQ- Ⅰ 08 8 8 8 12 6.5
WTWBFDQ- Ⅰ 09 9 9 9 13 7
WTWBFDQ- Ⅰ 10 10 10 10 14 7.5
WTWBFDQ- Ⅰ 11 11 11 11 15 8
WTWBFDQ- Ⅰ 12 12 12 12 16 8.5
WTWBFDQ- Ⅰ 13 13 13 13 17 8.5
WTWBFDQ- Ⅰ 14 14 14 14 18 9.5
WTWBFDQ- Ⅰ 16 16 16 16 21 10.5
WTWBFDQ- Ⅰ 18 18 18 18 23 10.5
WTWBFDQ- Ⅰ 20 20 20 20 25 12
WTWBFDQ- Ⅰ 22 22 22 22 27 12

Today, Lepu Medical has grown into a global leading group company in the fields of cardiovascular interventions, structural heart diseases, neurointervention, cardiac rhythm management, anesthesia and critical care, in vitro diagnostics, ECG & patient monitoring, hemodialysis, orthopedics, skin care and general surgery.

Now the price of china medical supplies wholesale is reasonable, if you have needs, please leave us a message.


Отправить запрос, связаться с поставщиком

Кому: Lepu Medical Technology(Beijing)Co.,Ltd
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

3-Aminopyrazine -2- carboxylic acid
3-Aminopyrazine -2- carboxylic acid 3-Aminopyrazine -2- carboxylic acid Item/Code CAS No. Molecular Structure Therapeutic Area Certification/Stage ...
Types of Coronary Stents
Types of Coronary Stents Types of Coronary Stents NeoVas™ Sirolimus-eluting Bioresorbable Coronary Scaffold System Sirolimus-eluting Bioresorbable Coronary Scaffold ...
Sertraline HCl
Sertraline HCl Sertraline HCl Item/Code CAS No. Molecular Structure Therapeutic Area Certification/Stage API 79617-99...
Patient Monitor
Patient Monitor With the functions of real-time recording and displaying parameters, multi-functional instrument is designed for monitoring the vital physiological...
CFMS LEPU-8880
CFMS LEPU-8880 Features Fast, accurate, convenient and intelligent. Evaluate the prenatal prothrombotic state and prepare the essential treatment as early as pos...
Все товары поставщика

Похожие товары

Xiaoniu Rotary Die-cutting Machine Medical I.V. Dressings Plaster Bandage Making Machine
Xiaoniu Rotary Die-cutting Machine Medical I.V. Dressings Plaster Bandage Making Machine Продавец: Xiaoniu Top Ротационная высекальная машина Xiaoniu подходит для нескольких отраслей промышленности, таких как...
Xiaoniu Rotary Die-cutting Machine Medical I.V. Dressings Plaster Bandage Making Machine
Xiaoniu Rotary Die-cutting Machine Medical I.V. Dressings Plaster Bandage Making Machine Продавец: Xiaoniu Top
Wound dressing making machine
Wound dressing making machine Продавец: Xiaoniu Top
Машина для изготовления листов проволочных гелевых электродов
Машина для изготовления листов проволочных гелевых электродов Продавец: Xiaoniu Top Машина для изготовления листов проволочных гелевых электродов
Упаковочная машина для высечки инфузионных палочек
Упаковочная машина для высечки инфузионных палочек Продавец: Xiaoniu Top Высечка инфузионных палочек на упаковочной машине