MemoPart™ Patent Ductus Arteriosus (PDA) Occluder
MemoPart™
Multiple designs, anastomosing lesions
MemoPart™ Patent Ductus Arteriosus (PDA) Occluder Details
Product Description
MemoPart™ PDA Occluder is a self-expandable device made from nitinol wire mesh. Aretention skirt on the aortic side provides secure positioning in the ampulla of the ductus. As the occluder is implanted, it expands outward and the wires push against the wall of the ductus. Polyester fabric is sewn into the occluder with polyester thread.The fabric induces thrombosis that closes the communication.
Product Features
Modified rigidity and flexibility for different type of occluders - balanced stiffness of Patent Ductus Arteriosus Occluder (PDAO) ensures the optimal occlusion performance.
Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.
The hubless design of Patent Ductus Arteriosus Occluder (PDAO) helps with earlier endothelialization to minimize the risk of thrombosis.
Indications for Use
The MemoPart™ Patent Ductus Arteriosus (PDA) Occluder can be used for the nonsurgical closure of apatent ductus arteriosus (PDA) in the percutaneous, transcatheter therapy.
Ordering Information
Cone Shape PDA Occluder Device
Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)
WBFDQ- Ⅱ 06 406 6 4 10 6
WBFDQ- Ⅱ 08 608 8 6 12 6.5
WBFDQ- Ⅱ 10 810 10 8 14 7.5
WBFDQ- Ⅱ 12 1012 12 10 16 8.5
WBFDQ- Ⅱ 14 1214 14 12 18 9.5
WBFDQ- Ⅱ 16 1416 16 14 20 10.5
WBFDQ- Ⅱ 18 1618 18 16 23 10.5
WBFDQ- Ⅱ 20 1820 20 18 25 12
WBFDQ- Ⅱ 22 2022 22 20 27 12
Hubless Cone Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)
WTWBFDQ- Ⅱ 06 406 6 4 10 6
WTWBFDQ- Ⅱ 08 608 8 6 12 6.5
WTWBFDQ- Ⅱ 10 810 10 8 14 7.5
WTWBFDQ- Ⅱ 12 1012 12 10 16 8.5
WTWBFDQ- Ⅱ 14 1214 14 12 18 9.5
WTWBFDQ- Ⅱ 16 1416 16 14 20 10.5
WTWBFDQ- Ⅱ 18 1618 18 16 23 10.5
WTWBFDQ- Ⅱ 20 1820 20 18 25 12
WTWBFDQ- Ⅱ 22 2022 22 20 27 12
Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)
WBFDQ- Ⅰ 04 4 4 4 8 4.0
WBFDQ- Ⅰ 05 5 5 5 9 5.0
WBFDQ- Ⅰ 06 6 6 6 10 6.0
WBFDQ- Ⅰ 07 7 7 7 11 6.5
WBFDQ- Ⅰ 08 8 8 8 12 6.5
WBFDQ- Ⅰ 09 9 9 9 13 7
WBFDQ- Ⅰ 10 10 10 10 14 7.5
WBFDQ- Ⅰ 11 11 11 11 15 8
WBFDQ- Ⅰ 12 12 12 12 16 8.5
WBFDQ- Ⅰ 13 13 13 13 17 8.5
WBFDQ- Ⅰ 14 14 14 14 18 9.5
WBFDQ- Ⅰ 16 16 16 16 21 10.5
WBFDQ- Ⅰ 18 18 18 18 23 10.5
WBFDQ- Ⅰ 20 20 20 20 25 12
WBFDQ- Ⅰ 22 22 22 22 27 12
Hubless Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. Device
Size B
Aortic Waist Diameter (mm) C
Pulmonic Waist Diameter
(mm) A
Aortic Disc Diameter (mm) H
Waist Length (mm)
WTWBFDQ- Ⅰ 04 4 4 4 8 4
WTWBFDQ- Ⅰ 05 5 5 5 9 5
WTWBFDQ- Ⅰ 06 6 6 6 10 6
WTWBFDQ- Ⅰ 07 7 7 7 11 6.5
WTWBFDQ- Ⅰ 08 8 8 8 12 6.5
WTWBFDQ- Ⅰ 09 9 9 9 13 7
WTWBFDQ- Ⅰ 10 10 10 10 14 7.5
WTWBFDQ- Ⅰ 11 11 11 11 15 8
WTWBFDQ- Ⅰ 12 12 12 12 16 8.5
WTWBFDQ- Ⅰ 13 13 13 13 17 8.5
WTWBFDQ- Ⅰ 14 14 14 14 18 9.5
WTWBFDQ- Ⅰ 16 16 16 16 21 10.5
WTWBFDQ- Ⅰ 18 18 18 18 23 10.5
WTWBFDQ- Ⅰ 20 20 20 20 25 12
WTWBFDQ- Ⅰ 22 22 22 22 27 12
Today, Lepu Medical has grown into a global leading group company in the fields of cardiovascular interventions, structural heart diseases, neurointervention, cardiac rhythm management, anesthesia and critical care, in vitro diagnostics, ECG & patient monitoring, hemodialysis, orthopedics, skin care and general surgery.
Now the price of china medical supplies wholesale is reasonable, if you have needs, please leave us a message.
Other supplier products
|
LFR30B Infrared Forehead Thermometer |
Blue dots focusing calibration system help users to find the optimal measuring distance
LFR30B medical infrared forehead thermometerare designed f... |
|
Types of Coronary Stents |
Types of Coronary Stents
NeoVas™ Sirolimus-eluting Bioresorbable Coronary Scaffold System
Sirolimus-eluting Bioresorbable Coronary Scaffold ... |
|
Equipments |
Lepu Medical Technology ( Beijing ) Co., Ltd was established in 1999. As a professional lepu medical technologygroup, it is specialized in developi... |
|
CFMS LEPU-8880 |
Features
Fast, accurate, convenient and intelligent.
Evaluate the prenatal prothrombotic state and prepare the essential treatment as early as ... |
|
Lesinurad |
Lesinurad
Item/Code
CAS No.
Molecular Structure
Therapeutic Area
Certification/Stage
LES10
Hyperuricemia
Under developme... |
供应产品
Same products