2-18 Zones Fire Alarm Control Panel for Conventional Fire Alarm System

External (key-switch operated):
Reset/resound/test zone lamps evacuate
Silence alarm sounders
Silence fault sounders

Internal:
One man detector test
Zone isolate
Revert to short-circuit: fire (no resistors in call points)

External indicators:
Sounder fault
Battery/power supply fault
Mains on
Zone fire
Zone fault

Internal indicators:
Open circuit zone fault
Short circuit zone fault
Zone isolated
Engineer test selected

Outputs:
Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)
Ancillary connections for expansion modules will allow the following:
Repeater panels
Multiple sounder outputs
Connection to landlord panel



Send product request

To: Shenzhen Usafe Intelligent Technology Co., Ltd
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

4-Wire Optical Smoke Detector with Relay Output
4-Wire Optical Smoke Detector with Relay Output Input Voltage: DC 12-35V Static Current: not more than50uA (12-35V) Alarm Current: 40-80mA (12-30V) Operating Humidity: 10%-95% RH Operating Temper...
Network Water Leak Detector with Tamper Switch
Network Water Leak Detector with Tamper Switch Input voltage: DC7-16V Operating Current: not more than15mA (DC12V) Alarm Current: not more than25mA Operating Temperature: -10 Celsius- +80 Celsiu...
Combination Smoke & Heat Detector Alarm, 4-Wire with Relay Output
Combination Smoke & Heat Detector Alarm, 4-Wire with Relay Output Input Voltage: DC10-35V Static Current: not more than50uA Alarm Current: 40-80mA Operating Humidity: 10%-95%RH Operating Temperature: -10 Celsius -...
Standalone Smoke Detector with 9V Battery Operated
Standalone Smoke Detector with 9V Battery Operated Input Voltage: 9V battery (6F22) Static Current: not more than15uA Alarm Current: not more than15mA Operating Humidity: not more than95% RH Operati...
Conventional Photoelectric Smoke Detector, 2-wire/3-wire
Conventional Photoelectric Smoke Detector, 2-wire/3-wire Input Voltage: DC 12-35V Static Current: 15-30uA (DC 12-35V) Alarm Current: 30-50mA (DC 12-30V) Operating Humidity: 10%-95% RH Operating Temperatur...
All supplier products

Same products

Fire call point addressable fire alarm system emergency box
Fire call point addressable fire alarm system emergency box Seller: Vedard Alarm Security Technology X X X
Gas detector with solenoid valve
Gas detector with solenoid valve Seller: Vedard Alarm Security Technology X X X X X X X X
CO detector Carbon Monoxide Alarm AC or DC power NC NO output
CO detector Carbon Monoxide Alarm AC or DC power NC NO output Seller: Vedard Alarm Security Technology Toxic gas detector and gas alarm of environment security sensor. CO303 AC power wire in or plug i...
Network Water Leak Detector with Tamper Switch
Network Water Leak Detector with Tamper Switch Seller: Shenzhen Usafe Intelligent Technology Co., Ltd Input voltage: DC7-16V Operating Current: not more than15mA (DC12V) Alarm Current: not more than2...
Wired Curtain PIR Motion Detector, Curtain PIR Sensor
Wired Curtain PIR Motion Detector, Curtain PIR Sensor Seller: Shenzhen Usafe Intelligent Technology Co., Ltd Input Voltage:DC9-16V Operating Current: not more than20mA (DC12V) Working Temperature:-10 Celsiu...