QT - CB02 Solar energy automatic insect pest inspection lamp

Features:
LED displays air temperature and humidity, pointer shows instrument voltage and current;
The production and inspection in line with the GB/T 24689.1-2009 plant protection machinery standards;
Use optical, electric, and numerical control technologies, compatible with ATCSP plant diseases and pests inspection and prevention system;
Auto-on in the daytime and auto-off at night. Nighttime working status is not affected by instantaneous intense light ;
Use far-infrared light to process pest bodies rapidly (no poison bottle);
Insect chamber has an auto rotation system with gear drive, which ensures separate insect samples collected in 8 different time periods;
Rain control device can automatically manipulate the work of the whole lamp according to rainfall change;
Drainage device can effectively separate the insects from the rain;
Lamp functions include optical and rain control, far-infrared insect body treatment, daily insect body storage, LED displays air temperature and humidity;
Operation modes include power saving mode, regular mode, high-efficient mode, users can choose the appropriate operation mode according to the actual situation to achieve the balance between insect capture and power saving.
QT - CB02 Solar energy automatic insect pest inspection lamp
Technical parameters:
Light trap
20 w black light lamp (main wavelength 365 nm)
Lamp body material
GB32080-92 stainless steel structure,
in accordance with GB/T4237
Lamp support material
GB3280-80 stainless steel
Lamp dimension
650 mm×650 mm×1900 mm
Power supply
DC 24 V; 24 V 100 W solar panels, 24 V 38 AH storage battery
Power consumption
Standby no more than 5 W, total power consumption no more than 300 W
Startup time
within 5 s
Temperature control of far-infrared insect pest chamber
85 ± 5 ℃ after 15 min of operation, processing time is adjustable (15 choices)
Insulation resistance
≥ 2.5 MΩ, with a leakage protection device
Far-infrared insect body treatment
The fatality rate is no less than 98%, integrality of insect body is no less than 95%
Hitting screen size
the two hitting screens are with an Angle of 120 degrees, 595 ± 2 mm long, 213 ± 2 mm wide, 5 mm thick
Design life
≥ 5 years
ORIGIN: CHINA
Other supplier products
|
|
Small diameter growth measuring instrument (DD-S) |
DD-S is specially used for diameter measurement of crops, small trees, shrubs and branches. Suitable for plants less than 5 cm in diameter. The uni... |
|
|
QT-SZZ Series Increment Borer |
Application: QT-SZZ series Increment Borer is a specialized tool to determine the age and the growth increment of a tree by exacting a section of w... |
|
|
Conductivity Sensor 70-WQ301 |
270-WQ301 conductivity sensor is a durable and reliable water conductivity measurement device. The conductivity sensor is cast on a 25-foot long ma... |
|
|
CS451/456 pressure water level sensor |
The CS451 water pressure sensor produced by the American Campbell company can provide accurate and reliable water pressure and water temperature da... |
|
|
SkyVUEPRO Ceilometer (formerly CS135) |
SkyVUEPRO Ceilometer can be used in meteorology and aviation to measure cloud height and vertical visibility. Using lidar (laser detection and rang... |
All supplier products
Same products