E-Stop Button, Safety Gate Safety Relay
CHENZHU e stop safety relayare suitable for the application of emergency Stop button and safety gate. Support 2 safety output contacts (N/O) and 2 auxiliary output contacts (N/C) or 3NO+1NC or 2NO+2NC or 2NO+1NC+3NO(t)+1NC(t).
Safety monitoring relays can be operated in single or double channel mode, manual or automatic reset, and with the function of monitoring the short circuit between channels.
Features & Advantages of E-Stop Button, Safety Gate Safety Relay
Support single or dual-channel
Support instantaneous or delayed output
Support manual or automatic reset
Short circuit monitoring
Parameter of E-Stop Button, Safety Gate Safety Relay
CZSR8001-3A1B |
CZSR8001-3A1B(M) |
CZSR8002-2A2AT |
CZSR8002-2A2AT(M) |
CZSR8003-3A1B |
CZSR8001-2A1B |
CZSR8001-2A1B3AT1BT |
|
Supply voltage |
24V DC/AC |
24V DC/AC |
24V DC |
24V DC |
100V~230V AC |
24V DC/AC |
24V DC/AC |
Voltage tolerance |
|||||||
Current consumption |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤130mA (24V DC) |
≤130mA (24V DC) |
≤7 VA (220V AC) |
≤90mA (24V DC) / ≤240mA (24V DC) |
≤170mA (24V DC) / ≤400mA (24V AC) |
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (220V AC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
Cable resistance |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
Input devices |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
Number of contacts |
3NO+1NC |
3NO+1NC |
2NO+2NO(t) |
2NO+2NO(t) |
3NO+1NC |
2NO+2NC |
2NO+1NC+3NO(t)+1NC(t) |
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 |
AgSnO2 |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 μm Au |
AgSnO2 + 0.2 μm Au |
External contact fuse protection |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO) |
10A gL/gG NEOZED (NO) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C) |
10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C) |
Mechanical endurance of contacts |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
Utilisation category |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V |
In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
Switch-on delay |
≤300ms |
≤150ms |
≤300ms |
≤150ms |
≤300ms |
≤300ms |
≤300ms |
Delay-on de-energisation |
≤30ms |
≤30ms |
≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s) |
≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s) |
≤30ms |
≤30ms (instantaneous);- |
≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(delayed, factory set as 5s) |
Recovery time |
≤100ms |
≤100ms |
≤100ms |
≤100ms |
≤500ms |
≤100ms |
≤100ms |
Supply short interruption |
20ms |
20ms |
20ms |
20ms |
20ms |
20ms |
20ms |
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
Vibration |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
Relative humidity |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
Elevation |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
Overvoltage category |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅱ |
Ⅱ |
Ⅱ |
Pollution degree |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
Rated insulation voltage |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
4000V (1.2/50us) |
4000V (1.2/50us) |
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
Safety integrity level |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
Performance level |
PLe |
PLe |
PLe |
PLe |
PLe |
PLe |
PLe |
Category |
Block Diagram of E-Stop Button, Safety Gate Safety Relay
Typical Applications of E-Stop Button, Safety Gate Safety Relay
Chenzhumanufactures the most reliable interface product for safety automation system. We are here to help your device run more safely. Here you can not only get world-class products, but also outstanding service for safety and automation system.
Send product request
Other supplier products
Photovoltaic 1000 DC Power SPD | Photovoltaic DCSPD1000 Signal SPDfor DC power, 1000VDC; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features &am... | |
A Brief Introduction of Intrinsically Safe Barrier | Intrinsically safety barriers in instrumentationimproves workplace safety by limiting the energy available in the process. Ⅰ. What is intrinsica... | |
Safety Relay | SHANGHAI CHENZHU INSTRUMENT CO., LTD. is a very established provider that specialises in safety and automation system. We have over 24 years of exp... | |
Safety Relay | Automation automation direct safety relays are mainly applied to the safety control circuit, connecting the safety sensing elements and mechanical ... | |
GS8500-EX Temperature Converter Intrinsic Safety Barrier | Temperature input isolated barriers, converter potentiometer/RTD/TC signals in hazardous area into 0/4~20mA or 0/1~5V signals and output to safe ar... |
Same products
DM-16BF DM-18BF New cover Electric Sprayer | Seller: Zhejiang Huaqi Information Technology Co., LTD | The Electric Knapsack Sprayer is a game-changer in the field of agricultural pest control. Engine... | |
Simple Round Breeding Cage | Seller: Zhejiang Huaqi Information Technology Co., LTD | The Simple Round Breeding Cage features a durable and lightweight construction, making it suitabl... | |
Syria-liquid nitrogen container for cell storage-liquid nitrogen level gauge | Seller: Henan Tianzhidao Biological Technology Co., Ltd | Precise experimental conditions and safe sample storage are key elements for the smooth developme... | |
Italy-liquid nitrogen cell storage tank-liquid nitrogen tank level indicator | Seller: Henan Tianchi Instrument & Equipment Co., Ltd. | Precise experimental conditions and safe sample storage are key elements for the smooth developme... | |
Egypt-cryogenic cell storage-liquid nitrogen level monitors | Seller: Henan Tianzhidao Biological Technology Co., Ltd. | Precise experimental conditions and safe sample storage are key elements for the smooth developme... |