The near-infrared spectroscopy analyzer for textile fiber components /
Все товары поставщика
Overview:
The near-infrared spectroscopy analyzer for textile fiber components is suitable for qualitative and quantitative detection of textiles. The equipment features non-destructive testing, high speed, resource conservation, environmental friendliness, and the ability to perform both qualitative and quantitative analyses.
Non-destructive: It uses near-infrared light to directly irradiate the sample in transmission or diffuse reflection mode. Near-infrared light has a certain penetration ability and is non-destructive to the sample.
High speed: It can achieve millisecond-level scanning of a single spectrum at the fastest, and in combination with near-infrared spectroscopy analysis models, it can realize qualitative identification and simultaneous analysis of multiple components.
Resource conservation: Without consumables, it realizes "zero-cost" detection. Meanwhile, it can analyze multiple component indicators simultaneously, significantly saving detection costs and reducing detection labor intensity.
Environmental friendly: It directly obtains near-infrared spectra representing the intrinsic quality of the sample without pre-treatment, avoiding the use of toxic, harmful, and highly corrosive chemical reagents and eliminating "secondary pollution".
Qualitative and quantitative analysis: Relying on chemometrically established qualitative and quantitative near-infrared spectroscopy analysis models for predictive analysis, it can simultaneously predict and analyze multiple property component indicators.
Technical Parameters:
Wavelength range: 1000 nm - 2500 nm
Resolution: Adjustable from 1 nm, 2 nm, 4 nm, 8 nm to 16 nm
Wavelength accuracy: ≤ 0.5 nm
Wavelength repeatability: ≤ 0.04 nm
Stray light: < 0.1%
Signal-to-noise ratio: 3000:1
Analysis time: 22 seconds
Detection indicators: Qualitative and quantitative analyses are completed simultaneously.
Spectroscopic principle: Acousto-optic tunable filter (AOTF). The spectrometer has no mechanical vibration components, ensuring the stability and reliability of the instrument's spectrum. It adopts a bottom-illumination optical path design with non-contact sample design. Automatic calibration is available without manual calibration.
Detector: InGaAs high-sensitivity indium gallium arsenide detector. Noise level < 5E - 5
Light source: A 5V, 5W light source design with a lifespan of > 10.000 hours. The light source is easy to replace without professional training.
Working mode: Bottom-illumination optical path design with non-contact sample design. Diffuse reflection detection mode.
Sample cup: Rotatable sample cup design, compatible with both powdered and whole samples.
Operation and software system: The instrument is built-in with a computer. It runs on the WIN7 operating system, with 4G memory and a 64G solid-state drive. It comes with a USB interface and a wireless network card, enabling all networking functions, data transmission and storage, self-diagnosis of the instrument's status, remote control, etc.
Data modeling and analysis software: The built-in computer includes market-standard chemometric modeling and analysis software. The modeling and data processing software are integrated, making operation simple. The software is upgraded for free for life. The software can fully control the hardware part, perform self-diagnosis, and promptly prompt fault status.
Instrument working environment requirements: Temperature range: 5°C - 35°C; Humidity range: 5% - 85%
Product dimensions: 280 * 220 * 210 mm (L * W * H)
Product weight: 6 kg
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Hydrostatic Head Test Machine | Standards: AATCC 127 Water Resistance: Hydrostatic Pressure Test ASTM F1670 Standard Test Method for Resistance of Materials Used in Protective ... | |
| Mask Flame Flammability Tester | introduction: The flame-retardant tester of medical mask is used to test the flame-retardant performance of the mask when it is accidentally conta... | |
| Safety Helmet High Temperature Pre-Treatment Chamber | Main Purpose It is mainly used for the extremely high - temperature pre - treatment of safety helmets. Compliance Standard GB/T2812-2019 Te... | |
| Wear Track Profilometer | Main uses: The probe type material surface abrasion measuring instrument is a kind of high precision measuring equipment, its main purpose is to a... | |
| Toyota Specialized Abrasion Tester | Standard JIS L 0849(Japanese Industrial Standard for Abrasion Resistance of Textiles) ISO 5470-2(Rubber- or Plastics-Coated Fabrics — Abras... |
Похожие товары
| Plastic Smoke Density Tester F313 | Продавец: Standard International Group (HK) Limited | The F313 Plastic Smoke Density Tester is a precision instrument designed to measure the specific ... | |
| Xenon Test Chamber | Продавец: Standard International Group (HK) Limited | Features and Benefits 1.The use of xenon arc lamp as a light source, can simulate the full sunli... | |
| Single Cable Vertical Flame Tester | Продавец: Qinsun Instruments Co., LTD | Introduction Single Cable Vertical Flame Tester is used for the vertical flame propagation of a ... | |
| Safety Helmet Flammability Tester | Продавец: Qinsun Instruments Co., LTD | Product Introduction: Safety hat flame retardant performance tester for safety hat flame retarda... | |
| Furniture flammability tester | Продавец: Qinsun Instruments Co., LTD | Product details Furniture flammability tester is mainly used to test the combustion performance ... |