Biomedical fatigue simulator for implants
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Tibial Tray Fatigue Testing Machine is a specialized device designed to evaluate the long-term mechanical durability of tibial implant components used in knee prostheses. It simulates repetitive loading conditions that occur during human walking or physical activity, applying cyclic forces to the tibial tray to assess fatigue resistance, structural integrity, and potential deformation over time. This testing ensures that implants can withstand real-life stress without failure, supporting quality control, product development, and compliance with orthopedic implant standards such as ISO 14879.
Standard
(1)YY/T 0810 (China): Specifies fatigue testing protocols for tibial trays in total knee arthroplasty, focusing on support and protection of plastic bearing surfaces.
(2)ASTM F1800 (International): Defines methodologies for evaluating the fatigue strength of tibial components under cantilever loading conditions.
(3)ISO 14879-1: Additional compliance for general fatigue testing of total knee joint prostheses.
Product Advantages
(1)Cantilever Loading Precision: Advanced actuator design ensures uniform stress distribution per ASTM F1800 requirements.
(2)5 Million Cycle Endurance: Proven capability to complete YY/T 0810’s 5×10⁶-cycle fatigue test without calibration drift.
(3)Dynamic Load Control: Closed-loop system maintains R=0.1 stress ratio during sinusoidal/random loading (0.1–10 Hz).
(4)Real-Time Fracture Detection: AI-powered acoustic emission monitoring identifies micro-cracks at sub-millisecond intervals.
(5)Intuitive Workflow: 21.5” capacitive touchscreen with gesture control and pre-loaded SOPs for 10+ implant geometries.
(6)Modular Environmental Chambers: Quick-swap pods for simulated physiological (-20°C to +50°C) and corrosive environment testing.
Product Features
(1)Electromagnetic Actuator: 3.000 N peak force capacity with programmable load ratios (R=0.1–10).
(2)Cantilever Loading System: Simulates physiological knee joint moments with ±20 mm axial displacement.
(3)Dynamic Load Control: 0.1–10 Hz frequency range with programmable waveforms (sine, square, random, custom).
(4)Thermal-Mechanical Chamber: ±0.3°C temperature stability with integrated humidity control (10–95% RH).
(5)High-Speed Imaging Ready: Syncs with external cameras for full-field strain mapping (DIC optional upgrade).
(6)Safety First: Triple-redundant emergency stop, overload clutches, and laser-based specimen breakage detection.
Accessories
(1)Tibial Tray Test Fixture Kit:
Self-centering collet system (28–40 mm tibial tray compatibility)
Laser-aligned loading anvils with diamond-like carbon (DLC) coating
(2)Thermal-Mechanical Chamber:
15L capacity with rapid cooling/heating (15°C/min)
316L stainless steel interior with HEPA filtration
(3)TestMaster Ultimate Software:
Automated S-N curve generation and fatigue limit calculation
21 CFR Part 11-compliant audit trail with blockchain timestamping
Remote monitoring via dedicated iOS/Android app
(4)Operator Kit:
Calibrated torque wrench set (0.5–50 Nm)
Specimen alignment gauges (ASTM F1800 compliant)
(5)Calibration Bundle:
NIST-traceable force calibration weights
Temperature/humidity verification probe
(6)Safety Kit:
Laser safety curtains
Acoustic enclosure with 30 dB noise reduction
Technical Parameters
| Parameter | Specification |
|---|---|
| Max. Dynamic Force | ±3.000 N (6.000 N peak optional) |
| Frequency Range | 0.1–10 Hz (0.01 Hz increments) |
| Load Ratio (R) | 0.1–10 (adjustable) |
| Axial Displacement | ±20 mm (0.1 μm resolution) |
| Torque Capacity | ±20 Nm (0.01 Nm resolution) |
| Temperature Range | -20°C to +50°C (environmental chamber) |
| Humidity Control | 10–95% RH (non-condensing) |
| Data Sampling Rate | 100 kHz (synchronized across 16 channels) |
| Power Requirements | 220V/110V ±10%, 50/60Hz, 2.000W |
| Dimensions (W×D×H) | 1.500 × 1.000 × 2.000 mm |
| Weight | 750 kg (including environmental chamber) |
| Noise Level | <65 dB (A-weighted) |
在线联系供应商
Other supplier products
| Vehicle shock absorber jounce testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards QC/T 740-2017 – Automotive Seat Assembly Fatigue Test Standard SAE J826-2... | |
| Incline Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM D7748: Impact resistance testing of packaging and transport systems. ISO ... | |
| Torsional Fatigue Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0857-2011 (China): Specifies torsional fatigue testing protocols for spinal ... | |
| UV Lamp Aging Test Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard JTG E50 T1164: Testing methods for geosynthetics in highway engineering. GB/T 14... | |
| Catheter Burst Pressure Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Burst Pressure Tester uses the positive pressure method and is designed accord... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |