E-Stop Button, Safety Gate Safety Relay

CHENZHU e stop safety relayare suitable for the application of emergency Stop button and safety gate. Support 2 safety output contacts (N/O) and 2 auxiliary output contacts (N/C) or 3NO+1NC or 2NO+2NC or 2NO+1NC+3NO(t)+1NC(t).

Safety monitoring relays can be operated in single or double channel mode, manual or automatic reset, and with the function of monitoring the short circuit between channels.

Features & Advantages of E-Stop Button, Safety Gate Safety Relay

Support single or dual-channel

Support instantaneous or delayed output

Support manual or automatic reset

Short circuit monitoring

Parameter of E-Stop Button, Safety Gate Safety Relay

CZSR8001-3A1B

CZSR8001-3A1B(M)

CZSR8002-2A2AT

CZSR8002-2A2AT(M)

CZSR8003-3A1B

CZSR8001-2A1B

CZSR8001-2A1B3AT1BT

Supply voltage

24V DC/AC

24V DC/AC

24V DC

24V DC

100V~230V AC

24V DC/AC

24V DC/AC

Voltage tolerance

Current consumption

≤90mA (24V DC) / ≤240mA (24V AC)

≤90mA (24V DC) / ≤240mA (24V AC)

≤130mA (24V DC)

≤130mA (24V DC)

≤7 VA (220V AC)

≤90mA (24V DC) / ≤240mA (24V DC)

≤170mA (24V DC) / ≤400mA (24V AC)

Input current

≤50mA (24V DC)

≤50mA (24V DC)

≤50mA (24V DC)

≤50mA (24V DC)

≤50mA (220V AC)

≤50mA (24V DC)

≤50mA (24V DC)

Cable resistance

≤15Ω

≤15Ω

≤15Ω

≤15Ω

≤15Ω

≤15Ω

≤15Ω

Input devices

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

E-stop buttons, Safety gates

Number of contacts

3NO+1NC

3NO+1NC

2NO+2NO(t)

2NO+2NO(t)

3NO+1NC

2NO+2NC

2NO+1NC+3NO(t)+1NC(t)

Contact material

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 µm Au

AgSnO2

AgSnO2

AgSnO2 + 0.2 µm Au

AgSnO2 + 0.2 μm Au

AgSnO2 + 0.2 μm Au

External contact fuse protection

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (NO)

10A gL/gG NEOZED (NO)

10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC)

10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C)

10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C)

Mechanical endurance of contacts

≥107

≥107

≥107

≥107

≥107

≥107

≥107

Utilisation category

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V

In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V

Switch-on delay

≤300ms

≤150ms

≤300ms

≤150ms

≤300ms

≤300ms

≤300ms

Delay-on de-energisation

≤30ms

≤30ms

≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s)

≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s)

≤30ms

≤30ms (instantaneous);-

≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(delayed, factory set as 5s)

Recovery time

≤100ms

≤100ms

≤100ms

≤100ms

≤500ms

≤100ms

≤100ms

Supply short interruption

20ms

20ms

20ms

20ms

20ms

20ms

20ms

EMC

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

EN60947, EN61000-6-2, EN61000-6-4

Vibration

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm

Ambient temperature

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

-20℃~+60℃

Storage temperature

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

Relative humidity

10%~90%

10%~90%

10%~90%

10%~90%

10%~90%

10%~90%

10%~90%

Elevation

≤2000m

≤2000m

≤2000m

≤2000m

≤2000m

≤2000m

≤2000m

Overvoltage category

Pollution degree

2

2

2

2

2

2

2

Rated insulation voltage

250V AC

250V AC

250V AC

250V AC

250V AC

250V AC

250V AC

Rated impulse voltage

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

6000V (1.2/50us)

4000V (1.2/50us)

4000V (1.2/50us)

Dielectric strength

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

1500V AC, 1min

Clearance and creepage distance

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

In accordance with EN 60947-1

Safety integrity level

SIL3

SIL3

SIL3

SIL3

SIL3

SIL3

SIL3

Performance level

PLe

PLe

PLe

PLe

PLe

PLe

PLe

Category

Block Diagram of E-Stop Button, Safety Gate Safety Relay

Typical Applications of E-Stop Button, Safety Gate Safety Relay

Chenzhumanufactures the most reliable interface product for safety automation system. We are here to help your device run more safely. Here you can not only get world-class products, but also outstanding service for safety and automation system.


Send product request

To: Shanghai Chenzhu Instrument Co., Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Temperature Transmitter
Temperature Transmitter SHANGHAI CHENZHU INSTRUMENT CO., LTD. is a very established provider that specialises in automation and safety. We have over 24 years of experience...
AC Power SPD
AC Power SPD The surge protector is designed to prevent transient surge conditions. Large single surge events, such as lightning, can reach hundreds of thousand...
Signal Conditioner
Signal Conditioner Signal Conditioner Universal signal conditioner is used in industrial process control systems. Isolated signal conditionerconnects industrial fiel...
CZ3000 Temperature Converter Signal Conditioner
CZ3000 Temperature Converter Signal Conditioner Thermal resistance type isolator, the two-wire or three-wire system resistance signal is converted into 0/4~20mA current signal isolation or 0/1~5V...
Antennas And Feeders SPD
Antennas And Feeders SPD Antennas feeders SPD is used in the antenna feeder circuit of the radio communication station to suppress the induced lightning waves from the ante...
All supplier products

Same products

FT wax used for EVA-based hot melt adhesive
FT wax used for EVA-based hot melt adhesive Seller: Syntop chemical Co.,Ltd. Fischer-Tropsch wax is a commonly used performance modifier in hot melt adhesives, especially for...
high melting point FT wax improve the heat resistance of adhesives
high melting point FT wax improve the heat resistance of adhesives Seller: Syntop chemical Co.,Ltd. FischerTropsch wax is an alkane polymer produced from synthesis gas or natural gas via the Fische...
For hot melt adhesive high melting point FT WAX
For hot melt adhesive high melting point FT WAX Seller: Syntop chemical Co.,Ltd. The key advantage of high-melting-point Fischer-Tropsch wax in hot-melt adhesives stems from its ...
Diesel Injection Delivery Valve 1W6982 Diesel Injection Delivery Valve 19A
Diesel Injection Delivery Valve 1W6982 Diesel Injection Delivery Valve 19A Seller: China lutong Diesel Injection Delivery Valve 1W6982 Diesel Injection Delivery Valve 19AChris Diesel Injection...
High melting point FT wax used as plastic processing additives
High melting point FT wax used as plastic processing additives Seller: Syntop chemical Co.,Ltd. Due to its high purity, low oil content, narrow melting range, high hardness, and excellent therm...