E-Stop Button, Safety Gate Safety Relay
CHENZHU e stop safety relayare suitable for the application of emergency Stop button and safety gate. Support 2 safety output contacts (N/O) and 2 auxiliary output contacts (N/C) or 3NO+1NC or 2NO+2NC or 2NO+1NC+3NO(t)+1NC(t).
Safety monitoring relays can be operated in single or double channel mode, manual or automatic reset, and with the function of monitoring the short circuit between channels.
Features & Advantages of E-Stop Button, Safety Gate Safety Relay
Support single or dual-channel
Support instantaneous or delayed output
Support manual or automatic reset
Short circuit monitoring
Parameter of E-Stop Button, Safety Gate Safety Relay
|
CZSR8001-3A1B |
CZSR8001-3A1B(M) |
CZSR8002-2A2AT |
CZSR8002-2A2AT(M) |
CZSR8003-3A1B |
CZSR8001-2A1B |
CZSR8001-2A1B3AT1BT |
|
|
Supply voltage |
24V DC/AC |
24V DC/AC |
24V DC |
24V DC |
100V~230V AC |
24V DC/AC |
24V DC/AC |
|
Voltage tolerance |
|||||||
|
Current consumption |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤130mA (24V DC) |
≤130mA (24V DC) |
≤7 VA (220V AC) |
≤90mA (24V DC) / ≤240mA (24V DC) |
≤170mA (24V DC) / ≤400mA (24V AC) |
|
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (220V AC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
|
Cable resistance |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
|
Input devices |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
|
Number of contacts |
3NO+1NC |
3NO+1NC |
2NO+2NO(t) |
2NO+2NO(t) |
3NO+1NC |
2NO+2NC |
2NO+1NC+3NO(t)+1NC(t) |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 |
AgSnO2 |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 μm Au |
AgSnO2 + 0.2 μm Au |
|
External contact fuse protection |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO) |
10A gL/gG NEOZED (NO) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C) |
10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
|
Utilisation category |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V |
In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤150ms |
≤300ms |
≤150ms |
≤300ms |
≤300ms |
≤300ms |
|
Delay-on de-energisation |
≤30ms |
≤30ms |
≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s) |
≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s) |
≤30ms |
≤30ms (instantaneous);- |
≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(delayed, factory set as 5s) |
|
Recovery time |
≤100ms |
≤100ms |
≤100ms |
≤100ms |
≤500ms |
≤100ms |
≤100ms |
|
Supply short interruption |
20ms |
20ms |
20ms |
20ms |
20ms |
20ms |
20ms |
|
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
|
Vibration |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
|
Relative humidity |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
|
Elevation |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
|
Overvoltage category |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅱ |
Ⅱ |
Ⅱ |
|
Pollution degree |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|
Rated insulation voltage |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
|
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
4000V (1.2/50us) |
4000V (1.2/50us) |
|
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
|
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
|
Safety integrity level |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
|
Performance level |
PLe |
PLe |
PLe |
PLe |
PLe |
PLe |
PLe |
|
Category |
Block Diagram of E-Stop Button, Safety Gate Safety Relay
Typical Applications of E-Stop Button, Safety Gate Safety Relay
Chenzhumanufactures the most reliable interface product for safety automation system. We are here to help your device run more safely. Here you can not only get world-class products, but also outstanding service for safety and automation system.
Send product request
Other supplier products
| Temperature Transmitter | SHANGHAI CHENZHU INSTRUMENT CO., LTD. is a very established provider that specialises in automation and safety. We have over 24 years of experience... | |
| AC Power SPD | The surge protector is designed to prevent transient surge conditions. Large single surge events, such as lightning, can reach hundreds of thousand... | |
| Signal Conditioner | Signal Conditioner Universal signal conditioner is used in industrial process control systems. Isolated signal conditionerconnects industrial fiel... | |
| CZ3000 Temperature Converter Signal Conditioner | Thermal resistance type isolator, the two-wire or three-wire system resistance signal is converted into 0/4~20mA current signal isolation or 0/1~5V... | |
| Antennas And Feeders SPD | Antennas feeders SPD is used in the antenna feeder circuit of the radio communication station to suppress the induced lightning waves from the ante... |
Same products
| FT wax used for EVA-based hot melt adhesive | Seller: Syntop chemical Co.,Ltd. | Fischer-Tropsch wax is a commonly used performance modifier in hot melt adhesives, especially for... | |
| high melting point FT wax improve the heat resistance of adhesives | Seller: Syntop chemical Co.,Ltd. | FischerTropsch wax is an alkane polymer produced from synthesis gas or natural gas via the Fische... | |
| For hot melt adhesive high melting point FT WAX | Seller: Syntop chemical Co.,Ltd. | The key advantage of high-melting-point Fischer-Tropsch wax in hot-melt adhesives stems from its ... | |
| Diesel Injection Delivery Valve 1W6982 Diesel Injection Delivery Valve 19A | Seller: China lutong | Diesel Injection Delivery Valve 1W6982 Diesel Injection Delivery Valve 19AChris Diesel Injection... | |
| High melting point FT wax used as plastic processing additives | Seller: Syntop chemical Co.,Ltd. | Due to its high purity, low oil content, narrow melting range, high hardness, and excellent therm... |