GF6018A CLAMP TYPE MULTIMETER CALIBRATOR

This GF6018A high precision multi-product calibrator is compliance with national verification regulation: JJG124-2005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05% single-phase standard AC/DC voltage and current source, can verify level 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter & clamp meter. The source signals by using DSP and 16-bit high-speed A/D converters of controllable sine wave, the distorted wave signal source. Multifunction calibrator GF6018A is designed as universal calibration tool for electrical calibration laboratories.

The GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected with PC to control, become automatic verification system. It has precise interface and multi-functions including verification, storage and query. The GF6018A multimeter calibrator adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics. It fully meets ISO17025 laboratory standards and is a good ideal test equipment for electrical engineers.

PARAMETERS

Electrical parameters
Power supply Single phase AC 220V±10% or 110V±10%, 50/60HzAC
AC Voltage output
range 200mV, 400mV, 2000mV, 4000mV,
20V, 100V, 200V, 500V, 1000V; max 1050V
Range 20V-1000V Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 200mV-4000mV Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS (1000V not included)
Fineness 5×10-5
AC Current Output
Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A; max 24A
Range 0.2A-20A Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 2mA-40mA Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS
Fineness 5×10-5
Frequency Output
Range 45-65Hz
Fineness 0.001Hz
Accuracy 0.002Hz
Harmonic Wave
Times 2-31
Extent 0-20%
Each harmonic phase fineness 0.01·N (N is harmonic order)
DC voltage output
Range 200mV, 400mV, 2000mV, 4000mV,
20V, 40V, 100V, 200V, 400V, 1000V; max 1050V
Load capacity 20W
Adjustable range 0-110% FS (1000V not included)
Adjustable fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.03%RD+0.02%FS)
Ripple wave ≤1% FS
DC current output
Range 20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A; max 22A
Load capacity 20W
Adjustable Range 0-110% FS (1000V not included)
Adjustable Fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.06%RD+0.04%FS)
Ripple wave ≤1% FS
Resistance box
Range 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10 kΩ, 20kΩ, 50KΩ, 100kΩ, 200kΩ, 500kΩ, 1MΩ, 2MΩ, 5MΩ, 10MΩ, 20MΩ
Fineness 0.02%
Adjustable Range 0-100%FS
Accuracy ±(0.3%RD+0.2%FS)
Clamp meter range
200A Accuracy ±0.2%
600A Accuracy ±0.5%
1000A Accuracy ±1%
Dot frequency square wave output
Range 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
Square wave amplitude 4.5V
Setting accuracy 5×10-5
Communication Port
Communication Port RS232, USB
Standard
Standard JJG124-2005; JJF1587-2016; IEC61010, IEC 61000, IEC 61326
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP20
Declaration of conformity CE, CNAS certified
Mechanical parameters
Dimension (L×W×H) (mm) 440x360x160
Weight (kg) 12
Environmental conditions
Operating temperature 20°C±10°C
Storage conditions -30°C to 60°C
Relative humidity ≤85%RH
(1) FS means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.


Send product request

To: 782364
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Q8A2:high sensitivity 0.1% permalloy core 10A AC current clamp CT
Q8A2:high sensitivity 0.1% permalloy core 10A AC current clamp CT The model Q8A2 permalloy core ac current clamp ct with high accuracy up to 0.1% has been designed for use with energy meter tester, multimeters, re...
XQ20:high precision 200A AC MINI split core clamp on current sensor
XQ20:high precision 200A AC MINI split core clamp on current sensor The model XQ20 clamp on current sensor is suitable for 200A cable online measurement.It output 0-200mA or 0-100mA AC signal for measuring and analy...
Q125B:cable type 3000A AC current sensor clamp with 5A output
Q125B:cable type 3000A AC current sensor clamp with 5A output The Q125B current sensor clamp is a high performance AC Current clamp with excellent transformation and low phase shift. It is widely applied in el...
P8:wholesale economic type 5A AC current clamp CT
P8:wholesale economic type 5A AC current clamp CT This current clamp ct uses a special magnetic core to provide higher accuracy and lower phase shift. The P8 Series AC current clamp ct is a cheap a...
Q13: MA output 100A AC clamp on current probe
Q13: MA output 100A AC clamp on current probe The Q13 clamp on current probe is a high accuracy mini probe for measurements to 120A AC.It can output 1mA/A, 1mV/A or 10mV/A etc. The Q13 Series c...
All supplier products

Same products

GF6018A CLAMP TYPE MULTIMETER CALIBRATOR
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR Seller: 782364 This GF6018A high precision multi-product calibrator is compliance with national verification reg...
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR Seller: 782364 DESCRIPTIONThe GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected w...
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR Seller: 782364 This GF6018A high precision multi-product calibrator is compliance with national verification reg...
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR Seller: 782364 APPLICATION ■ Power plant; ■ Universities; ■ Panel manufacturer; ■ Research institutes; ■ Electr...
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR Seller: 782364 This GF6018A high precision multi-product calibrator is compliance with national verification reg...