comparative tracking index tester

Application

Comparative tracking index testeris suitable for the research, production and quality inspection departments in the industry of lighting equipment, low-voltage electrical appliances, household appliances, machine tools, electrical machine, electric tools, electronic instruments, electro technical instruments, information technology equipment, as well as insulating materials , engineering plastics, electrical connectors, accessories industry.

Standards

GBT 4207.IEC 60112 (2003),IEC 60745-1.IEC 60335-1.IEC 60598-1.IEC 60884-1EC60112

Features

1.The chamber is paint spray procced, elegant and anti-corrosive, size:1200mm X 600mmx 1200mm.

2.All specimen holders are made by stainless steel material.

3.Equipment consists of the voltmeter, ammeter, delay overcurrent relay, power supply, circuit control system, button switch, signal lights and other components.

4.Automatic drip device contains drip tube, drip nozzle, counting device, drip counting device, drip control device, droplet volume measuring tool, etc.

5.Drip nozzle device can adjust; Adjust height 30 to 40 mm, ensure the drip position between the two electrodes .

6.Electrode device contains platinum electrode, electrode fixing device, 4 mm gauge, etc. The electrode is adjustable and detachable.

7.Electrode is 5 mm wide, 2 mm thick, 99.9% purity of platinum, 30 ~ 60 degrees sharp tip.

8.Electrode pressure to the sample can be adjusted. The adjusting range is 1.00 N (+ / - 0.001 N), electrode distance 4.0 mm + / - 0.01 mm, intersection Angle 60 ° + / - 5 ° .

9. Equipped with sample stage

10.Equipped with glass plate: thickness≥4mm

11. Equipped with electrolyte:1 bottle of ammonium chloride and 1 bottle of alkyl naphthalene sulfonic acid sodium reagent.

12.Test voltage: 0 ~ 1000 v adjustable and digital display. Maximum error of voltage meter display value is 1%.

13. Short circuit current: (1 ±0. 1), A voltage drop value less than 10% .

14.Test current over 0.5 A lasting more than 2 seconds, the system automatically shut down the equipment.

15.Safety door control system: when the door is opened, the test system will not work.

16.Electrode: 5 mm x 2 mm rectangle platinum electrode and brass electrode each one pair, in accordance with the size requirements of IEC60112 figure B. 1.

17.The intersection angle between electrodes is 60 °±5 °, spacing of 4±0.1 mm.

18.Electrode pressure to sample is 1. 00N±0.05N.

Specification

Controller Button control/ touch screen control
Voltage Display Digitaldisplay
Current Display Digitaldisplay
Dimensions 1120 x 600 x 1020(L x W x H)
Inner Capacity ≥0.5cube
ElectrodeMaterial Pt
ElectrodeSize 2mm x 5mm x 35 mm
ElectrodePressure 1.00N
ElectrodeDistance 4.0mm
Droplet Volume 50 drop/1cm3
Droplet Height 35mm(can be set)
Droplet Time 30s±0.1(can be set)


在线联系供应商

至: 上海千实精密仪器
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Four-door Two-cap Durable Test Stand
Four-door Two-cap Durable Test Stand Real door electric glass lifter and manual lift is used to finish the performance and durability test. White car body and real car (passenger car) ...
Button Impact tester
Button Impact tester Standards: ASTM D5171: Test Method for Abrasion Resistance of Inks and Coatings (referenced for impact-related durability assessments). Applicati...
Fiber ratio resistance tester
Fiber ratio resistance tester Product Introduction: It is used to measure the resistance value with a certain density under a certain geometry, and then converts it into the sp...
Medical Face Mask Differential Pressure Tester
Medical Face Mask Differential Pressure Tester Medical face mask differential pressure tester also called mask breathility tester is to determine the breathability of medical face mask materials...
Fabric thickness
Fabric thickness Fabric thickness tester mainly used to measure the thickness of the fabric, suitable for leather, rubber and textiles and other materials, the thic...
供应产品

Same products

Steaming Cylinder
Steaming Cylinder 卖方: Standard International Group (HK) Limited Standards ISO 3005. BS 4323. NEXT TM 15. M&S P8. IWTO 29-76 Applications: Used for steamin...
Drill Flocking Performance Tester丨Drill Flocking Performance Test mechine
Drill Flocking Performance Tester丨Drill Flocking Performance Test mechine 卖方: Standard International Group (HK) Limited Standards GB/T 12705.1/14272. BS EN 12132-1 Applications To determine the ability of penetrati...
Wrinkle Recovery Tester 丨Wrinkle Recovery Test mechine
Wrinkle Recovery Tester 丨Wrinkle Recovery Test mechine 卖方: Standard International Group (HK) Limited Standards AATCC 128, ISO 9867, ENKA 3061 Applications AATCC Wrinkle Recovery Tester is used to...
Button Impact Tester丨Button Impact Test mechine
Button Impact Tester丨Button Impact Test mechine 卖方: Standard International Group (HK) Limited Standards ASTM D5171 Applications Button Impact Tester is used to determine the impact resista...
AATCC Viewing Board丨AATCC Viewing Board tester
AATCC Viewing Board丨AATCC Viewing Board tester 卖方: Standard International Group (HK) Limited Standards Built to American Association of Textile Chemists and Colorist (AATCC) approved test m...