G506 Mask Automatic Filter Performance Tester,CE certified mask filtration tester

The latest G506 mask automatic filter performance tester uses the most advanced technology and design concepts, to meet a variety of test standards and the latest National standard GB / T 32610.Only relatively little operation is required tocomplete all the function and operation. Hardware performance of G506 mask automatic filter performance tester is stable and excellent in repeatability. Software design meet with people's thinking mode, the interface is user-friendly, and the functional and parameter settings are very reasonable. It is convenient to userforacademic research and product development.

Application

G506 Mask Automatic Filter Performance Tester is used fortestingprofessional filter material and filtration efficiencyof a wide range of air filters including HEPA and ULPA filter, respirator, filter cartridge and protective clothing test. It also can use salt or oil mist to test filter media. Rapid acquisition of filter media performance evaluation parameters, and accurate evaluation of filter material quality, performance, life and so on. It is convenientto userforacademic research and product developmentof new filter materials, product quality control, material performance verification.

Standards

ASTM F2100:Standard Specification for Performance of Materials Used in Medical Face Masks

EN149:Respiratory protective devices - Filtering half masks to protect against particles - Requirements, testing, marking

NIOSH-42 CFR84:NIOSH Guide to the Selection and Use of Particulate Respirators(或 42 CFR Part 84 - Approval of Respiratory Protective Devices)

Feature

Complies to more standards than any other filter tester

Salt and oil testing in one unit

Highly consistent test results

New user-interface and data recording options

Customizable fully automated testing sequences

Ergonomic design

Reduced cost of ownership with new serviceable photometers

Worldwide service and support

Parameters

Items Parameter
Apllication Load and quality control
Max Efficiency 99.999%
Aerosol Type DOP/PAO/DEHS/Paraffi/Others Oil Aerosol、Salt
Aerosol Generation Atomizing
CMD 0.2μm(Oil)or 0.75um(NaCl)
GSD <1.6(Oil)or <1.86(NaCl)
Flow Rate 15-100L/min
Resistance 0-150mm H2O(0-1470Pa)
Particle Detect Scatter Photometer
Measurement Time 10 Sec.
Data Report LCD,RS-232
Operation Independent tewster、automatic production line
Standard compliant US 42 CFR part 84.EN 143.JMOL,ISO 23328-1 ISO 16900-3
Power Supply 115VAC、60Hz,10A或230VAC,50Hz,5A
Compressor Air 80psig,7scfm(550kPa,198std.L/min)
Dimension 70cm x 70cm x 147cm(28in, x 28in.x 58in.)

Accessoriess

Main Unit: As the core component of the testing instrument, it is responsible for overall control and data processing.

Aerosol Generator: Includes salt particulate aerosol generators and oil particulate aerosol generators, used to generate the aerosol particles required for the test.

Classifier: Utilizes the principle of inertia to collect unwanted large particles into a collection bottle, ensuring that the aerosol particles entering the testing system meet the requirements.

Particle Counter: Usually equipped with two units, used to measure the number or mass concentration of aerosols upstream and downstream of the filter media, and is a key device for calculating filtration efficiency. Some systems may use a laser scattering photometer instead of a particle counter.

Static Neutralization Device: Neutralizes the static electricity carried by the aerosols, reducing particle loss and the influence of static electricity on the test results.

Differential Pressure Sensor: Monitors the pressure drop across the filter media, assessing changes in resistance during the filtration process.

Flow Meter: Monitors the flow rate during the test, ensuring consistency of test conditions. Flow meters are typically 2.5 grade accurate, ranging from 10-100 L/min.

Vacuum pump: Provides the necessary negative pressure environment to ensure aerosol particles can smoothly enter the testing system.

Pneumatic clamps and protective devices: Employ pneumatic clamping, offering convenient operation and high safety, while also featuring protective devices to ensure safe use.

Programmable logic controller (PLC) and touchscreen: Enables automated control of the testing process, including control, monitoring, calculation, and data display functions. Some devices utilize a PLC control system and are equipped with a 7-inch color touchscreen.

Instruction manual and power cord: Provides an operation guide and power connection instructions to ensure users can correctly operate the equipment.

Test Procedures

Operating Procedures:

First: Prepare the accessories and test sample;

Turn on the instrument and enter the LCD screen operating interface;

Perform a no-load test first;

Press the dual-control pneumatic keys on both sides to lower the clamp;

Set the airflow rate and aerosol particle parameters;

After the data stabilizes, proceed to the next step;

Obtain the amount of aerosol upstream of the filter media;

Once the data stabilizes, a "Place Clamp" dialog box will pop up on the screen;

Place the prepared sample into the instrument clamp and clamp it securely;

Start the test;

Wait a few seconds to obtain the amount of aerosol downstream of the filter media and calculate the filtration efficiency;

The instrument will automatically print out the test report;

Remove the sample;

After the test, turn off the instrument and evaluate the filtration performance of the material based on the test data results.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Laser Compression Testing Equipment
Laser Compression Testing Equipment The Laser Compression Deformation Tester for sealing strips is designed for automotive sealing strips to precisely measure compression deformation ...
Whole shoe breathability and heat preservation testing machine
Whole shoe breathability and heat preservation testing machine Standard SATRA TM376: Thermal insulation testing of footwear with sock integration. SATRA TM386: Water vapor permeability assessment for athlet...
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developing hydrophobic coatings for medical textiles Qual...
PV Hail Impact Tester
PV Hail Impact Tester Standard Compliance IEC 61215: Mechanical load testing for terrestrial photovoltaic modules. UL 61730: Safety standards for photovoltaic modules ...
Bearing Friction Torque Measuring Instrument
Bearing Friction Torque Measuring Instrument Bearing friction torque is an important factor affecting bearing noise, vibration, and lifespan, and is a key indicator for measuring the dynamic p...
供应产品

Same products

Common Rail Control Valve Assembly F00ZC01307
Common Rail Control Valve Assembly F00ZC01307 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Common Rail ...
Fuel Injector Control Valve Set F00RJ01479
Fuel Injector Control Valve Set F00RJ01479 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecto...
Fuel Injector Valve Set F00RJ02213
Fuel Injector Valve Set F00RJ02213 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecto...
Common Rail Injector Valve Set F00RJ00339
Common Rail Injector Valve Set F00RJ00339 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Common Rail ...
Fuel Injection Pump  for Yanmar Wb93r Wb97r Wb97s Wb98a
Fuel Injection Pump for Yanmar Wb93r Wb97r Wb97s Wb98a 卖方: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecti...