Automatic voltage internal resistance tester
The Automatic Voltage & Internal Resistance Tester is a precision electrical testing instrument designed for rapid and accurate measurement of open-circuit voltage (OCV) and DC internal resistance of lithium-ion battery cells. The system is widely used in battery research laboratories, production lines, and quality control departments to evaluate electrical consistency, detect defective cells, and support battery performance classification and safety assessment.
Application
(1) Open-circuit voltage (OCV) measurement of lithium-ion pouch cells, cylindrical cells, and coin cells.
(2) DC internal resistance measurement for cell grading and sorting.
(3) Incoming inspection of battery cells and semi-finished products.
(4) Quality control during cell production, formation, and aging processes.
(5) Electrical consistency evaluation for batch comparison and statistical analysis.
(6) Screening of abnormal cells with high internal resistance or voltage deviation.
(7) Laboratory research and process validation for battery development.
Standards
(1) IEC 62660-2 – Secondary Lithium-Ion Cells – Reliability and Abuse Testing (reference application).
(2) ASTM E83 – Verification of Linear Displacement Measuring Systems (instrument calibration reference).
(3) ISO 3611 – Verification of Linear Measuring Instruments (instrument calibration reference).
(4) RoHS – Restriction of Hazardous Substances Directive.
(5) CE Certification – Conformité Européenne.
Features
(1) Simultaneous measurement of voltage and internal resistance with high accuracy.
(2) Automated test sequence reduces operator influence and improves repeatability.
(3) Fast measurement suitable for production-line and batch testing.
(4) Wide compatibility with pouch, cylindrical, and coin-type battery cells.
(5) Stable contact design ensures reliable electrical connection.
(6) Built-in data storage and result classification functions.
(7) Digital communication interface for data export and system integration.
(8) Electrical safety protection with overload and short-circuit prevention.
Technical Parameters
| Parameter | Specification |
|---|---|
| Voltage Measurement Range | 0 – 10 V |
| Voltage Measurement Accuracy | ±0.05% F.S |
| Internal Resistance Range | 0.01 mΩ – 1,000 mΩ |
| Internal Resistance Accuracy | ±0.5% F.S |
| Measurement Method | DC pulse method |
| Measurement Time | ≤ 1 s per cell |
| Data Storage | ≥ 100,000 records |
| Communication Interface | USB / RS232 / Ethernet (optional) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 300 × 250 × 400 mm |
| Weight | 15 kg (net) / 18 kg (gross) |
Accessories
(1) Battery test fixture for pouch, cylindrical, and coin cells.
(2) Kelvin test leads and probe assemblies.
(3) Calibration resistor set for internal resistance verification.
(4) Data acquisition and analysis software.
(5) Power cables and grounding accessories.
(6) Operation and maintenance manual.
(7) Compliance and calibration certificates.
Test Procedure
(1) Power on the tester and allow system self-check.
(2) Perform calibration using certified voltage sources and standard resistors.
(3) Place the battery cell into the appropriate test fixture.
(4) Ensure correct polarity and stable electrical contact.
(5) Start the test sequence to measure voltage and internal resistance.
(6) Display, store, and export the test results as required.
Maintenance Information
(1) Keep test probes and fixtures clean to ensure stable contact resistance.
(2) Periodically verify measurement accuracy using standard resistors.
(3) Inspect cables and connectors for wear or damage.
(4) Avoid exposure to corrosive gases, electrolyte leakage, or high humidity.
(5) Store the instrument in a clean and temperature-controlled environment when not in use.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Compression Fatigue Testing Machine | Standard YY/T 0959-2014 (China): Specifies compression fatigue testing protocols for intervertebral fusion devices, including load ratios, frequen... | |
| Freeze Resistance Test Chamber | Features and Benefits 1. Mechanical refrigeration unit, adopts cascade refrigeration mode, high refrigeration efficiency and stable refrigeration.... | |
| Fiber Blend Ratio meter | Product Introduction: It is used to measure the resistance value with a certain density under a certain geometry, and then converts it into the sp... | |
| Contact Lens Oxygen Permeability Analyzer | Product Introduction: Contact lens oxygen permeability measuring instrument (polarography) is designed for soft and hard contact lenses (contact l... | |
| Closed - Space Tester for Aerosol Sprays | Product Description Conforms to UN Recommendations on the Transportation of Dangerous Goods - Manual of Tests and Criteria 31.5 Confined Space Ign... |
Похожие товары
| Thrust Bearing Rolling Friction and Wear Testing Machine | Продавец: Standard International Group (HK) Limited | Applicable Standards: ASTM D3702 ASTM G99 ASTM G77 ISO 18535 Product Advantages: Simulates ... | |
| Falling Sand Abrasion Test machine | Продавец: Standard International Group (HK) Limited | The sand abrasion tester is a specialized testing device used to evaluate the abrasion resistance... | |
| Conveyor Belt Drum Friction Testing Machine | Продавец: Standard International Group (HK) Limited | Main Purposes of Conveyor Belt Drum Friction Testing Machine The conveyor belt drum friction tes... | |
| Dry Sand Rubber Wheel Wear Tester | Продавец: Standard International Group (HK) Limited | The dry sand rubber wheel abrasion tester is mainly used to test the abrasion resistance of mater... | |
| Sliding Bearing Fatigue Testing Machine | Продавец: Standard International Group (HK) Limited | The sliding bearing fatigue testing machine is an important testing device, mainly used to evalua... |