Infusion Apparatus Leakage Positive Pressure Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The M102 Infusion Apparatus Leakage Positive Pressure Tester is designed to evaluate the airtightness and sealing performance of medical injection syringes and infusion apparatus. It provides precise measurement of positive pressure integrity, ensuring that medical devices meet required safety standards. This instrument is widely used in laboratories, production quality control, and third-party certification testing.
Application
M102 Infusion apparatus leakage positive pressure tester, Itis suitable for the measurement of positive pressure airtight of medical infusion apparatus, blood transfusion devices, infusion needles, anesthesia bag filters, pipelines, conduits, quick joints, and etc. It can accurately measure whether the sealing performance of injection syringe meets the specified requirements.
It is applicable to the performance verification of new products, quality control of the production department, and the of material properties for the third-party testing organization, the product performance verification laboratory, and the quality and technical supervisiondepartment, etc.
The M102 tester is suitable for testing the positive pressure airtightness of medical devices in the following industries and products:
(1) Medical Devices: injection syringes, infusion sets, anesthesia bag filters — verification of sealing integrity under positive pressure
(2) Blood Transfusion Equipment: transfusion devices, infusion needles — assessment of airtightness to prevent leakage
(3) Pipelines and Conduits: medical tubing, quick joints, and connectors — evaluation of fluid-tight connections
(4) Research and Development: new infusion device prototypes, design optimization for airtight performance
(5) Quality Control Laboratories: production inspection of medical infusion devices to ensure compliance with standards
(6) Certification and Regulatory Testing: third-party laboratories performing performance verification for national and international medical device standards
Standards
The instrument complies with the following standards, including relevant international regulations:
(1) GB 8368-2005 – Disposable Infusion Sets for Single Use — Gravity Infusion Type, including airtightness requirements
(2) ISO 8536-4:2010 – Infusion equipment for medical use — Part 4: Infusion sets for single use, including leak testing methods
(3) ISO 13485:2016 – Medical devices — Quality management systems — Requirements for regulatory purposes (applies to testing and QC of infusion devices)
(4) ASTM F2392-04 – Standard Guide for Leak Testing of Medical Fluid Delivery Devices
Features
(1) Touch-tone control panel with LED digital display for easy operation
(2) Adjustable test pressure range: 0–100 kPa, with ≤ ±2.5% reading error
(3) Flexible test time setting (1–16 s) to meet various requirements
(4) Compact and portable design, suitable for laboratory or production line installation
(5) Automatic operation mode reduces manual intervention
(6) Accurate measurement ensures compliance with medical device safety standards
Technical Parameters
| Item | Specification |
|---|---|
| Control Mode | Automatic |
| Test Pressure Range | 0–100 kPa |
| Pressure Accuracy | ±0.5 kPa |
| Test Time | 1–16 s (adjustable) |
| Weight | 30 kg |
| Power Supply | AC 220 V, 50 Hz |
| Appearance Size | 40 cm × 45 cm × 45 cm |
Accessories
(1) Standard air source connector
(2) Sample fixture for injection syringes and infusion devices
(3) Power cable
(4) Operation manual
(5) Calibration certificate
Operating instructions
1. Turn on the power and turn on the power.
2. Click "next" and enter "main menu". There are four options of "setting", "test", "measurement" and "air release".
3. Click "setting", set the "stress" can be performed at this time, set the "time", "" date and time setting, just enter thecorresponding project selection and vessels of the specifications of the corresponding parameters can be confirmed to betested.
4. Click "set pressure" and click the corresponding number of test pressure to "confirm". (unit: Kpa. "Confirm" and return toset parameters.
5. Click "set time", and then click the corresponding number for the test to "confirm". Unit: seconds. "Confirm" and returnto set parameters.
6. Click "date & time". After clicking "date", enter the date of the test day to be confirmed. (the format is:year/month/day, change of time is similar to change of date. (" confirm "and return to the main menu.)
7. After clicking "measurement", first connect the standard air source, and then measure whether the internal data isstandard. This step is not required for normal operation. This option is used for metering authentication.
8. Click "release", i.e. the internal test data pressure value is clear.
9. See the "main menu" shown in the content and the vessels being measured parameters are set by matching, can click on the"test", after the test according to test results, a visual check to see if the set with the test values of qualified, clickon the "qualified" or "unqualified" after the "print". "Return" returns to the main menu.
Maintenance Information
(1) Keep the instrument clean and dry after each test
(2) Inspect connectors, sample holders, and air supply lines for wear or leaks
(3) Calibrate pressure sensors regularly to maintain accuracy
(4) Avoid excessive force or impact on the instrument to prevent damage
(5) Store in a safe, ventilated environment
(6) Maintain operation and calibration logs for regulatory compliance
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| ASTM Standard Reciprocating Abrasion Tester | Taber 5900 Wear & Mar Resistance Equipment | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Features Reciprocating wear machine is usefor detecting the Scra... | |
| Automotive Wire Harness Swing Test Equipment Factory Direct | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Parameters ParameterSpecification Test Speed 10–60 cycles/... | |
| Total Knee Joint Prostheses Wear Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 14243-1:2014: Specifies wear testing parameters for total knee prostheses, in... | |
| Prefilled Syringe Plunger Force Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications - Quality Control and Supervision The push - force tester for prefilled syrin... | |
| Powder Wet Vibrating Screen System For Lithium Battery Material Testing | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM E11: Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves ... |
Похожие товары
| pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester | Продавец: Коллирон электроникс лимитед | Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent... | |
| ORP-2026S Waterproof Soil ORP and Temperature Meter | Продавец: Коллирон электроникс лимитед | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| TDS-2616 Waterproof EC/TDS/Temperature Meter | Продавец: Коллирон электроникс лимитед | Range EC ~19.9mS TDS Temp 0~50℃ R... | |
| EC-98330 CF ECOstick - Nutrient Tester | Продавец: Коллирон электроникс лимитед | Ideal for hydroponics and agriculture applications, theNutrient Tester accurately measures the el... | |
| PH-808 Waterproof Soil PH Meter | Продавец: Коллирон электроникс лимитед | Model PH-808 Range PH ~14.00PH Temp 0~50℃ ... |