comparative tracking index tester
Application
Comparative tracking index testeris suitable for the research, production and quality inspection departments in the industry of lighting equipment, low-voltage electrical appliances, household appliances, machine tools, electrical machine, electric tools, electronic instruments, electro technical instruments, information technology equipment, as well as insulating materials , engineering plastics, electrical connectors, accessories industry.
Standards
GBT 4207.IEC 60112 (2003),IEC 60745-1.IEC 60335-1.IEC 60598-1.IEC 60884-1EC60112
Features
1.The chamber is paint spray procced, elegant and anti-corrosive, size:1200mm X 600mmx 1200mm.
2.All specimen holders are made by stainless steel material.
3.Equipment consists of the voltmeter, ammeter, delay overcurrent relay, power supply, circuit control system, button switch, signal lights and other components.
4.Automatic drip device contains drip tube, drip nozzle, counting device, drip counting device, drip control device, droplet volume measuring tool, etc.
5.Drip nozzle device can adjust; Adjust height 30 to 40 mm, ensure the drip position between the two electrodes .
6.Electrode device contains platinum electrode, electrode fixing device, 4 mm gauge, etc. The electrode is adjustable and detachable.
7.Electrode is 5 mm wide, 2 mm thick, 99.9% purity of platinum, 30 ~ 60 degrees sharp tip.
8.Electrode pressure to the sample can be adjusted. The adjusting range is 1.00 N (+ / - 0.001 N), electrode distance 4.0 mm + / - 0.01 mm, intersection Angle 60 ° + / - 5 ° .
9. Equipped with sample stage
10.Equipped with glass plate: thickness≥4mm
11. Equipped with electrolyte:1 bottle of ammonium chloride and 1 bottle of alkyl naphthalene sulfonic acid sodium reagent.
12.Test voltage: 0 ~ 1000 v adjustable and digital display. Maximum error of voltage meter display value is 1%.
13. Short circuit current: (1 ±0. 1), A voltage drop value less than 10% .
14.Test current over 0.5 A lasting more than 2 seconds, the system automatically shut down the equipment.
15.Safety door control system: when the door is opened, the test system will not work.
16.Electrode: 5 mm x 2 mm rectangle platinum electrode and brass electrode each one pair, in accordance with the size requirements of IEC60112 figure B. 1.
17.The intersection angle between electrodes is 60 °±5 °, spacing of 4±0.1 mm.
18.Electrode pressure to sample is 1. 00N±0.05N.
Specification
| Controller | Button control/ touch screen control |
| Voltage Display | Digitaldisplay |
| Current Display | Digitaldisplay |
| Dimensions | 1120 x 600 x 1020(L x W x H) |
| Inner Capacity | ≥0.5cube |
| ElectrodeMaterial | Pt |
| ElectrodeSize | 2mm x 5mm x 35 mm |
| ElectrodePressure | 1.00N |
| ElectrodeDistance | 4.0mm |
| Droplet Volume | 50 drop/1cm3 |
| Droplet Height | 35mm(can be set) |
| Droplet Time | 30s±0.1(can be set) |
Send product request
Other supplier products
| Shoelace wear tester | Main uses: Shoelace wear tester is mainly used to evaluate the durability and wear resistance of shoelaces. In the test, the LACES are usually fix... | |
| Wet leakage current test system of photovoltaic device | Standard IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval UL 61730: Safety Standard for Photovolta... | |
| Metal Wire Wrap Tester | According to the criteria: GB/T 2976 "Wire winding test method for Metal Materials" ISO 4101 Cold drawn steel wire for elevator wire ropes - Tech... | |
| Yellowing resistance test chamber | Applicable standards HG/T3986. ASTM D1748. etc. Scope of application Test method for determining the yellowing resistance of light and white pro... | |
| Strip Uniformity Testing Device (for Strip evenness tester) | Product Introduction: Cotton yarn fiber strip analyzer is a high performance, high test efficiency of textile laboratory instrument, it is used to... |
Same products
| Steaming Cylinder | Seller: Standard International Group (HK) Limited | Standards ISO 3005. BS 4323. NEXT TM 15. M&S P8. IWTO 29-76 Applications: Used for steamin... | |
| Drill Flocking Performance Tester丨Drill Flocking Performance Test mechine | Seller: Standard International Group (HK) Limited | Standards GB/T 12705.1/14272. BS EN 12132-1 Applications To determine the ability of penetrati... | |
| Wrinkle Recovery Tester 丨Wrinkle Recovery Test mechine | Seller: Standard International Group (HK) Limited | Standards AATCC 128, ISO 9867, ENKA 3061 Applications AATCC Wrinkle Recovery Tester is used to... | |
| Button Impact Tester丨Button Impact Test mechine | Seller: Standard International Group (HK) Limited | Standards ASTM D5171 Applications Button Impact Tester is used to determine the impact resista... | |
| AATCC Viewing Board丨AATCC Viewing Board tester | Seller: Standard International Group (HK) Limited | Standards Built to American Association of Textile Chemists and Colorist (AATCC) approved test m... |