Automatic voltage internal resistance tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Automatic Voltage & Internal Resistance Tester is a precision electrical testing instrument designed for rapid and accurate measurement of open-circuit voltage (OCV) and DC internal resistance of lithium-ion battery cells. The system is widely used in battery research laboratories, production lines, and quality control departments to evaluate electrical consistency, detect defective cells, and support battery performance classification and safety assessment.
Application
(1) Open-circuit voltage (OCV) measurement of lithium-ion pouch cells, cylindrical cells, and coin cells.
(2) DC internal resistance measurement for cell grading and sorting.
(3) Incoming inspection of battery cells and semi-finished products.
(4) Quality control during cell production, formation, and aging processes.
(5) Electrical consistency evaluation for batch comparison and statistical analysis.
(6) Screening of abnormal cells with high internal resistance or voltage deviation.
(7) Laboratory research and process validation for battery development.
Standards
(1) IEC 62660-2 – Secondary Lithium-Ion Cells – Reliability and Abuse Testing (reference application).
(2) ASTM E83 – Verification of Linear Displacement Measuring Systems (instrument calibration reference).
(3) ISO 3611 – Verification of Linear Measuring Instruments (instrument calibration reference).
(4) RoHS – Restriction of Hazardous Substances Directive.
(5) CE Certification – Conformité Européenne.
Features
(1) Simultaneous measurement of voltage and internal resistance with high accuracy.
(2) Automated test sequence reduces operator influence and improves repeatability.
(3) Fast measurement suitable for production-line and batch testing.
(4) Wide compatibility with pouch, cylindrical, and coin-type battery cells.
(5) Stable contact design ensures reliable electrical connection.
(6) Built-in data storage and result classification functions.
(7) Digital communication interface for data export and system integration.
(8) Electrical safety protection with overload and short-circuit prevention.
Technical Parameters
| Parameter | Specification |
|---|---|
| Voltage Measurement Range | 0 – 10 V |
| Voltage Measurement Accuracy | ±0.05% F.S |
| Internal Resistance Range | 0.01 mΩ – 1,000 mΩ |
| Internal Resistance Accuracy | ±0.5% F.S |
| Measurement Method | DC pulse method |
| Measurement Time | ≤ 1 s per cell |
| Data Storage | ≥ 100,000 records |
| Communication Interface | USB / RS232 / Ethernet (optional) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 300 × 250 × 400 mm |
| Weight | 15 kg (net) / 18 kg (gross) |
Accessories
(1) Battery test fixture for pouch, cylindrical, and coin cells.
(2) Kelvin test leads and probe assemblies.
(3) Calibration resistor set for internal resistance verification.
(4) Data acquisition and analysis software.
(5) Power cables and grounding accessories.
(6) Operation and maintenance manual.
(7) Compliance and calibration certificates.
Test Procedure
(1) Power on the tester and allow system self-check.
(2) Perform calibration using certified voltage sources and standard resistors.
(3) Place the battery cell into the appropriate test fixture.
(4) Ensure correct polarity and stable electrical contact.
(5) Start the test sequence to measure voltage and internal resistance.
(6) Display, store, and export the test results as required.
Maintenance Information
(1) Keep test probes and fixtures clean to ensure stable contact resistance.
(2) Periodically verify measurement accuracy using standard resistors.
(3) Inspect cables and connectors for wear or damage.
(4) Avoid exposure to corrosive gases, electrolyte leakage, or high humidity.
(5) Store the instrument in a clean and temperature-controlled environment when not in use.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Advanced thermal self-ignition tester equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Conforms to the UN Recommendations on the Transport of Dangerous Goods - Manual of Tests an... | |
| ISO 11058 Geosynthetics Vertical Penetration Resistance Analyzer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Used to determine the vertical permeability of geotextile and it... | |
| BSS 7365Flame Spread Tester for Thermal and Acoustic Insulation Materials | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Flame Spread Tester for Thermal and Acoustic Insulation Materials is designed to evalua... | |
| 16 CFR part 1633 flammability tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The tester is used as test fixture in the flammability test of solid and soft... | |
| Fabric and Sheet Large Bending Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheLarge Bending Tester accurately and quickly measures factors related to curvatures in sm... |
Похожие товары
| Battery Diaphragm Gas Permeability Tester ISO | Продавец: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Battery Diaphragm Gas Permea... | |
| Torsion Testing Tester ASTM, JIS, and DIN | Продавец: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Universal Torsion Testing Ma... | |
| Wire Torsion and Winding Tester ASTM and JIS | Продавец: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Wire Torsion and Winding Tes... | |
| Metal Wire Repeated Bending Tester ISO/DIS 7801 | Продавец: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Metal Wire Repeated Bending ... | |
| Metal Wire Wrap Tester ISO 4101 | Продавец: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Metal Wire Wrap Tester is de... |