MemoPart™ Patent Ductus Arteriosus (PDA) Occluder
MemoPart™
Multiple designs, anastomosing lesions
MemoPart™ Patent Ductus Arteriosus (PDA) Occluder Details
Product Description
MemoPart™ PDA Occluder is a self-expandable device made from nitinol wire mesh. Aretention skirt on the aortic side provides secure positioning in the ampulla of the ductus. As the occluder is implanted, it expands outward and the wires push against the wall of the ductus. Polyester fabric is sewn into the occluder with polyester thread.The fabric induces thrombosis that closes the communication.
Product Features
Modified rigidity and flexibility for different type of occluders - balanced stiffness of Patent Ductus Arteriosus Occluder (PDAO) ensures the optimal occlusion performance.
Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.
The hubless design of Patent Ductus Arteriosus Occluder (PDAO) helps with earlier endothelialization to minimize the risk of thrombosis.
Indications for Use
The MemoPart™ Patent Ductus Arteriosus (PDA) Occluder can be used for the nonsurgical closure of apatent ductus arteriosus (PDA) in the percutaneous, transcatheter therapy.
Ordering Information
Cone Shape PDA Occluder Device
Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)
WBFDQ- Ⅱ 06 406 6 4 10 6
WBFDQ- Ⅱ 08 608 8 6 12 6.5
WBFDQ- Ⅱ 10 810 10 8 14 7.5
WBFDQ- Ⅱ 12 1012 12 10 16 8.5
WBFDQ- Ⅱ 14 1214 14 12 18 9.5
WBFDQ- Ⅱ 16 1416 16 14 20 10.5
WBFDQ- Ⅱ 18 1618 18 16 23 10.5
WBFDQ- Ⅱ 20 1820 20 18 25 12
WBFDQ- Ⅱ 22 2022 22 20 27 12
Hubless Cone Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)
WTWBFDQ- Ⅱ 06 406 6 4 10 6
WTWBFDQ- Ⅱ 08 608 8 6 12 6.5
WTWBFDQ- Ⅱ 10 810 10 8 14 7.5
WTWBFDQ- Ⅱ 12 1012 12 10 16 8.5
WTWBFDQ- Ⅱ 14 1214 14 12 18 9.5
WTWBFDQ- Ⅱ 16 1416 16 14 20 10.5
WTWBFDQ- Ⅱ 18 1618 18 16 23 10.5
WTWBFDQ- Ⅱ 20 1820 20 18 25 12
WTWBFDQ- Ⅱ 22 2022 22 20 27 12
Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)
WBFDQ- Ⅰ 04 4 4 4 8 4.0
WBFDQ- Ⅰ 05 5 5 5 9 5.0
WBFDQ- Ⅰ 06 6 6 6 10 6.0
WBFDQ- Ⅰ 07 7 7 7 11 6.5
WBFDQ- Ⅰ 08 8 8 8 12 6.5
WBFDQ- Ⅰ 09 9 9 9 13 7
WBFDQ- Ⅰ 10 10 10 10 14 7.5
WBFDQ- Ⅰ 11 11 11 11 15 8
WBFDQ- Ⅰ 12 12 12 12 16 8.5
WBFDQ- Ⅰ 13 13 13 13 17 8.5
WBFDQ- Ⅰ 14 14 14 14 18 9.5
WBFDQ- Ⅰ 16 16 16 16 21 10.5
WBFDQ- Ⅰ 18 18 18 18 23 10.5
WBFDQ- Ⅰ 20 20 20 20 25 12
WBFDQ- Ⅰ 22 22 22 22 27 12
Hubless Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)
WTWBFDQ- Ⅰ 04 4 4 4 8 4
WTWBFDQ- Ⅰ 05 5 5 5 9 5
WTWBFDQ- Ⅰ 06 6 6 6 10 6
WTWBFDQ- Ⅰ 07 7 7 7 11 6.5
WTWBFDQ- Ⅰ 08 8 8 8 12 6.5
WTWBFDQ- Ⅰ 09 9 9 9 13 7
WTWBFDQ- Ⅰ 10 10 10 10 14 7.5
WTWBFDQ- Ⅰ 11 11 11 11 15 8
WTWBFDQ- Ⅰ 12 12 12 12 16 8.5
WTWBFDQ- Ⅰ 13 13 13 13 17 8.5
WTWBFDQ- Ⅰ 14 14 14 14 18 9.5
WTWBFDQ- Ⅰ 16 16 16 16 21 10.5
WTWBFDQ- Ⅰ 18 18 18 18 23 10.5
WTWBFDQ- Ⅰ 20 20 20 20 25 12
WTWBFDQ- Ⅰ 22 22 22 22 27 12
Today, Lepu Medical has grown into a global leading group company in the fields of cardiovascular interventions, structural heart diseases, neurointervention, cardiac rhythm management, anesthesia and critical care, in vitro diagnostics, ECG & patient monitoring, hemodialysis, orthopedics, skin care and general surgery.
Now the price of china medical supplies wholesale is reasonable, if you have needs, please leave us a message.
Other supplier products
|
SARS-CoV-2 Antibody Test Kit (Colloidal Gold Immunochromatography) |
Accurate: High-purity antibody with high accuracy
Efficient: Test result is available in 15mins
Convenient: Suitable for finger blood
Plea... |
|
Catheter |
Types of Catheter
Angiographic Catheter
Orien™ Guiding Catheter
Guiding Catheter
Thromsweeper™ Thrombus Extraction Catheter
Th... |
|
Deliver™ Infusion Catheter |
Deliver™
Infusion Catheter
Deliver™ Infusion CatheterDetails
Combined liquid perfusion lumen and guide wire lumen fulfills the per... |
|
MemoPart™ Atrial Septal Defect (ASD) Occluder |
MemoPart™
Accurate occluding, stable clamping
MemoPart™ Atrial Septal Defect (ASD) Occluder Details
ASD occluder deviceDescrip... |
|
Disposable Clip Applier |
Occlude blood vessel and other tissue structures in the endoscopic surgery.
Up to 20 titanium clips hit continuously.
Used in small incision ... |
All supplier products
Same products