2-18 Zones Fire Alarm Control Panel for Conventional Fire Alarm System

External (key-switch operated):
Reset/resound/test zone lamps evacuate
Silence alarm sounders
Silence fault sounders

Internal:
One man detector test
Zone isolate
Revert to short-circuit: fire (no resistors in call points)

External indicators:
Sounder fault
Battery/power supply fault
Mains on
Zone fire
Zone fault

Internal indicators:
Open circuit zone fault
Short circuit zone fault
Zone isolated
Engineer test selected

Outputs:
Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)
Ancillary connections for expansion modules will allow the following:
Repeater panels
Multiple sounder outputs
Connection to landlord panel



在线联系供应商

至: Shenzhen Usafe Intelligent Technology Co., Ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Combination Smoke & Heat Detector Alarm, 4-Wire with Relay Output
Combination Smoke & Heat Detector Alarm, 4-Wire with Relay Output Input Voltage: DC10-35V Static Current: not more than50uA Alarm Current: 40-80mA Operating Humidity: 10%-95%RH Operating Temperature: -10 Celsius -...
Standalone Smoke Detector with 9V Battery Operated
Standalone Smoke Detector with 9V Battery Operated Input Voltage: 9V battery (6F22) Static Current: not more than15uA Alarm Current: not more than15mA Operating Humidity: not more than95% RH Operati...
Conventional Optical Smoke Alarm with Remote LED Indicator
Conventional Optical Smoke Alarm with Remote LED Indicator Input Voltage: DC 12-35V Static Current: not more than50uA (DC 12-35V) Alarm Current: 40-80mA (DC 12-30V) Operating Humidity: 10%-95% RH Operating ...
Ceiling Mounted PIR Motion Sensor with 360° Detecting Angle
Ceiling Mounted PIR Motion Sensor with 360° Detecting Angle Input Voltage:DC9-16V Operating Current: not more than20mA (DC12V) Working Temperature:-10 Celsius- +55 Celsius Installation Method: Ceiling mounte...
Network Natural Gas Alarm, Home Use Kitchen Gas Alarm
Network Natural Gas Alarm, Home Use Kitchen Gas Alarm Induced Gas: Natural Gas / LPG Input Voltage: DC 9-16V Operating Current: not more than60mA (DC12V) Alarm Current: 80-120mA (DC12V) Operating Humid...
供应产品

Same products

Fire call point addressable fire alarm system emergency box
Fire call point addressable fire alarm system emergency box 卖方: Vedard Alarm Security Technology X X X
Газовый детектор с электромагнитным
Газовый детектор с электромагнитным 卖方: Vedard Alarm Security Technology X X
CO-детектор Углекислый оксид углерода Сигнализация переменного или постоянного тока Выход NC NO
CO-детектор Углекислый оксид углерода Сигнализация переменного или постоянного тока Выход NC NO 卖方: Vedard Alarm Security Technology Toxic gas detector and gas alarm of environment security sensor. CO303 AC power wire in or plug i...
Network Water Leak Detector with Tamper Switch
Network Water Leak Detector with Tamper Switch 卖方: Shenzhen Usafe Intelligent Technology Co., Ltd Input voltage: DC7-16V Operating Current: not more than15mA (DC12V) Alarm Current: not more than2...
Wired Curtain PIR Motion Detector, Curtain PIR Sensor
Wired Curtain PIR Motion Detector, Curtain PIR Sensor 卖方: Shenzhen Usafe Intelligent Technology Co., Ltd Input Voltage:DC9-16V Operating Current: not more than20mA (DC12V) Working Temperature:-10 Celsiu...