E-Stop Button, Safety Gate Safety Relay
CHENZHU e stop safety relayare suitable for the application of emergency Stop button and safety gate. Support 2 safety output contacts (N/O) and 2 auxiliary output contacts (N/C) or 3NO+1NC or 2NO+2NC or 2NO+1NC+3NO(t)+1NC(t).
Safety monitoring relays can be operated in single or double channel mode, manual or automatic reset, and with the function of monitoring the short circuit between channels.
Features & Advantages of E-Stop Button, Safety Gate Safety Relay
Support single or dual-channel
Support instantaneous or delayed output
Support manual or automatic reset
Short circuit monitoring
Parameter of E-Stop Button, Safety Gate Safety Relay
|
CZSR8001-3A1B |
CZSR8001-3A1B(M) |
CZSR8002-2A2AT |
CZSR8002-2A2AT(M) |
CZSR8003-3A1B |
CZSR8001-2A1B |
CZSR8001-2A1B3AT1BT |
|
|
Supply voltage |
24V DC/AC |
24V DC/AC |
24V DC |
24V DC |
100V~230V AC |
24V DC/AC |
24V DC/AC |
|
Voltage tolerance |
|||||||
|
Current consumption |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤130mA (24V DC) |
≤130mA (24V DC) |
≤7 VA (220V AC) |
≤90mA (24V DC) / ≤240mA (24V DC) |
≤170mA (24V DC) / ≤400mA (24V AC) |
|
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (220V AC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
|
Cable resistance |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
|
Input devices |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
|
Number of contacts |
3NO+1NC |
3NO+1NC |
2NO+2NO(t) |
2NO+2NO(t) |
3NO+1NC |
2NO+2NC |
2NO+1NC+3NO(t)+1NC(t) |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 |
AgSnO2 |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 μm Au |
AgSnO2 + 0.2 μm Au |
|
External contact fuse protection |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO) |
10A gL/gG NEOZED (NO) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C) |
10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
|
Utilisation category |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V |
In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤150ms |
≤300ms |
≤150ms |
≤300ms |
≤300ms |
≤300ms |
|
Delay-on de-energisation |
≤30ms |
≤30ms |
≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s) |
≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s) |
≤30ms |
≤30ms (instantaneous);- |
≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(delayed, factory set as 5s) |
|
Recovery time |
≤100ms |
≤100ms |
≤100ms |
≤100ms |
≤500ms |
≤100ms |
≤100ms |
|
Supply short interruption |
20ms |
20ms |
20ms |
20ms |
20ms |
20ms |
20ms |
|
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
|
Vibration |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
|
Relative humidity |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
|
Elevation |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
|
Overvoltage category |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅱ |
Ⅱ |
Ⅱ |
|
Pollution degree |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|
Rated insulation voltage |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
|
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
4000V (1.2/50us) |
4000V (1.2/50us) |
|
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
|
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
|
Safety integrity level |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
|
Performance level |
PLe |
PLe |
PLe |
PLe |
PLe |
PLe |
PLe |
|
Category |
Block Diagram of E-Stop Button, Safety Gate Safety Relay
Typical Applications of E-Stop Button, Safety Gate Safety Relay
Chenzhumanufactures the most reliable interface product for safety automation system. We are here to help your device run more safely. Here you can not only get world-class products, but also outstanding service for safety and automation system.
Send product request
Other supplier products
| Network SPD | The network surge protection device, also called ethernet cable surge protector, protects a data line, including computer network signals, communic... | |
| 20KA AC Power SPD | SPD for AC power; 220VAC, TN system, Single phase; In(8/20us): 10kA/phase, Imax: 20kA/phase; hot-pluggable; fault indication. Features & Adv... | |
| GS8500-EX Series Intrinsic Safety Barrier | GS8500-EX Series Intrinsic Barrier GS8500-EX range functional safety isolated barriers are CHENZHU's hit products, which obtained the first IECEx,... | |
| Safety Relay | SHANGHAI CHENZHU INSTRUMENT CO., LTD. is a very established provider that specialises in safety and automation system. We have over 24 years of exp... | |
| CZ2000 Series Signal Conditioner | CZ2000 analog signal isolator, analog voltage isolator CZ2000 range voltage signal conditioneruse high-efficiency electromagnetic isolation techno... |
Same products
| Microcrystalline wax used for rubber plastic processing and modification | Seller: Syntop chemical Co.,Ltd. | Microcrystalline wax has a wide range of industrial applications, primarily in the areas of rubbe... | |
| Microcrystalline wax 80A used for lubrication and demolding | Seller: Syntop chemical Co.,Ltd. | The core industrial applications of microcrystalline wax 80A are primarily focused on rubber prot... | |
| Tyvek Flat Roll Pouch | Seller: Hopeway AMD | Tyvek Flat Roll Pouch is designed for professional sterilization packaging, offering clean handli... | |
| Industrial Warehouse Ceiling Fans | Seller: Hebei Windmax Power Technology Co., Ltd. | Industrial Warehouse Ceiling Fans Industrial Warehouse Ceiling Fans for Warehouses, Logis... | |
| HVLS Ceiling Fan for Railway Station | Seller: Hebei Windmax Power Technology Co., Ltd. | HVLS Ceiling Fan for Railway Station for Railway Station All units are CE-certified, manufa... |