2-18 Zones Fire Alarm Control Panel for Conventional Fire Alarm System

External (key-switch operated):
Reset/resound/test zone lamps evacuate
Silence alarm sounders
Silence fault sounders

Internal:
One man detector test
Zone isolate
Revert to short-circuit: fire (no resistors in call points)

External indicators:
Sounder fault
Battery/power supply fault
Mains on
Zone fire
Zone fault

Internal indicators:
Open circuit zone fault
Short circuit zone fault
Zone isolated
Engineer test selected

Outputs:
Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)
Ancillary connections for expansion modules will allow the following:
Repeater panels
Multiple sounder outputs
Connection to landlord panel


Отправить запрос, связаться с поставщиком

Кому: Shenzhen Usafe Intelligent Technology Co., Ltd
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Network Natural Gas Alarm, Home Use Kitchen Gas Alarm
Network Natural Gas Alarm, Home Use Kitchen Gas Alarm Induced Gas: Natural Gas / LPG Input Voltage: DC 9-16V Operating Current: not more than60mA (DC12V) Alarm Current: 80-120mA (DC12V) Operating Humid...
Combined Smoke and Heat Detector, 2-Wire/3-Wire
Combined Smoke and Heat Detector, 2-Wire/3-Wire Input Voltage: DC10-35V Static Current: not more than50uA Alarm Current: 40-80mA Operating Humidity: 10%-95%RH Operating Temperature: -10 Celsius -...
2-10 Zones Conventional Fire Alarm Control Panel, FACP
2-10 Zones Conventional Fire Alarm Control Panel, FACP External (key-switch operated): Reset/resound/test zone lamps evacuate Silence alarm sounders Silence fault sounders Internal: One man detector te...
Conventional Photoelectric Smoke Detector, 2-wire/3-wire
Conventional Photoelectric Smoke Detector, 2-wire/3-wire Input Voltage: DC 12-35V Static Current: 15-30uA (DC 12-35V) Alarm Current: 30-50mA (DC 12-30V) Operating Humidity: 10%-95% RH Operating Temperatur...
4-Wire Optical Smoke Detector with Relay Output
4-Wire Optical Smoke Detector with Relay Output Input Voltage: DC 12-35V Static Current: not more than50uA (12-35V) Alarm Current: 40-80mA (12-30V) Operating Humidity: 10%-95% RH Operating Temper...
Все товары поставщика

Похожие товары

Сигнализация окиси углерода
Сигнализация окиси углерода Продавец: Shenzhen Sconda Intelligent Technology Co. Ltd Для бытовых сигнализаторов угарного газа с релейными выходами Расширенные возможности: Электрохи...
Сигнализация окиси углерода
Сигнализация окиси углерода Продавец: Shenzhen Sconda Intelligent Technology Co. Ltd Детекторы угарного газа имеют высокочувствительные датчики. Расширенные возможности: Электрохими...
Сигнализация окиси углерода
Сигнализация окиси углерода Продавец: Shenzhen Sconda Intelligent Technology Co. Ltd Детектор угарного газа с питанием от батареи AAA ЖК-дисплей в реальном времени Расширенные возмож...
Сигнализация окиси углерода
Сигнализация окиси углерода Продавец: Shenzhen Sconda Intelligent Technology Co. Ltd Детектор угарного газа для домашней безопасности соответствует сигнализации Co с питанием от бата...
Сигнализация окиси углерода
Сигнализация окиси углерода Продавец: Shenzhen Sconda Intelligent Technology Co. Ltd Детекторы сигнализации окиси углерода с батарейным питанием для внутренней домашней безопасности ...